Robert J. Kroeze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert J. Kroeze has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
A. J. van der Veen
Department of Physics and Medical Technology, VU University Medical Center, Amsterdam, The Netherlands
1 shared publicationB. J. van Royen
Department of Orthopaedic Surgery, VU University Medical Center, Amsterdam, The Netherlands
1 shared publicationBarend J. van Royen
VU University Medical Center
1 shared publicationBert van Rietbergen
Eindhoven University of Technology
1 shared publicationM. N. Helder
Department of Orthopaedic Surgery, VU University Medical Center, Amsterdam, The Netherlands
1 shared publication- Marco N. Helder
VU University Medical Center
1 shared publication
Latest Publications
- 25 November 2014
- Published by Springer Nature in European Spine Journal
- Vol. 24 (5) , 1031-1042
Spinal fusion using adipose stem cells seeded on a radiolucent cage filler: a feasibility study of a single surgical procedure in goats
To assess the feasibility of a one-step surgical concept, employing adipose stem cells (ASCs) and a novel degradable radiolucent cage filler (poly-L-lactide-co-caprolactone; PLCL), within polyetheretherketone cages in a stand-alone caprine spinal fusion model. A double-level fusion study was performed in 36 goats. Four cage filler groups were defined: (i) acellular PLCL, (ii) PLCL + SVF (freshly harvested stromal vascular fraction highly enriched in ASCs); (iii) PLCL + ASCs (cultured to homogeneity); and (iv) autologous iliac crest bone graft (ABG). Fusion was assessed after 3 and 6 months by radiography, micro-CT, biomechanics, and biochemical analysis of tissue formed inside the cage after 6 months. No adverse effects were observed in all groups. After 3 months, similar and low fusion rates were found. Segmental stability did not differ between groups in all tested directions. Micro-CT imaging revealed significantly higher amounts of mineralized tissue in the ABG group compared to all others. After 6 months, interbody fusion rates were: PLCL 53%, SVF 30%, ASC 43% and ABG 63%. A trend towards higher mineralized tissue content was found for the ABG group. Biochemical and biomechanical analyses revealed equal maturity of collagen cross-links and similar segmental stability between all groups. This study demonstrates the technical feasibility and safety of the one-step surgical procedure for spinal fusion for the first time. The radiolucent PLCL scaffold allowed in vivo monitoring of bone formation using plain radiography. Addition of stem cells to the PLCL scaffolds did not result in adverse effects, but did not enhance the rate and number of interbody fusions under the current conditions. A trend towards superior results with ABG was found. Further research is warranted to optimize the spinal fusion model for proper evaluation of both PLCL and stem cell therap
- 25 November 2014
- Published by Springer Nature in European Spine Journal
- Vol. 24 (5) , 1031-1042
Spinal fusion using adipose stem cells seeded on a radiolucent cage filler: a feasibility study of a single surgical procedure in goats
To assess the feasibility of a one-step surgical concept, employing adipose stem cells (ASCs) and a novel degradable radiolucent cage filler (poly-L-lactide-co-caprolactone; PLCL), within polyetheretherketone cages in a stand-alone caprine spinal fusion model. A double-level fusion study was performed in 36 goats. Four cage filler groups were defined: (i) acellular PLCL, (ii) PLCL + SVF (freshly harvested stromal vascular fraction highly enriched in ASCs); (iii) PLCL + ASCs (cultured to homogeneity); and (iv) autologous iliac crest bone graft (ABG). Fusion was assessed after 3 and 6 months by radiography, micro-CT, biomechanics, and biochemical analysis of tissue formed inside the cage after 6 months. No adverse effects were observed in all groups. After 3 months, similar and low fusion rates were found. Segmental stability did not differ between groups in all tested directions. Micro-CT imaging revealed significantly higher amounts of mineralized tissue in the ABG group compared to all others. After 6 months, interbody fusion rates were: PLCL 53%, SVF 30%, ASC 43% and ABG 63%. A trend towards higher mineralized tissue content was found for the ABG group. Biochemical and biomechanical analyses revealed equal maturity of collagen cross-links and similar segmental stability between all groups. This study demonstrates the technical feasibility and safety of the one-step surgical procedure for spinal fusion for the first time. The radiolucent PLCL scaffold allowed in vivo monitoring of bone formation using plain radiography. Addition of stem cells to the PLCL scaffolds did not result in adverse effects, but did not enhance the rate and number of interbody fusions under the current conditions. A trend towards superior results with ABG was found. Further research is warranted to optimize the spinal fusion model for proper evaluation of both PLCL and stem cell therap
- 17 September 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (12) , 2731-2739
Relation between radiological assessment and biomechanical stability of lumbar interbody fusion in a large animal model
Purpose To relate the progress of vertebral segmental stability after interbody fusion surgery with radiological assessment of spinal fusion. Methods Twenty goats received double-level interbody fusion and were followed for a period of 3, 6 and 12 months. After killing, interbody fusion was assessed radiographically by two independent observers. Subsequently, the lumbar spines were subjected to four-point bending and rotational deformation, assessed with an optoelectronic 3D movement registration system. In addition, four caprine lumbar spines were analysed in both the native situation and after the insertion of a cage device, as to mimic the direct post-surgical situation. The range of motion (ROM) in flexion/extension, lateral bending and axial rotation was analysed ex vivo using a multi-segment testing system. Results Significant reduction in ROM in the operated segments was already achieved with moderate bone ingrowth in flexion/extension (71 % reduction in ROM) and with only limited bone ingrowth in lateral bending (71 % reduction in ROM) compared to the post-surgical situation. The presence of a sentinel sign always resulted in a stable vertebral segment in both flexion/extension and lateral bending. For axial rotation, the ROM was already limited in both native and cage inserted situations, resulting in non-significant differences for all radiographic scores. Discussion In vivo vertebral segment stability, defined as a significant reduction in ROM, is achieved in an early stage of spinal fusion, well before a radiological bony fusion between the vertebrae can be observed. Therefore, plain radiography underestimates vertebral segment stability.
- 17 September 2013
- Published by Springer Nature in European Spine Journal
- Vol. 22 (12) , 2731-2739
Relation between radiological assessment and biomechanical stability of lumbar interbody fusion in a large animal model
Purpose To relate the progress of vertebral segmental stability after interbody fusion surgery with radiological assessment of spinal fusion. Methods Twenty goats received double-level interbody fusion and were followed for a period of 3, 6 and 12 months. After killing, interbody fusion was assessed radiographically by two independent observers. Subsequently, the lumbar spines were subjected to four-point bending and rotational deformation, assessed with an optoelectronic 3D movement registration system. In addition, four caprine lumbar spines were analysed in both the native situation and after the insertion of a cage device, as to mimic the direct post-surgical situation. The range of motion (ROM) in flexion/extension, lateral bending and axial rotation was analysed ex vivo using a multi-segment testing system. Results Significant reduction in ROM in the operated segments was already achieved with moderate bone ingrowth in flexion/extension (71 % reduction in ROM) and with only limited bone ingrowth in lateral bending (71 % reduction in ROM) compared to the post-surgical situation. The presence of a sentinel sign always resulted in a stable vertebral segment in both flexion/extension and lateral bending. For axial rotation, the ROM was already limited in both native and cage inserted situations, resulting in non-significant differences for all radiographic scores. Discussion In vivo vertebral segment stability, defined as a significant reduction in ROM, is achieved in an early stage of spinal fusion, well before a radiological bony fusion between the vertebrae can be observed. Therefore, plain radiography underestimates vertebral segment stability.