Rachel K. Surowiec
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Rachel K. Surowiec has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Charles P. Ho
Steadman Philippon Research Institute, Vail, CO, USA
3 shared publications - Erin P. Lucas
Steadman Philippon Research Institute, Vail, CO, United States
2 shared publications - Adam William Anz
Andrews Research & Education Foundation, Gulf Breeze, Florida, USA
1 shared publication Benjamin M. Petre
The Steadman Clinic Vail CO USA
1 shared publicationEric K. Fitzcharles
Steadman Philippon Research Institute 181 W Meadow Dr, Suite 1000 81657 Vail CO USA
1 shared publication- Eric K. Fitzcharles
Steadman Philippon Research Institute, Vail, CO, United States
1 shared publication
Latest Publications
- 1 May 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (5) , 801-805
MRI T2 mapping of the asymptomatic supraspinatus tendon by age and imaging plane using clinically relevant subregions
- 1 May 2014
- Published by Elsevier in European Journal of Radiology
- Vol. 83 (5) , 801-805
MRI T2 mapping of the asymptomatic supraspinatus tendon by age and imaging plane using clinically relevant subregions
- 24 November 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (6) , 1404-1414
T2 values of articular cartilage in clinically relevant subregions of the asymptomatic knee
Purpose: In order for T2 mapping to become more clinically applicable, reproducible subregions and standardized T2 parameters must be defined. This study sought to: (1) define clinically relevant subregions of knee cartilage using bone landmarks identifiable on both MR images and during arthroscopy and (2) determine healthy T2 values and T2 texture parameters within these subregions.Methods: Twenty‐five asymptomatic volunteers (age 18–35) were evaluated with a sagittal T2 mapping sequence. Manual segmentation was performed by three raters, and cartilage was divided into twenty‐one subregions modified from the International Cartilage Repair Society Articular Cartilage Mapping System. Mean T2 values and texture parameters (entropy, variance, contrast, homogeneity) were recorded for each subregion, and inter‐rater and intra‐rater reliability was assessed.Results: The central regions of the condyles had significantly higher T2 values than the posterior regions (P < 0.05) and higher variance than the posterior region on the medial side (P < 0.001). The central trochlea had significantly greater T2 values than the anterior and posterior condyles. The central lateral plateau had lower T2 values, lower variance, higher homogeneity, and lower contrast than nearly all subregions in the tibia. The central patellar regions had higher entropy than the superior and inferior regions (each P ≤ 0.001). Repeatability was good to excellent for all subregions.Conclusion: Significant differences in mean T2 values and texture parameters were found between subregions in this carefully selected asymptomatic population, which suggest that there is normal variation of T2 values within the knee joint. The clinically relevant subregions were found to be robust as demonstrated by the overall high repeatability.
- 24 November 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (6) , 1404-1414
T2 values of articular cartilage in clinically relevant subregions of the asymptomatic knee
Purpose: In order for T2 mapping to become more clinically applicable, reproducible subregions and standardized T2 parameters must be defined. This study sought to: (1) define clinically relevant subregions of knee cartilage using bone landmarks identifiable on both MR images and during arthroscopy and (2) determine healthy T2 values and T2 texture parameters within these subregions.Methods: Twenty‐five asymptomatic volunteers (age 18–35) were evaluated with a sagittal T2 mapping sequence. Manual segmentation was performed by three raters, and cartilage was divided into twenty‐one subregions modified from the International Cartilage Repair Society Articular Cartilage Mapping System. Mean T2 values and texture parameters (entropy, variance, contrast, homogeneity) were recorded for each subregion, and inter‐rater and intra‐rater reliability was assessed.Results: The central regions of the condyles had significantly higher T2 values than the posterior regions (P < 0.05) and higher variance than the posterior region on the medial side (P < 0.001). The central trochlea had significantly greater T2 values than the anterior and posterior condyles. The central lateral plateau had lower T2 values, lower variance, higher homogeneity, and lower contrast than nearly all subregions in the tibia. The central patellar regions had higher entropy than the superior and inferior regions (each P ≤ 0.001). Repeatability was good to excellent for all subregions.Conclusion: Significant differences in mean T2 values and texture parameters were found between subregions in this carefully selected asymptomatic population, which suggest that there is normal variation of T2 values within the knee joint. The clinically relevant subregions were found to be robust as demonstrated by the overall high repeatability.
- 30 October 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (6) , 1385-1395
Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping
Purpose: Early diagnosis of cartilage degeneration and longitudinal tracking of cartilage health including repair following surgical intervention would benefit from the ability to detect and monitor changes of the articular cartilage non‐invasively and before gross morphological alterations appear.Methods: Quantitative MR imaging has shown promising results with various imaging biomarkers such as T2 mapping, T1 rho and dGEMRIC demonstrating sensitivity in the detection of biochemical alterations within tissues of interest. However, acquiring accurate and clinically valuable quantitative data has proven challenging, and the reproducibility of the quantitative mapping technique and its values are essential. Although T2 mapping has been the focus in this discussion, all quantitative mapping techniques are subject to the same issues including variability in the imaging protocol, unloading and exercise, analysis, scanner and coil, calculation methods, and segmentation and registration concerns.Results: The causes for variability between time points longitudinally in a patient, among patients, and among centres need to be understood further and the issues addressed.Conclusions: The potential clinical applications of quantitative mapping are vast, but, before the clinical community can take full advantage of this tool, it must be automated, standardized, validated, and have proven reproducibility prior to its implementation into the standard clinical care routine.
- 30 October 2013
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 22 (6) , 1385-1395
Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping
Purpose: Early diagnosis of cartilage degeneration and longitudinal tracking of cartilage health including repair following surgical intervention would benefit from the ability to detect and monitor changes of the articular cartilage non‐invasively and before gross morphological alterations appear.Methods: Quantitative MR imaging has shown promising results with various imaging biomarkers such as T2 mapping, T1 rho and dGEMRIC demonstrating sensitivity in the detection of biochemical alterations within tissues of interest. However, acquiring accurate and clinically valuable quantitative data has proven challenging, and the reproducibility of the quantitative mapping technique and its values are essential. Although T2 mapping has been the focus in this discussion, all quantitative mapping techniques are subject to the same issues including variability in the imaging protocol, unloading and exercise, analysis, scanner and coil, calculation methods, and segmentation and registration concerns.Results: The causes for variability between time points longitudinally in a patient, among patients, and among centres need to be understood further and the issues addressed.Conclusions: The potential clinical applications of quantitative mapping are vast, but, before the clinical community can take full advantage of this tool, it must be automated, standardized, validated, and have proven reproducibility prior to its implementation into the standard clinical care routine.