Sebastian Valet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sebastian Valet has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Weisse
Empa, Swiss Fed Labs Mat Sci & Technol, Lab Mech Syst Engn, Uberlandstr 129, CH-8600 Dubendorf, Switzerland
2 shared publications - Giovanni Pietro Terrasi
Empa, Swiss Federal Laboratories for Materials Science and Technology
2 shared publications - Adrian Zurbuchen
School of Biomedical and Precision Engineering, University of Bern, Bern, Switzerland
1 shared publication - Andreas Haeberlin
Department of Cardiology Inselspital, University Hospital Bern, University of Bern Bern Switzerland
1 shared publication Beatrice Fischer
EMPA‐Lab Swiss Federal Laboratories for Materials Science and Technology Mechanical Systems Engineering Duebendorf Switzerland
1 shared publicationBernhard Weisse
EMPA‐Lab Swiss Federal Laboratories for Materials Science and Technology Mechanical Systems Engineering Duebendorf Switzerland
1 shared publication
Latest Publications
- Open Access
- 26 October 2021
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 20 (1) , 1-19
Temperature-dependent tensile properties of polyamide 12 for the use in percutaneous transluminal coronary angioplasty balloon catheters
Background: Percutaneous transluminal coronary angioplasty (PTCA) balloon catheters must withstand high pressures required for the lesion treatment, pushing loads during insertion, and pulling loads during withdrawal. These loads pose a challenge especially for polymeric tubular shafts with small cross sections. In order to enable new design innovations and to better understand the mechanics of current catheter technologies, the tensile properties of polyamide (PA) 12 were investigated. PA 12 dog bone specimens and medical PA 12 tubes were either stored at ambient temperature and humidity or conditioned in water, and subjected to tensile loads at different temperatures. In addition, the effect on the tensile properties of the necking process, a forming process to reduce the wall thickness of the tubes, was determined. Results: The tested tubes showed a reduction in both Young’s Modulus (− 41.5%) and yield stress (− 29.2%) compared to standardized specimens. Furthermore, an increase in temperature and water absorption softens the material and reduces the mechanical properties like the Young’s Modulus and the yield stress. It was found that the material strengthens during the necking process. Likely due to the orientation of the polymers chain molecules in load direction (Rösler et al., 2007), the Young’s Modulus of the material could be increased by 43.5%. Furthermore, the absence of a yield point after necking allows for a greater loading capacity of the material without unstable neck growth. Besides the strengthening, the ultimate strain is reduced by 50%. This indicates that the necking process induces plastic deformation. Conclusion: The investigation showed that the environmental conditions like temperature and humidity can influence mechanical properties. It could also be shown that pre-forming processes such as necking can enhance the mechanical properties, such as the Young’s Modulus, while reducing the wall thickness. These findings suggest possible further development of catheters with a small cross section and higher mechanical strength and highlight the importance to account for the targeted operating temperature during the design process.
- 26 October 2021
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 20 (1) , 1-19
Open AccessTemperature-dependent tensile properties of polyamide 12 for the use in percutaneous transluminal coronary angioplasty balloon catheters
Background: Percutaneous transluminal coronary angioplasty (PTCA) balloon catheters must withstand high pressures required for the lesion treatment, pushing loads during insertion, and pulling loads during withdrawal. These loads pose a challenge especially for polymeric tubular shafts with small cross sections. In order to enable new design innovations and to better understand the mechanics of current catheter technologies, the tensile properties of polyamide (PA) 12 were investigated. PA 12 dog bone specimens and medical PA 12 tubes were either stored at ambient temperature and humidity or conditioned in water, and subjected to tensile loads at different temperatures. In addition, the effect on the tensile properties of the necking process, a forming process to reduce the wall thickness of the tubes, was determined. Results: The tested tubes showed a reduction in both Young’s Modulus (− 41.5%) and yield stress (− 29.2%) compared to standardized specimens. Furthermore, an increase in temperature and water absorption softens the material and reduces the mechanical properties like the Young’s Modulus and the yield stress. It was found that the material strengthens during the necking process. Likely due to the orientation of the polymers chain molecules in load direction (Rösler et al., 2007), the Young’s Modulus of the material could be increased by 43.5%. Furthermore, the absence of a yield point after necking allows for a greater loading capacity of the material without unstable neck growth. Besides the strengthening, the ultimate strain is reduced by 50%. This indicates that the necking process induces plastic deformation. Conclusion: The investigation showed that the environmental conditions like temperature and humidity can influence mechanical properties. It could also be shown that pre-forming processes such as necking can enhance the mechanical properties, such as the Young’s Modulus, while reducing the wall thickness. These findings suggest possible further development of catheters with a small cross section and higher mechanical strength and highlight the importance to account for the targeted operating temperature during the design process.
- 12 May 2016
- Published by Wiley in Arthroscopy
- Vol. 32 (10) , 1985-1992
Mechanical Effects of Heat Exposure From a Bipolar Radiofrequency Probe on Suture Under Simulated Arthroscopic Conditions
Purpose: To determine conditions for the safe use of radiofrequency (RF) tissue ablation probes that avoid damaging suture material. Methods: Four sutures made of 3 different materials commonly used in arthroscopic procedures were analyzed in a saline bath related to effects of RF‐produced heat by proximity, duration, and intensity settings measuring burn‐through time and ultimate load to failure. The parameters tested were electrode‐to‐suture distance, power setting, and the presence of tendon tissue or metallic anchor eyelets. Outcome variables were the burn‐through time and the ultimate failure load of differently treated suture samples. Results: Mean burn‐through time for suture in direct contact with the RF probe ranged from 57.2 to 14.7 seconds for ultra‐high‐molecular‐weight polyethylene (UHMWPE) sutures, 1.1 seconds for polydioxanone suture, and 0.8 seconds for polyethylene terephthalate suture. One of the UHMWPE sutures was capable of withstanding 3 seconds of direct contact with the RF probe without any compromise in tensile strength. No suture material tested had any mechanical change as long as the RF probe was kept 1 mm from the suture. Conclusions: Heat from RF tissue ablation probes can cause undetected damage. High‐strength UHMWPE sutures were less sensitive to an RF treatment than polyester sutures. The use of different test substrates did not significantly influence the burn through time. Clinical Relevance: Heat from RF probes can damage some suture material if direct contact is made even briefly. The use of RF devices may be safe for the suture when a distance between probe and suture of >1 mm is maintained. Suture made from UHMWPE may tolerate up to 3 seconds of RF probe contact and not sustain significant damage. Surgeons must use great care when using RF devices in the vicinity of suture placement.
- 12 May 2016
- Published by Wiley in Arthroscopy
- Vol. 32 (10) , 1985-1992
Mechanical Effects of Heat Exposure From a Bipolar Radiofrequency Probe on Suture Under Simulated Arthroscopic Conditions
Purpose: To determine conditions for the safe use of radiofrequency (RF) tissue ablation probes that avoid damaging suture material. Methods: Four sutures made of 3 different materials commonly used in arthroscopic procedures were analyzed in a saline bath related to effects of RF‐produced heat by proximity, duration, and intensity settings measuring burn‐through time and ultimate load to failure. The parameters tested were electrode‐to‐suture distance, power setting, and the presence of tendon tissue or metallic anchor eyelets. Outcome variables were the burn‐through time and the ultimate failure load of differently treated suture samples. Results: Mean burn‐through time for suture in direct contact with the RF probe ranged from 57.2 to 14.7 seconds for ultra‐high‐molecular‐weight polyethylene (UHMWPE) sutures, 1.1 seconds for polydioxanone suture, and 0.8 seconds for polyethylene terephthalate suture. One of the UHMWPE sutures was capable of withstanding 3 seconds of direct contact with the RF probe without any compromise in tensile strength. No suture material tested had any mechanical change as long as the RF probe was kept 1 mm from the suture. Conclusions: Heat from RF tissue ablation probes can cause undetected damage. High‐strength UHMWPE sutures were less sensitive to an RF treatment than polyester sutures. The use of different test substrates did not significantly influence the burn through time. Clinical Relevance: Heat from RF probes can damage some suture material if direct contact is made even briefly. The use of RF devices may be safe for the suture when a distance between probe and suture of >1 mm is maintained. Suture made from UHMWPE may tolerate up to 3 seconds of RF probe contact and not sustain significant damage. Surgeons must use great care when using RF devices in the vicinity of suture placement.
- Open Access
CFRP-Strengthening and Long-Term Performance of Fatigue Critical Welds of a Steel Box Girder
Empa’s research efforts in the 1990s provided evidence that a considerable increase of the fatigue strength of welded aluminum beams can be achieved by externally bonding pultruded carbon fiber reinforced polymer (CFRP) laminates using rubber-toughened epoxies over the fatigue-weak welding zone on their tensile flange. The reinforcing effect obtained is determined by the stiffness of the unidirectional CFRP laminate which has twice the elastic modulus of aluminum. One can therefore easily follow that an unstressed CFRP laminate reinforcement of welded beams made of steel will not lead to a substantial increase in fatigue strength of the steel structure. This consideration led to the idea of prestressing an external reinforcement of the welded zone. The present investigation describes experimental studies to identify the adhesive system suitable for achieving high creep and fatigue strength of the prestressed CFRP patch. Experimental results (Wöhler-fields) of shear-lap-specimens and welded steel beams reinforced with prestressed CFRP laminates are presented. The paper concludes by presenting a field application, the reinforcement of a steel pendulum by adhesively bonded prestressed CFRP laminates to the tensile flanges of the welded box girder. Inspections carried out periodically on this structure revealed neither prestress losses nor crack initiation after nine years of service.
Open AccessCFRP-Strengthening and Long-Term Performance of Fatigue Critical Welds of a Steel Box Girder
Empa’s research efforts in the 1990s provided evidence that a considerable increase of the fatigue strength of welded aluminum beams can be achieved by externally bonding pultruded carbon fiber reinforced polymer (CFRP) laminates using rubber-toughened epoxies over the fatigue-weak welding zone on their tensile flange. The reinforcing effect obtained is determined by the stiffness of the unidirectional CFRP laminate which has twice the elastic modulus of aluminum. One can therefore easily follow that an unstressed CFRP laminate reinforcement of welded beams made of steel will not lead to a substantial increase in fatigue strength of the steel structure. This consideration led to the idea of prestressing an external reinforcement of the welded zone. The present investigation describes experimental studies to identify the adhesive system suitable for achieving high creep and fatigue strength of the prestressed CFRP patch. Experimental results (Wöhler-fields) of shear-lap-specimens and welded steel beams reinforced with prestressed CFRP laminates are presented. The paper concludes by presenting a field application, the reinforcement of a steel pendulum by adhesively bonded prestressed CFRP laminates to the tensile flanges of the welded box girder. Inspections carried out periodically on this structure revealed neither prestress losses nor crack initiation after nine years of service.
- Open Access
- 1 January 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 38
Are asymmetric metal markings on the cone surface of ceramic femoral heads an indication of entrapped debris?
The probability of in vivo failure of ceramic hip joint implants is very low (0.004-0.05%). In addition to material flaws and overloading, improper handling during implantation can induce fractures of the ceramic ball head in the long term. Identifying the causes of an in vivo fracture contributes to improved understanding and potentially to further reduction of the fracture probability for patients. Asymmetric metal markings on the cone surface of in vivo ball head fractures have been reported. The question, therefore, is whether asymmetric loading is the sole cause or whether additional factors, specifically contamination entrapped in the taper fit, also contribute or are even the main cause. The influence of the asymmetric physiological load configuration on resulting metal markings in the cone surface of an alumina femoral ball head with and without biological contaminants was investigated. Static and cyclic tests on ball heads were carried out in a load configuration of 0° (axisymmetric) and 40° in a physiological environment. The analysis of the metal marking was carried out to gain a better understanding of the processes that contribute to the generation of metal marking. Fractography was carried out to determine the fracture initiation of failed ball heads. Different types and sizes of residuals entrapped in the conical surface are shown to yield strongly asymmetric metal marking patterns. All heads tested without contaminants exhibited an almost homogenous distribution of residual metal markings around the circumference of the ceramic cone surface at the proximal end of the bore hole. The failure of ball heads that contained entrapped contaminants revealed a common fracture pattern. The site of fracture initiation on two of the failed heads was in the entrance region of the bore hole on the superior half of the head. Asymmetric metal markings observed on the ball heads tested in this investigation are most probably caused by the presence of contaminants entrapped in the taper fit. Homogenous metal mark distributions around the circumference indicate proper assembly of the ball head without entrapped contaminants. It should, however, be noted that different taper designs may possibly result in different marking patterns.
- 1 January 2014
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 13 (1) , 38
Open AccessAre asymmetric metal markings on the cone surface of ceramic femoral heads an indication of entrapped debris?
The probability of in vivo failure of ceramic hip joint implants is very low (0.004-0.05%). In addition to material flaws and overloading, improper handling during implantation can induce fractures of the ceramic ball head in the long term. Identifying the causes of an in vivo fracture contributes to improved understanding and potentially to further reduction of the fracture probability for patients. Asymmetric metal markings on the cone surface of in vivo ball head fractures have been reported. The question, therefore, is whether asymmetric loading is the sole cause or whether additional factors, specifically contamination entrapped in the taper fit, also contribute or are even the main cause. The influence of the asymmetric physiological load configuration on resulting metal markings in the cone surface of an alumina femoral ball head with and without biological contaminants was investigated. Static and cyclic tests on ball heads were carried out in a load configuration of 0° (axisymmetric) and 40° in a physiological environment. The analysis of the metal marking was carried out to gain a better understanding of the processes that contribute to the generation of metal marking. Fractography was carried out to determine the fracture initiation of failed ball heads. Different types and sizes of residuals entrapped in the conical surface are shown to yield strongly asymmetric metal marking patterns. All heads tested without contaminants exhibited an almost homogenous distribution of residual metal markings around the circumference of the ceramic cone surface at the proximal end of the bore hole. The failure of ball heads that contained entrapped contaminants revealed a common fracture pattern. The site of fracture initiation on two of the failed heads was in the entrance region of the bore hole on the superior half of the head. Asymmetric metal markings observed on the ball heads tested in this investigation are most probably caused by the presence of contaminants entrapped in the taper fit. Homogenous metal mark distributions around the circumference indicate proper assembly of the ball head without entrapped contaminants. It should, however, be noted that different taper designs may possibly result in different marking patterns.
- 30 April 2013
- Published by Elsevier in Engineering Failure Analysis
- Vol. 35, 439-453
Accident caused by dynamic overloading of a ship mooring rope
- 30 April 2013
- Published by Elsevier in Engineering Failure Analysis
- Vol. 35, 439-453
Accident caused by dynamic overloading of a ship mooring rope