Jonas Schiffmann
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jonas Schiffmann has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Markus Graefen
Martini-Clinic, Prostate Cancer Center, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
4 shared publications - Pierre Tennstedt
Martini-Klinik Prostate Cancer Center, University Hospital Hamburg-Eppendorf, Hamburg, Germany
4 shared publications - Alexander Haese
Martini-Clinic, Prostate Cancer Center, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications - Katharina Boehm
Universitätsklinikum Carl-Gustav-Carus Dresden, Department of Urology, Technische Universität Dresden, Dresden, Germany
3 shared publications Pierre I. Karakiewicz
Cancer Prognostics and Health Outcomes Unit, University of Montreal Health Center, Montreal, Canada
3 shared publications- Thomas Steuber
Martini Clinic, Prostate Cancer Center Hamburg-Eppendorf, Hamburg, Germany
3 shared publications
Latest Publications
- 2 March 2018
- Published by Springer Nature in World Journal of Urology
- Vol. 36 (7) , 1067-1072
Obesity paradox in prostate cancer: increased body mass index was associated with decreased risk of metastases after surgery in 13,667 patients
Obesity might negatively affect prostate cancer (PCa) outcomes. However, evidence according to the associations between obesity and metastases-free survival after radical prostatectomy (RP) is still inconsistent.
- 2 March 2018
- Published by Springer Nature in World Journal of Urology
- Vol. 36 (7) , 1067-1072
Obesity paradox in prostate cancer: increased body mass index was associated with decreased risk of metastases after surgery in 13,667 patients
Obesity might negatively affect prostate cancer (PCa) outcomes. However, evidence according to the associations between obesity and metastases-free survival after radical prostatectomy (RP) is still inconsistent.
- 1 December 2016
- Published by Edizioni Minerva Medica in Minerva Urology and Nephrology
- Vol. 69 (1) , 69-75
Ten-year experience of robot-assisted radical prostatectomy: the road from cherry-picking to standard procedure
Article: Ten-year experience of robot-assisted radical prostatectomy: the road from cherry-picking to standard procedure - Minerva Urologica e Nefrologica 2017 February;69(1):69-75 - Minerva Medica - Journals
- 1 December 2016
- Published by Edizioni Minerva Medica in Minerva Urology and Nephrology
- Vol. 69 (1) , 69-75
Ten-year experience of robot-assisted radical prostatectomy: the road from cherry-picking to standard procedure
Article: Ten-year experience of robot-assisted radical prostatectomy: the road from cherry-picking to standard procedure - Minerva Urologica e Nefrologica 2017 February;69(1):69-75 - Minerva Medica - Journals
- 28 July 2015
- Published by Springer Nature in World Journal of Urology
- Vol. 34 (4) , 495-500
True targeting-derived prostate biopsy: HistoScanning™ remained inadequate despite advanced technical efforts
Purpose To verify the reliability of HistoScanning™-based, true targeting (TT)-derived prostate biopsy. Methods We relied on 40 patients suspicious for prostate cancer who underwent standard and TT-derived prostate biopsy. Sensitivity, specificity, positive predictive value, negative predictive value and the area under the curve (AUC) were assessed for the prediction of biopsy results per octant by HistoScanning™, using different HistoScanning™ signal volume cutoffs (>0, >0.2 and >0.5 ml). Results Overall, 319 octants were analyzed. Of those, 64 (20.1 %) harbored prostate cancer. According to different HistoScanning™ signal volume cutoffs (>0, >0.2 and >0.5 ml), the AUCs for predicting biopsy results were: 0.51, 0.51 and 0.53, respectively. Similarly, the sensitivity, specificity, positive predictive and negative predictive values were: 20.7, 78.2, 17.4 and 81.6 %; 20.7, 82.0, 20.3 and 82.3 %; and 12.1, 94.6, 33.3 and 82.9 %, respectively. Conclusions Prediction of biopsy results based on HistoScanning™ signals and TT-derived biopsies was unreliable. Moreover, the AUC of TT-derived biopsies was low and did not improve when additional signal volume cutoffs were applied (>0.2 and >0.5 ml). We cannot recommend a variation of well-established biopsy standards or reduction in biopsy cores based on HistoScanning™ signals.
- 28 July 2015
- Published by Springer Nature in World Journal of Urology
- Vol. 34 (4) , 495-500
True targeting-derived prostate biopsy: HistoScanning™ remained inadequate despite advanced technical efforts
Purpose To verify the reliability of HistoScanning™-based, true targeting (TT)-derived prostate biopsy. Methods We relied on 40 patients suspicious for prostate cancer who underwent standard and TT-derived prostate biopsy. Sensitivity, specificity, positive predictive value, negative predictive value and the area under the curve (AUC) were assessed for the prediction of biopsy results per octant by HistoScanning™, using different HistoScanning™ signal volume cutoffs (>0, >0.2 and >0.5 ml). Results Overall, 319 octants were analyzed. Of those, 64 (20.1 %) harbored prostate cancer. According to different HistoScanning™ signal volume cutoffs (>0, >0.2 and >0.5 ml), the AUCs for predicting biopsy results were: 0.51, 0.51 and 0.53, respectively. Similarly, the sensitivity, specificity, positive predictive and negative predictive values were: 20.7, 78.2, 17.4 and 81.6 %; 20.7, 82.0, 20.3 and 82.3 %; and 12.1, 94.6, 33.3 and 82.9 %, respectively. Conclusions Prediction of biopsy results based on HistoScanning™ signals and TT-derived biopsies was unreliable. Moreover, the AUC of TT-derived biopsies was low and did not improve when additional signal volume cutoffs were applied (>0.2 and >0.5 ml). We cannot recommend a variation of well-established biopsy standards or reduction in biopsy cores based on HistoScanning™ signals.
- 1 March 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (7_suppl) , 153
Redefining postprostatectomy biochemical progression: The significance of a PSA cutoff below 0.2 ng/ml—Results from two retrospective series with and without salvage radiotherapy.
153 Background: Biochemical recurrence (BCR) after radical prostatectomy (RP) is usually defined at a PSA >0.2 ng/ml. BCR may precede clinical progression by years. Though salvage radiotherapy (SRT) is recommend to be initiated at PSA 0.2 ng/ml) within a median time of 7 months. Subsequent PSA rise to >0.3, >0.4, and >0.6 ng/ml was recorded in 174 (58%), 123 (41%), and 24 (8%) men, respectively. Twenty-four (8%) men developed metastases. In cohort 2, 112 men received SRT at PSA between 0.03 and 0.2 ng/ml, and 86 at 0.2-0.499 ng/ml. The latter group, had a poorer 10-years BCR-free Kaplan-Meier rate, 43% vs. 66% (p=0.051). Together with pT0.1 ng/ml after RP will subsequently progress to PSA >0.2 ng/ml. Improved progression free survival can be achieved, if SRT is administered at a PSA
- 1 March 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (7_suppl) , 153
Redefining postprostatectomy biochemical progression: The significance of a PSA cutoff below 0.2 ng/ml—Results from two retrospective series with and without salvage radiotherapy.
153 Background: Biochemical recurrence (BCR) after radical prostatectomy (RP) is usually defined at a PSA >0.2 ng/ml. BCR may precede clinical progression by years. Though salvage radiotherapy (SRT) is recommend to be initiated at PSA 0.2 ng/ml) within a median time of 7 months. Subsequent PSA rise to >0.3, >0.4, and >0.6 ng/ml was recorded in 174 (58%), 123 (41%), and 24 (8%) men, respectively. Twenty-four (8%) men developed metastases. In cohort 2, 112 men received SRT at PSA between 0.03 and 0.2 ng/ml, and 86 at 0.2-0.499 ng/ml. The latter group, had a poorer 10-years BCR-free Kaplan-Meier rate, 43% vs. 66% (p=0.051). Together with pT0.1 ng/ml after RP will subsequently progress to PSA >0.2 ng/ml. Improved progression free survival can be achieved, if SRT is administered at a PSA
- 1 February 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (4) , 147
A feasible and time-efficient adaption of the neurosafe intraoperative frozen section technique to robotic-assisted radical prostatectomy.
147 Background: In robotic-assisted radical prostatectomy (RARP) intraoperative frozen sections are often avoided due to suspected difficulties in harvesting the prostate during this procedure, loss in pneumoperitoneum, increased blood loss and lacking impact on functional outcome. We demonstrate the technique, feasibility and beneficial impact of our NeuroSAFE technique on the rate of nerve-sparing (NS) in RARP and analyse the oncological outcome. Methods: We analyzed 1,570 consecutive patients undergoing RARP from 2004 to 2012. NeuroSAFE was done in 1,178 pts. We compared OR-time, blood loss, frequency of nerve-sparing (NS) and PSM in non-NeuroSAFE versus NeuroSAFE-RARP. The prostate was intraoperatively harvested via an extension of the camera trocar incision without undocking the system. Instrument arms were not undocked. Blood spillage from the dorsal vein complex due to loss of pneumoperitoneum was avoided by upward traction on the transurethral catheter. After prostate removal, pneumoperitoneum was reestablished by closing the extended incision and repositioning of the optical trocar. NeuroSAFE-procedure consisted of intraoperative bilateral frozen sections covering the entire contact area of the prostate and the neurovascular bundles. Results: There was no significant difference in blood loss (253.5±204.4 ml vs. 265.8±246.7 ml, p=0.49) and OR-time. (220 min ± 51 vs. 224 min ± 64, p=0.22). No complications associated with specimen harvesting occurred. NS-rate increased significantly with vs. without NeuroSAFE (overall 97% vs. 81%, pT2 99% vs. 90%, pT3a 94% vs. 74%, pT3b 91% vs. 30). PSM rate dropped significantly with NeuroSAFE (overall 16% vs. 24%, pT2 8% vs. 15%, pT3a 22% vs. 39%, pT3b 49% vs. 67%, all p
- 1 February 2014
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 32 (4) , 147
A feasible and time-efficient adaption of the neurosafe intraoperative frozen section technique to robotic-assisted radical prostatectomy.
147 Background: In robotic-assisted radical prostatectomy (RARP) intraoperative frozen sections are often avoided due to suspected difficulties in harvesting the prostate during this procedure, loss in pneumoperitoneum, increased blood loss and lacking impact on functional outcome. We demonstrate the technique, feasibility and beneficial impact of our NeuroSAFE technique on the rate of nerve-sparing (NS) in RARP and analyse the oncological outcome. Methods: We analyzed 1,570 consecutive patients undergoing RARP from 2004 to 2012. NeuroSAFE was done in 1,178 pts. We compared OR-time, blood loss, frequency of nerve-sparing (NS) and PSM in non-NeuroSAFE versus NeuroSAFE-RARP. The prostate was intraoperatively harvested via an extension of the camera trocar incision without undocking the system. Instrument arms were not undocked. Blood spillage from the dorsal vein complex due to loss of pneumoperitoneum was avoided by upward traction on the transurethral catheter. After prostate removal, pneumoperitoneum was reestablished by closing the extended incision and repositioning of the optical trocar. NeuroSAFE-procedure consisted of intraoperative bilateral frozen sections covering the entire contact area of the prostate and the neurovascular bundles. Results: There was no significant difference in blood loss (253.5±204.4 ml vs. 265.8±246.7 ml, p=0.49) and OR-time. (220 min ± 51 vs. 224 min ± 64, p=0.22). No complications associated with specimen harvesting occurred. NS-rate increased significantly with vs. without NeuroSAFE (overall 97% vs. 81%, pT2 99% vs. 90%, pT3a 94% vs. 74%, pT3b 91% vs. 30). PSM rate dropped significantly with NeuroSAFE (overall 16% vs. 24%, pT2 8% vs. 15%, pT3a 22% vs. 39%, pT3b 49% vs. 67%, all p
- 24 November 2013
- Published by Springer Nature in World Journal of Urology
- Vol. 32 (4) , 939-944
Comparison of prostate cancer volume measured by HistoScanning™ and final histopathological results
HistoScanning™ (HS) is an ultrasound-based tissue characterization technique with encouraging results in the detection of prostate cancer (PCa). The aim of this study was to evaluate the accuracy of total tumor volume measured by HS (TVHS) in patients with PCa. In 148 patients with proven PCa, TVHS was measured prior to radical prostatectomy and compared with the total tumor volume in the final pathological report (TVP) using the rank-based spearman correlation test. Correlation was performed after stratification of the results by d’Amico risk categories, prostate volume, experience of HS examiner, distance of the ultrasound probe to the prostate (≤3.5 and >3.5 mm) and quality of initial HS. In addition, a re-analysis of HS data was performed by a single examiner and the TVHS from the unmodified HS data was acquired. TVP was approximately twofold higher compared to TVHS. Overall, there was no significant correlation (r s = −0.0083, p = 0.9) for the TVP and the TVHS. After adjusting for d’Amico risk categories, prostate volume, experience of examiner, distance of the ultrasound probe to the prostate and quality of initial HS, no significant correlation was found. After re-analyzing of all HS data by 1 examiner, the correlation remained not significant (r s = 0.039, p = 0.6). TVHS and TVP did not correlate in this cohort of patients. We cannot recommend the use of HS at least for imaging of the total tumor volume at this time. The controversial findings for prostate HS should initiate more studies to clarify these discrepancies.
- 24 November 2013
- Published by Springer Nature in World Journal of Urology
- Vol. 32 (4) , 939-944
Comparison of prostate cancer volume measured by HistoScanning™ and final histopathological results
HistoScanning™ (HS) is an ultrasound-based tissue characterization technique with encouraging results in the detection of prostate cancer (PCa). The aim of this study was to evaluate the accuracy of total tumor volume measured by HS (TVHS) in patients with PCa. In 148 patients with proven PCa, TVHS was measured prior to radical prostatectomy and compared with the total tumor volume in the final pathological report (TVP) using the rank-based spearman correlation test. Correlation was performed after stratification of the results by d’Amico risk categories, prostate volume, experience of HS examiner, distance of the ultrasound probe to the prostate (≤3.5 and >3.5 mm) and quality of initial HS. In addition, a re-analysis of HS data was performed by a single examiner and the TVHS from the unmodified HS data was acquired. TVP was approximately twofold higher compared to TVHS. Overall, there was no significant correlation (r s = −0.0083, p = 0.9) for the TVP and the TVHS. After adjusting for d’Amico risk categories, prostate volume, experience of examiner, distance of the ultrasound probe to the prostate and quality of initial HS, no significant correlation was found. After re-analyzing of all HS data by 1 examiner, the correlation remained not significant (r s = 0.039, p = 0.6). TVHS and TVP did not correlate in this cohort of patients. We cannot recommend the use of HS at least for imaging of the total tumor volume at this time. The controversial findings for prostate HS should initiate more studies to clarify these discrepancies.