Lizeth H. Sloot
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lizeth H. Sloot has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Jaap Harlaar
Department of Biomechanical Engineering, Delft University of Technology, 2628 CD Delft, The Netherlands
9 shared publications - Marjolein Margaretha van der Krogt
Department of Rehabilitation Medicine, Amsterdam UMC Location Vrije Universiteit Amsterdam, 1081 HV Amsterdam, The Netherlands
9 shared publications - Annemieke I. Buizer
Department of Rehabilitation Medicine, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
2 shared publications - Han Houdijk
Department of Human Movement Sciences, University Medical Center Groningen, University of Groningen, The Netherlands
2 shared publications J. Harlaar
2 shared publications- Carel Gerardus Maria Meskers
Rehabilitation Medicine, Amsterdam UMC Location Vrije Universiteit Amsterdam, De Boelelaan 1117, Amsterdam, 1081HV, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 1 July 2016
- Published by Wiley in Developmental Medicine & Child Neurology
- Vol. 59 (2) , 145-151
Motorized versus manual instrumented spasticity assessment in children with cerebral palsy
Aim: We compared the outcomes of manual and motorized instrumented ankle spasticity assessments in children with cerebral palsy (CP).Method: Ten children with spasticCP(three males, seven females; mean age 11y [standard deviation 3y], range 6–14y; Gross Motor Function Classification System levels I–III) were included. During motorized assessments, fast (100°/s) rotations were imposed around the ankle joint by a motor‐driven footplate; during manual assessments, rotations of comparable speed were applied by a therapist using a foot orthotic. Angular range of motion, maximum velocity, acceleration, work, and muscle activity (electromyography [EMG]) of the triceps surae and tibialis anterior were compared during passive muscle stretch between motorized and manual assessments. Both movement profiles were also compared toCPgait ankle movement profile.Results: The imposed movement profile differed between methods, with the motorized assessment reaching higher maximum acceleration. Despite equal maximum velocity, the triceps surae were more often activated in motorized assessments, with low agreement of 44% to 72% (κ≤0) forEMGonset occurrence between methods. The manually applied ankle velocity profile matched more closely with the gait profile.Interpretation: The differences in acceleration possibly account for the different muscle responses, which may suggest acceleration, rather than velocity‐dependency of the stretch reflex. Future prototypes of instrumented spasticity assessments should standardize movement profiles, preferably by developing profiles that mimic functional tasks such as walking.
- 1 July 2016
- Published by Wiley in Developmental Medicine & Child Neurology
- Vol. 59 (2) , 145-151
Open AccessMotorized versus manual instrumented spasticity assessment in children with cerebral palsy
Aim: We compared the outcomes of manual and motorized instrumented ankle spasticity assessments in children with cerebral palsy (CP).Method: Ten children with spasticCP(three males, seven females; mean age 11y [standard deviation 3y], range 6–14y; Gross Motor Function Classification System levels I–III) were included. During motorized assessments, fast (100°/s) rotations were imposed around the ankle joint by a motor‐driven footplate; during manual assessments, rotations of comparable speed were applied by a therapist using a foot orthotic. Angular range of motion, maximum velocity, acceleration, work, and muscle activity (electromyography [EMG]) of the triceps surae and tibialis anterior were compared during passive muscle stretch between motorized and manual assessments. Both movement profiles were also compared toCPgait ankle movement profile.Results: The imposed movement profile differed between methods, with the motorized assessment reaching higher maximum acceleration. Despite equal maximum velocity, the triceps surae were more often activated in motorized assessments, with low agreement of 44% to 72% (κ≤0) forEMGonset occurrence between methods. The manually applied ankle velocity profile matched more closely with the gait profile.Interpretation: The differences in acceleration possibly account for the different muscle responses, which may suggest acceleration, rather than velocity‐dependency of the stretch reflex. Future prototypes of instrumented spasticity assessments should standardize movement profiles, preferably by developing profiles that mimic functional tasks such as walking.
- 11 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (8) , 785-792
Optimal calibration of instrumented treadmills using an instrumented pole
Calibration of instrumented treadmills is imperative for accurate measurement of ground reaction forces and center of pressure (COP). A protocol using an instrumented pole has been shown to considerably increase force and COP accuracy. This study examined how this protocol can be further optimized to maximize accuracy, by varying the measurement time and number of spots, using nonlinear approaches to calculate the calibration matrix and by correcting for potential inhomogeneity in the distribution of COP errors across the treadmill's surface. The accuracy increased with addition of spots and correction for the inhomogeneous distribution across the belt surface, decreased with reduction of measurement time, and did not improve by including nonlinear terms. Most of these methods improved the overall accuracy only to a limited extent, suggesting that the maximal accuracy is approached given the treadmill's inherent mechanical limitations. However, both correction for position dependence of the accuracy as well as its optimization within the walking area are found to be valuable additions to the standard calibration process.
- 11 May 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (8) , 785-792
Optimal calibration of instrumented treadmills using an instrumented pole
Calibration of instrumented treadmills is imperative for accurate measurement of ground reaction forces and center of pressure (COP). A protocol using an instrumented pole has been shown to considerably increase force and COP accuracy. This study examined how this protocol can be further optimized to maximize accuracy, by varying the measurement time and number of spots, using nonlinear approaches to calculate the calibration matrix and by correcting for potential inhomogeneity in the distribution of COP errors across the treadmill's surface. The accuracy increased with addition of spots and correction for the inhomogeneous distribution across the belt surface, decreased with reduction of measurement time, and did not improve by including nonlinear terms. Most of these methods improved the overall accuracy only to a limited extent, suggesting that the maximal accuracy is approached given the treadmill's inherent mechanical limitations. However, both correction for position dependence of the accuracy as well as its optimization within the walking area are found to be valuable additions to the standard calibration process.
- Open Access
- 15 December 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (12) , e0144815
Can Treadmill Perturbations Evoke Stretch Reflexes in the Calf Muscles?
Disinhibition of reflexes is a problem amongst spastic patients, for it limits a smooth and efficient execution of motor functions during gait. Treadmill belt accelerations may potentially be used to measure reflexes during walking, i.e. by dorsal flexing the ankle and stretching the calf muscles, while decelerations show the modulation of reflexes during a reduction of sensory feedback. The aim of the current study was to examine if belt accelerations and decelerations of different intensities applied during the stance phase of treadmill walking can evoke reflexes in the gastrocnemius, soleus and tibialis anterior in healthy subjects. Muscle electromyography and joint kinematics were measured in 10 subjects. To determine whether stretch reflexes occurred, we assessed modelled musculo-tendon length and stretch velocity, the amount of muscle activity, as well as the incidence of bursts or depressions in muscle activity with their time delays, and co-contraction between agonist and antagonist muscle. Although the effect on the ankle angle was small with 2.8±1.0°, the perturbations caused clear changes in muscle length and stretch velocity relative to unperturbed walking. Stretched muscles showed an increasing incidence of bursts in muscle activity, which occurred after a reasonable electrophysiological time delay (163–191 ms). Their amplitude was related to the muscle stretch velocity and not related to co-contraction of the antagonist muscle. These effects increased with perturbation intensity. Shortened muscles showed opposite effects, with a depression in muscle activity of the calf muscles. The perturbations only slightly affected the spatio-temporal parameters, indicating that normal walking was retained. Thus, our findings showed that treadmill perturbations can evoke reflexes in the calf muscles and tibialis anterior. This comprehensive study could form the basis for clinical implementation of treadmill perturbations to functionally measure reflexes during treadmill-based clinical gait analysis.
- 15 December 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (12) , e0144815
Open AccessCan Treadmill Perturbations Evoke Stretch Reflexes in the Calf Muscles?
Disinhibition of reflexes is a problem amongst spastic patients, for it limits a smooth and efficient execution of motor functions during gait. Treadmill belt accelerations may potentially be used to measure reflexes during walking, i.e. by dorsal flexing the ankle and stretching the calf muscles, while decelerations show the modulation of reflexes during a reduction of sensory feedback. The aim of the current study was to examine if belt accelerations and decelerations of different intensities applied during the stance phase of treadmill walking can evoke reflexes in the gastrocnemius, soleus and tibialis anterior in healthy subjects. Muscle electromyography and joint kinematics were measured in 10 subjects. To determine whether stretch reflexes occurred, we assessed modelled musculo-tendon length and stretch velocity, the amount of muscle activity, as well as the incidence of bursts or depressions in muscle activity with their time delays, and co-contraction between agonist and antagonist muscle. Although the effect on the ankle angle was small with 2.8±1.0°, the perturbations caused clear changes in muscle length and stretch velocity relative to unperturbed walking. Stretched muscles showed an increasing incidence of bursts in muscle activity, which occurred after a reasonable electrophysiological time delay (163–191 ms). Their amplitude was related to the muscle stretch velocity and not related to co-contraction of the antagonist muscle. These effects increased with perturbation intensity. Shortened muscles showed opposite effects, with a depression in muscle activity of the calf muscles. The perturbations only slightly affected the spatio-temporal parameters, indicating that normal walking was retained. Thus, our findings showed that treadmill perturbations can evoke reflexes in the calf muscles and tibialis anterior. This comprehensive study could form the basis for clinical implementation of treadmill perturbations to functionally measure reflexes during treadmill-based clinical gait analysis.
- 1 October 2015
- Published by Elsevier in Gait & Posture
- Vol. 42 (4) , 498-504
Self-paced versus fixed speed walking and the effect of virtual reality in children with cerebral palsy
- 1 October 2015
- Published by Elsevier in Gait & Posture
- Vol. 42 (4) , 498-504
Self-paced versus fixed speed walking and the effect of virtual reality in children with cerebral palsy
- 1 June 2015
- Published by Elsevier in Gait & Posture
- Vol. 42 (1) , 7-15
The validity and reliability of modelled neural and tissue properties of the ankle muscles in children with cerebral palsy
- 1 June 2015
- Published by Elsevier in Gait & Posture
- Vol. 42 (1) , 7-15
The validity and reliability of modelled neural and tissue properties of the ankle muscles in children with cerebral palsy
- 25 April 2015
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (6) , 610-616
A comprehensive protocol to test instrumented treadmills
Instrumented treadmills are becoming more common in gait analysis. Due to their large and compliant structure, errors in force measurements are expected to be higher compared with conventional force plates. There is, however, no consistency in the literature on testing the performance of these treadmills. Therefore, we propose a standard protocol to assess and report error sources in instrumented treadmills. The first part of this protocol consists of assessment of the accuracy of forces and center of pressure (COP), including non-linearity, hysteresis and crosstalk. The second part consists of (novel) instrumented resonance testing and belt speed variability tests. The third part focuses on measurement variability over time, including drift, warming of the system and noise. The performance of two in-house instrumented treadmills with different dynamics was measured. Differences were found between the treadmills in COP accuracy (4.0 mm versus 6.5 mm), lowest eigen frequency (35 Hz versus 23 Hz) and noise level at 5 km/h (10 N versus 29 N). The loaded treadmills both showed a 3.3% belt speed variability at 5 km/h. Thus, the protocol was able to characterize strong and weak characteristics of the treadmills and allowed for a proper judgement on the validity of the instruments and their application in the domain of gait analysis. We propose to use this protocol when testing and reporting the performance of instrumented treadmills.
- 25 April 2015
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 37 (6) , 610-616
A comprehensive protocol to test instrumented treadmills
Instrumented treadmills are becoming more common in gait analysis. Due to their large and compliant structure, errors in force measurements are expected to be higher compared with conventional force plates. There is, however, no consistency in the literature on testing the performance of these treadmills. Therefore, we propose a standard protocol to assess and report error sources in instrumented treadmills. The first part of this protocol consists of assessment of the accuracy of forces and center of pressure (COP), including non-linearity, hysteresis and crosstalk. The second part consists of (novel) instrumented resonance testing and belt speed variability tests. The third part focuses on measurement variability over time, including drift, warming of the system and noise. The performance of two in-house instrumented treadmills with different dynamics was measured. Differences were found between the treadmills in COP accuracy (4.0 mm versus 6.5 mm), lowest eigen frequency (35 Hz versus 23 Hz) and noise level at 5 km/h (10 N versus 29 N). The loaded treadmills both showed a 3.3% belt speed variability at 5 km/h. Thus, the protocol was able to characterize strong and weak characteristics of the treadmills and allowed for a proper judgement on the validity of the instruments and their application in the domain of gait analysis. We propose to use this protocol when testing and reporting the performance of instrumented treadmills.
- 1 June 2014
- Published by Elsevier in Gait & Posture
- Vol. 39, S49-S50
The biomechanical effect of a virtual reality depends on treadmill mode
- 1 June 2014
- Published by Elsevier in Gait & Posture
- Vol. 39, S49-S50
The biomechanical effect of a virtual reality depends on treadmill mode
- 1 June 2014
- Published by Elsevier in Gait & Posture
- Vol. 39, S8-S9
How good is your instrumented treadmill?—A comprehensive protocol
- 1 June 2014
- Published by Elsevier in Gait & Posture
- Vol. 39, S8-S9
How good is your instrumented treadmill?—A comprehensive protocol