Clarissa Debiazi Zomer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Clarissa Debiazi Zomer has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ricardo Rüther
Fotovoltaica/UFSC, Universidade Federal de Santa Catarina, Florianópolis 88056-000, Brazil
2 shared publications André Nobre
Solar Energy Research Institute of Singapore (SERIS); National University of Singapore; 7 Engineering Drive 1, Block E3A, #06-01 117574 Singapore
1 shared publicationPablo Cassatella
Solar Energy Research Institute of Singapore (SERIS); National University of Singapore; 7 Engineering Drive 1, Block E3A, #06-01 117574 Singapore
1 shared publicationThomas Reindl
Solar Energy Research Institute of Singapore (SERIS); National University of Singapore; 7 Engineering Drive 1, Block E3A, #06-01 117574 Singapore
1 shared publication
Latest Publications
- Open Access
- 13 April 2014
- Published by Associação Brasileira de Energia Solar in Anais Congresso Brasileiro de Energia Solar - CBENS
CURVATURA E SOMBREAMENTO EM GERADORES FOTOVOLTAICOS
A curved photovoltaic system integrated to a residential roof in Singapore (1.35 ° N, 103.98 ° E) is presented in detail and its energy performance is discussed in the light of a shading analysis and its electrical configuration (subsystems division), in order to discuss whether the solutions adopted have contributed to a better performance of the PV array. Yield and performance ratio were compared between subsystems during a one year period (June 2012 to May 2013). Energy generation data were obtained by the data acquisition system from each inverter (subsystem) and the solar irradiance data were obtained from a weather station nearby the case study. The PV generator showed partial shadings for all subsystems at different intensities and times of the day and the year. Results showed good values of yield (1,296 kWh / kWp) and PR (84%) for Singapore when compared to reference values of systems for the same location, showing that even when a generator has no PV modules installed with the best combination of azimuthal deviation and tilt angle and is also partially shaded, it can still provide a good energy performance if the system has been well designed. Um sistema fotovoltaico curvo instalado sobre a cobertura de uma residência em Cingapura (1,35°N, 103,98°E) é apresentado em detalhe e o seu desempenho energético é discutido à luz de um estudo de sombreamento e de sua configuração elétrica (divisão de subsistemas), a fim de discutir se as soluções adotadas contribuíram para um melhor desempenho do gerador fotovoltaico. Os subsistemas da cobertura curva foram comparados em relação ao desempenho (yield) e à taxa de desempenho (performance ratio – PR) para o período de Junho de 2012 a Maio de 2013. Os dados de geração energética foram obtidos pelo sistema de aquisição de dados do gerador (SMA) para cada inversor (subsistema) e os dados de irradiação solar foram obtidos de uma estação meteorológica vizinha ao estudo de caso. O gerador fotovoltaico apresentou sombreamento parcial em todos os subsistemas, em diferentes intensidades e momentos do dia e do ano. Os resultados mostraram bons valores de yield (1.296 kWh/kWp) e PR (84%) para Cingapura quando comparados com valores de sistemas de referência para a mesma localidade, demonstrando que mesmo quando um gerador não possui os módulos fotovoltaicos instalados com a melhor combinação de desvio azimutal e ângulo de inclinação e é parcialmente sombreado, ele ainda pode apresentar um bom desempenho energético, se tiver sido bem projetado.
- 13 April 2014
- Published by Associação Brasileira de Energia Solar in Anais Congresso Brasileiro de Energia Solar - CBENS
Open AccessCURVATURA E SOMBREAMENTO EM GERADORES FOTOVOLTAICOS
A curved photovoltaic system integrated to a residential roof in Singapore (1.35 ° N, 103.98 ° E) is presented in detail and its energy performance is discussed in the light of a shading analysis and its electrical configuration (subsystems division), in order to discuss whether the solutions adopted have contributed to a better performance of the PV array. Yield and performance ratio were compared between subsystems during a one year period (June 2012 to May 2013). Energy generation data were obtained by the data acquisition system from each inverter (subsystem) and the solar irradiance data were obtained from a weather station nearby the case study. The PV generator showed partial shadings for all subsystems at different intensities and times of the day and the year. Results showed good values of yield (1,296 kWh / kWp) and PR (84%) for Singapore when compared to reference values of systems for the same location, showing that even when a generator has no PV modules installed with the best combination of azimuthal deviation and tilt angle and is also partially shaded, it can still provide a good energy performance if the system has been well designed. Um sistema fotovoltaico curvo instalado sobre a cobertura de uma residência em Cingapura (1,35°N, 103,98°E) é apresentado em detalhe e o seu desempenho energético é discutido à luz de um estudo de sombreamento e de sua configuração elétrica (divisão de subsistemas), a fim de discutir se as soluções adotadas contribuíram para um melhor desempenho do gerador fotovoltaico. Os subsistemas da cobertura curva foram comparados em relação ao desempenho (yield) e à taxa de desempenho (performance ratio – PR) para o período de Junho de 2012 a Maio de 2013. Os dados de geração energética foram obtidos pelo sistema de aquisição de dados do gerador (SMA) para cada inversor (subsistema) e os dados de irradiação solar foram obtidos de uma estação meteorológica vizinha ao estudo de caso. O gerador fotovoltaico apresentou sombreamento parcial em todos os subsistemas, em diferentes intensidades e momentos do dia e do ano. Os resultados mostraram bons valores de yield (1.296 kWh/kWp) e PR (84%) para Cingapura quando comparados com valores de sistemas de referência para a mesma localidade, demonstrando que mesmo quando um gerador não possui os módulos fotovoltaicos instalados com a melhor combinação de desvio azimutal e ângulo de inclinação e é parcialmente sombreado, ele ainda pode apresentar um bom desempenho energético, se tiver sido bem projetado.
- 31 October 2013
- Published by Wiley in Progress in Photovoltaics: Research and Applications
- Vol. 22 (7) , 744-756
The balance between aesthetics and performance in building-integrated photovoltaics in the tropics
- 31 October 2013
- Published by Wiley in Progress in Photovoltaics: Research and Applications
- Vol. 22 (7) , 744-756
The balance between aesthetics and performance in building-integrated photovoltaics in the tropics