Daniel R. Einstein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel R. Einstein has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ajit Prithivaraj Yoganathan
Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Ga
2 shared publications - Alan David Freed
Department of Mechanical Engineering, Texas A&M University, College Station, USA
2 shared publications - Andrew P. Kuprat
Pacific Northwest National Laboratory, Richland, WA, USA
2 shared publications - James P. Carson
Texas Advanced Computing Center, The University of Texas at Austin, Austin, TX, USA
2 shared publications - Milan Toma
Department of Osteopathic Manipulative Medicine, College of Osteopathic Medicine, New York Institute of Technology, Old Westbury, NY 11568, USA
2 shared publications - Richard A. Corley
Pacific Northwest National Laboratory, Richland, WA 99352, USA
2 shared publications
Latest Publications
- 19 April 2016
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 15 (6) , 1619-1630
High-resolution subject-specific mitral valve imaging and modeling: experimental and computational methods
The diversity of mitral valve (MV) geometries and multitude of surgical options for correction of MV diseases necessitates the use of computational modeling. Numerical simulations of the MV would allow surgeons and engineers to evaluate repairs, devices, procedures, and concepts before performing them and before moving on to more costly testing modalities. Constructing, tuning, and validating these models rely upon extensive in vitro characterization of valve structure, function, and response to change due to diseases. Micro-computed tomography (\(\mu \)CT) allows for unmatched spatial resolution for soft tissue imaging. However, it is still technically challenging to obtain an accurate geometry of the diastolic MV. We discuss here the development of a novel technique for treating MV specimens with glutaraldehyde fixative in order to minimize geometric distortions in preparation for \(\mu \)CT scanning. The technique provides a resulting MV geometry which is significantly more detailed in chordal structure, accurate in leaflet shape, and closer to its physiological diastolic geometry. In this paper, computational fluid–structure interaction (FSI) simulations are used to show the importance of more detailed subject-specific MV geometry with 3D chordal structure to simulate a proper closure validated against \(\mu \)CT images of the closed valve. Two computational models, before and after use of the aforementioned technique, are used to simulate closure of the MV.- 19 April 2016
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 15 (6) , 1619-1630
High-resolution subject-specific mitral valve imaging and modeling: experimental and computational methods
The diversity of mitral valve (MV) geometries and multitude of surgical options for correction of MV diseases necessitates the use of computational modeling. Numerical simulations of the MV would allow surgeons and engineers to evaluate repairs, devices, procedures, and concepts before performing them and before moving on to more costly testing modalities. Constructing, tuning, and validating these models rely upon extensive in vitro characterization of valve structure, function, and response to change due to diseases. Micro-computed tomography (\(\mu \)CT) allows for unmatched spatial resolution for soft tissue imaging. However, it is still technically challenging to obtain an accurate geometry of the diastolic MV. We discuss here the development of a novel technique for treating MV specimens with glutaraldehyde fixative in order to minimize geometric distortions in preparation for \(\mu \)CT scanning. The technique provides a resulting MV geometry which is significantly more detailed in chordal structure, accurate in leaflet shape, and closer to its physiological diastolic geometry. In this paper, computational fluid–structure interaction (FSI) simulations are used to show the importance of more detailed subject-specific MV geometry with 3D chordal structure to simulate a proper closure validated against \(\mu \)CT images of the closed valve. Two computational models, before and after use of the aforementioned technique, are used to simulate closure of the MV.- 17 July 2015
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 44 (4) , 942-953
Fluid–Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure
Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid–structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with \(\mu\)CT. Experimental data from the in vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed leaflet dynamics, and force vectors from the in vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements enable validating and adjusting material parameters to improve the accuracy of computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.- 17 July 2015
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 44 (4) , 942-953
Fluid–Structure Interaction Analysis of Papillary Muscle Forces Using a Comprehensive Mitral Valve Model with 3D Chordal Structure
Numerical models of native heart valves are being used to study valve biomechanics to aid design and development of repair procedures and replacement devices. These models have evolved from simple two-dimensional approximations to complex three-dimensional, fully coupled fluid–structure interaction (FSI) systems. Such simulations are useful for predicting the mechanical and hemodynamic loading on implanted valve devices. A current challenge for improving the accuracy of these predictions is choosing and implementing modeling boundary conditions. In order to address this challenge, we are utilizing an advanced in vitro system to validate FSI conditions for the mitral valve system. Explanted ovine mitral valves were mounted in an in vitro setup, and structural data for the mitral valve was acquired with \(\mu\)CT. Experimental data from the in vitro ovine mitral valve system were used to validate the computational model. As the valve closes, the hemodynamic data, high speed leaflet dynamics, and force vectors from the in vitro system were compared to the results of the FSI simulation computational model. The total force of 2.6 N per papillary muscle is matched by the computational model. In vitro and in vivo force measurements enable validating and adjusting material parameters to improve the accuracy of computational models. The simulations can then be used to answer questions that are otherwise not possible to investigate experimentally. This work is important to maximize the validity of computational models of not just the mitral valve, but any biomechanical aspect using computational simulation in designing medical devices.- 27 November 2013
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 13 (4) , 871-881
A membrane model from implicit elasticity theory: application to visceral pleura
A Fungean solid is derived for membranous materials as a body defined by isotropic response functions whose mathematical structure is that of a Hookean solid where the elastic constants are replaced by functions of state derived from an implicit, thermodynamic, internal energy function. The theory utilizes Biot’s (Lond Edinb Dublin Philos Mag J Sci 27:468–489, 1939) definitions for stress and strain that, in one-dimension, are the stress/strain measures adopted by Fung (Am J Physiol 28:1532–1544, 1967) when he postulated what is now known as Fung’s law. Our Fungean membrane model is parameterized against a biaxial data set acquired from a porcine pleural membrane subjected to three, sequential, proportional, planar extensions. These data support an isotropic/deviatoric split in the stress and strain-rate hypothesized by our theory. These data also demonstrate that the material response is highly nonlinear but, otherwise, mechanically isotropic. These data are described reasonably well by our otherwise simple, four-parameter, material model.
- 27 November 2013
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 13 (4) , 871-881
A membrane model from implicit elasticity theory: application to visceral pleura
A Fungean solid is derived for membranous materials as a body defined by isotropic response functions whose mathematical structure is that of a Hookean solid where the elastic constants are replaced by functions of state derived from an implicit, thermodynamic, internal energy function. The theory utilizes Biot’s (Lond Edinb Dublin Philos Mag J Sci 27:468–489, 1939) definitions for stress and strain that, in one-dimension, are the stress/strain measures adopted by Fung (Am J Physiol 28:1532–1544, 1967) when he postulated what is now known as Fung’s law. Our Fungean membrane model is parameterized against a biaxial data set acquired from a porcine pleural membrane subjected to three, sequential, proportional, planar extensions. These data support an isotropic/deviatoric split in the stress and strain-rate hypothesized by our theory. These data also demonstrate that the material response is highly nonlinear but, otherwise, mechanically isotropic. These data are described reasonably well by our otherwise simple, four-parameter, material model.
- 1 July 2013
- Published by Elsevier in Journal of Computational Physics
- Vol. 244, 148-167
A bidirectional coupling procedure applied to multiscale respiratory modeling
- 1 July 2013
- Published by Elsevier in Journal of Computational Physics
- Vol. 244, 148-167
A bidirectional coupling procedure applied to multiscale respiratory modeling
- 23 September 2012
- Published by Elsevier in International Journal of Engineering Science
- Vol. 62, 31-47
An implicit elastic theory for lung parenchyma
- 23 September 2012
- Published by Elsevier in International Journal of Engineering Science
- Vol. 62, 31-47
An implicit elastic theory for lung parenchyma
- Open Access
- 16 May 2012
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 29 (1) , 1-16
An efficient algorithm for mapping imaging data to 3D unstructured grids in computational biomechanics.
- 16 May 2012
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 29 (1) , 1-16
Open AccessAn efficient algorithm for mapping imaging data to 3D unstructured grids in computational biomechanics.