TMTetsuya Makiishi

Tetsuya Makiishi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tetsuya Makiishi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Sayako Maeda

    Department of Nephrology Otsu Red‐Cross Hospital Otsu Japan

    4 shared publications
  • Shinya Yamamoto

    Department of Internal Medicine, Division of Nephrology, Kitano Hospital, The Tazuke Kofukai Medical Research Institute, 2-4-20 Ohgimachi, Kita-Ku, Osaka, 530-8480, Japan.

    3 shared publications
  • Kunihiko Hirose

    Department of Cardiology, Otsu Red Cross Hospital, 1-1-35 Nagara, Shiga Otsu 520-8511, Japan

    2 shared publications
  • Sayako Maeda

    Division of Nephrology, Department of Internal Medicine, Otsu Red Cross Hospital, 1-1-35 Nagara, Otsu, Shiga, 520-8511, Japan

    2 shared publications
  • Shinya Yamamoto

    Division of Nephrology, Department of Internal Medicine, Kitano Hospital, The Tazuke Kofukai Medical Research Institute, 2-4-20 Ohgimachi, Kita-Ku, Osaka, 530-8480, Japan

    2 shared publications
  • Takashi Konishi

    Department of Cardiology, Otsu Red Cross Hospital, 1-1-35 Nagara, Shiga Otsu 520-8511, Japan

    2 shared publications

Latest Publications

  • Chronically Elevated Myeloperoxidase Antineutrophil Cytoplasmic Antibody Levels in an Asymptomatic 91-year-old Patient

    by Sayako Maeda1), Junko Yabuuchi1), Shinya Ono1), Tetsuya Makiishi1), Kunihiko Hirose2)

  • Open Access

    Potential Inaccuracies in Chloride Measurements in Patients with Severe Metabolic Acidosis

    by Tetsuya Makiishi, Naomasa Nishimura, Keiko Yoshioka, Shinya Yamamoto, Ryuichi Mitsuhashi, Sayako Maeda, Takashi Konishi, Kunihiko Hirose

    Background. To address the cause(s) of the significant differences in chloride (Cl-) concentrations between point-of-care blood gas analyzers and central laboratory analyzers.Methods. Cl-concentrations measured simultaneously by a blood gas analyzer (ABL800 FLEX) and a central laboratory analyzer (Hitachi7600) were collected in patients with severe acidemia (pH<7.20) (n=32) and were examined for correlations between differences in Cl-and factors associated with the acid-base status. Cl-concentrations were measured with both analyzers for samples with different concentrations of lactate, inorganic phosphate, or bicarbonate (HCO3   −).Results. The differences in Cl-concentrations were correlated withHCO3   −concentrations (r=0.72,P<0.0001) and anion gap (r=0.69,P<0.0001). Only the addition ofHCO3   −proportionately increased Cl-levels measured by a Hitachi7600, but it did not affect those measured by an ABL800FLEX.Conclusion. Cl-measurements with some analyzers may be influenced byHCO3   −concentrations, which could result in the observed discrepancies.


    • 1 January 2011
      • Vol. 53  (2) , 200-6

    [Case of suspected pseudo-elevation of serum creatinine immediately after intra-articular injection into a wrist joint of a pharmaceutical preparation of dexamethasone containing creatinine as a buffer].

    by Tetsuya Makiishi, Shinya Yamamoto, Sayako Maeda

    We report a case of suspected pseudo-elevation of serum creatinine in a patient with rheumatoid arthritis, whose blood sample was obtained from his right cubital vein immediately after the intra-articular injection of 0.67 mg of a pharmaceutical preparation of dexamethasone (Decadron) containing creatinine as a buffer into his right wrist joint to alleviate arthralgia. The 61-year-old male patient, who had been treated for rheumatoid arthritis, was referred to our outpatient clinic by his family doctor because of sudden elevation of his serum creatinine, which hitherto had been normal. Acute kidney injury (AKI) was suspected, but his medical history, physical examinations, and laboratory findings did not support the diagnosis of AKI. The preserved serum sample obtained when the elevation of his serum creatinine was reported was examined and revealed that the serum concentration of cystatin C was normal, but the serum concentration of creatinine measured with high-performance liquid chromatography method was elevated to a degree consistent with the serum creatinine concentration measured with enzymatic method. Accordingly, we predicted the possibility that creatinine contained in Decadron as a buffer was included in the measurement of his intrinsic serum creatinine. To test this hypothesis, the creatinine concentration of serum samples from another patient with known amounts of added Decadron were measured, and the additive effect of the extrinsic creatinine in the measurement of serum creatinine concentration was confirmed. These findings clearly suggest that we should consider the influence of extrinsic creatinine as an inactive ingredient in the measurement of serum creatinine.


    • 1 January 2011
      • Vol. 53  (2) , 212-8

    [Unstable hypertension due to renal artery compression by the developed diaphragm in a 17-year-old athlete: a case report].

    by Sayako Maeda, Shinya Yamamoto, Tetsuya Makiishi

    A 17-year-old high school boy was admitted to our hospital because of hypertension. Doppler ultrasound of the renal arteries and 3D-CT angiography showed a stenosis of the right renal artery, which was pushed against the aorta by the right crus of the diaphragm. He underwent aortography and selective renal arteriography. His right renal artery originated from the aorta at a higher level than the left renal artery, between the celiac artery and the superior mesenteric artery. Renal arteriography confirmed a 50% reduction in diameter (stenosis) of the proximal right renal artery entrapped by the right diaphragmatic crus. This pathology, unlike common renal artery stenosis, sometimes requires surgical decompression or an aortorenal bypass graft, because renal angioplasty with stenting is reported to be at risk of complication by a fracture of the stent. However, the patient rejected surgical decompression for fear of deterioration of his athletic ability. Therefore we decided to follow up his blood pressure and renal size by ultrasound every six months. Renovascular hypertension caused by diaphragmatic entrapment is a very rare disease. The diagnosis may be overlooked easily at angiography if optimal views are not obtained. It is important to display images of the renal arteries, the celiac artery and the superior mesenteric artery in both inspiration and expiration.

  • Pneumoperitoneum with Unperforated Acute Appendicitis in a Patient Undergoing Peritoneal Dialysis

    by Nobuhiro Hieda, Tetsuya Makiishi, Shinya Yamamoto, Sayako Maeda, Takashi Konishi, Kunihiko Hirose