Tetsuya Makiishi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tetsuya Makiishi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Sayako Maeda
Department of Nephrology Otsu Red‐Cross Hospital Otsu Japan
4 shared publications - Shinya Yamamoto
Department of Internal Medicine, Division of Nephrology, Kitano Hospital, The Tazuke Kofukai Medical Research Institute, 2-4-20 Ohgimachi, Kita-Ku, Osaka, 530-8480, Japan.
3 shared publications Kunihiko Hirose
Department of Cardiology, Otsu Red Cross Hospital, 1-1-35 Nagara, Shiga Otsu 520-8511, Japan
2 shared publicationsSayako Maeda
Division of Nephrology, Department of Internal Medicine, Otsu Red Cross Hospital, 1-1-35 Nagara, Otsu, Shiga, 520-8511, Japan
2 shared publicationsShinya Yamamoto
Division of Nephrology, Department of Internal Medicine, Kitano Hospital, The Tazuke Kofukai Medical Research Institute, 2-4-20 Ohgimachi, Kita-Ku, Osaka, 530-8480, Japan
2 shared publicationsTakashi Konishi
Department of Cardiology, Otsu Red Cross Hospital, 1-1-35 Nagara, Shiga Otsu 520-8511, Japan
2 shared publications
Latest Publications
- 1 January 2014
- Published by Wiley in General Medicine
- Vol. 15 (1) , 59-62
Chronically Elevated Myeloperoxidase Antineutrophil Cytoplasmic Antibody Levels in an Asymptomatic 91-year-old Patient
- 1 January 2014
- Published by Wiley in General Medicine
- Vol. 15 (1) , 59-62
Chronically Elevated Myeloperoxidase Antineutrophil Cytoplasmic Antibody Levels in an Asymptomatic 91-year-old Patient
- 30 January 2013
- Published by Springer Nature in CEN Case Reports
- Vol. 2 (2) , 134-138
AP-VAS 2012 case report: a case of lupus nephritis with predominant synchronous cellular crescent formation and myeloperoxidase-antineutrophil cytoplasmic antibody seropositivity
- 30 January 2013
- Published by Springer Nature in CEN Case Reports
- Vol. 2 (2) , 134-138
AP-VAS 2012 case report: a case of lupus nephritis with predominant synchronous cellular crescent formation and myeloperoxidase-antineutrophil cytoplasmic antibody seropositivity
- Open Access
- 12 June 2012
- Published by Hindawi Limited in International Journal of Nephrology
- Vol. 2012, 1-7
Potential Inaccuracies in Chloride Measurements in Patients with Severe Metabolic Acidosis
Background. To address the cause(s) of the significant differences in chloride (Cl-) concentrations between point-of-care blood gas analyzers and central laboratory analyzers.Methods. Cl-concentrations measured simultaneously by a blood gas analyzer (ABL800 FLEX) and a central laboratory analyzer (Hitachi7600) were collected in patients with severe acidemia () () and were examined for correlations between differences in Cl-and factors associated with the acid-base status. Cl-concentrations were measured with both analyzers for samples with different concentrations of lactate, inorganic phosphate, or bicarbonate ().Results. The differences in Cl-concentrations were correlated withconcentrations (,) and anion gap (,). Only the addition ofproportionately increased Cl-levels measured by a Hitachi7600, but it did not affect those measured by an ABL800FLEX.Conclusion. Cl-measurements with some analyzers may be influenced byconcentrations, which could result in the observed discrepancies.- 12 June 2012
- Published by Hindawi Limited in International Journal of Nephrology
- Vol. 2012, 1-7
Open AccessPotential Inaccuracies in Chloride Measurements in Patients with Severe Metabolic Acidosis
Background. To address the cause(s) of the significant differences in chloride (Cl-) concentrations between point-of-care blood gas analyzers and central laboratory analyzers.Methods. Cl-concentrations measured simultaneously by a blood gas analyzer (ABL800 FLEX) and a central laboratory analyzer (Hitachi7600) were collected in patients with severe acidemia () () and were examined for correlations between differences in Cl-and factors associated with the acid-base status. Cl-concentrations were measured with both analyzers for samples with different concentrations of lactate, inorganic phosphate, or bicarbonate ().Results. The differences in Cl-concentrations were correlated withconcentrations (,) and anion gap (,). Only the addition ofproportionately increased Cl-levels measured by a Hitachi7600, but it did not affect those measured by an ABL800FLEX.Conclusion. Cl-measurements with some analyzers may be influenced byconcentrations, which could result in the observed discrepancies. - 1 January 2011
- Vol. 53 (2) , 200-6
[Case of suspected pseudo-elevation of serum creatinine immediately after intra-articular injection into a wrist joint of a pharmaceutical preparation of dexamethasone containing creatinine as a buffer].
We report a case of suspected pseudo-elevation of serum creatinine in a patient with rheumatoid arthritis, whose blood sample was obtained from his right cubital vein immediately after the intra-articular injection of 0.67 mg of a pharmaceutical preparation of dexamethasone (Decadron) containing creatinine as a buffer into his right wrist joint to alleviate arthralgia. The 61-year-old male patient, who had been treated for rheumatoid arthritis, was referred to our outpatient clinic by his family doctor because of sudden elevation of his serum creatinine, which hitherto had been normal. Acute kidney injury (AKI) was suspected, but his medical history, physical examinations, and laboratory findings did not support the diagnosis of AKI. The preserved serum sample obtained when the elevation of his serum creatinine was reported was examined and revealed that the serum concentration of cystatin C was normal, but the serum concentration of creatinine measured with high-performance liquid chromatography method was elevated to a degree consistent with the serum creatinine concentration measured with enzymatic method. Accordingly, we predicted the possibility that creatinine contained in Decadron as a buffer was included in the measurement of his intrinsic serum creatinine. To test this hypothesis, the creatinine concentration of serum samples from another patient with known amounts of added Decadron were measured, and the additive effect of the extrinsic creatinine in the measurement of serum creatinine concentration was confirmed. These findings clearly suggest that we should consider the influence of extrinsic creatinine as an inactive ingredient in the measurement of serum creatinine.
- 1 January 2011
- Vol. 53 (2) , 200-6
[Case of suspected pseudo-elevation of serum creatinine immediately after intra-articular injection into a wrist joint of a pharmaceutical preparation of dexamethasone containing creatinine as a buffer].
We report a case of suspected pseudo-elevation of serum creatinine in a patient with rheumatoid arthritis, whose blood sample was obtained from his right cubital vein immediately after the intra-articular injection of 0.67 mg of a pharmaceutical preparation of dexamethasone (Decadron) containing creatinine as a buffer into his right wrist joint to alleviate arthralgia. The 61-year-old male patient, who had been treated for rheumatoid arthritis, was referred to our outpatient clinic by his family doctor because of sudden elevation of his serum creatinine, which hitherto had been normal. Acute kidney injury (AKI) was suspected, but his medical history, physical examinations, and laboratory findings did not support the diagnosis of AKI. The preserved serum sample obtained when the elevation of his serum creatinine was reported was examined and revealed that the serum concentration of cystatin C was normal, but the serum concentration of creatinine measured with high-performance liquid chromatography method was elevated to a degree consistent with the serum creatinine concentration measured with enzymatic method. Accordingly, we predicted the possibility that creatinine contained in Decadron as a buffer was included in the measurement of his intrinsic serum creatinine. To test this hypothesis, the creatinine concentration of serum samples from another patient with known amounts of added Decadron were measured, and the additive effect of the extrinsic creatinine in the measurement of serum creatinine concentration was confirmed. These findings clearly suggest that we should consider the influence of extrinsic creatinine as an inactive ingredient in the measurement of serum creatinine.
- 1 January 2011
- Vol. 53 (2) , 212-8
[Unstable hypertension due to renal artery compression by the developed diaphragm in a 17-year-old athlete: a case report].
A 17-year-old high school boy was admitted to our hospital because of hypertension. Doppler ultrasound of the renal arteries and 3D-CT angiography showed a stenosis of the right renal artery, which was pushed against the aorta by the right crus of the diaphragm. He underwent aortography and selective renal arteriography. His right renal artery originated from the aorta at a higher level than the left renal artery, between the celiac artery and the superior mesenteric artery. Renal arteriography confirmed a 50% reduction in diameter (stenosis) of the proximal right renal artery entrapped by the right diaphragmatic crus. This pathology, unlike common renal artery stenosis, sometimes requires surgical decompression or an aortorenal bypass graft, because renal angioplasty with stenting is reported to be at risk of complication by a fracture of the stent. However, the patient rejected surgical decompression for fear of deterioration of his athletic ability. Therefore we decided to follow up his blood pressure and renal size by ultrasound every six months. Renovascular hypertension caused by diaphragmatic entrapment is a very rare disease. The diagnosis may be overlooked easily at angiography if optimal views are not obtained. It is important to display images of the renal arteries, the celiac artery and the superior mesenteric artery in both inspiration and expiration.
- 1 January 2011
- Vol. 53 (2) , 212-8
[Unstable hypertension due to renal artery compression by the developed diaphragm in a 17-year-old athlete: a case report].
A 17-year-old high school boy was admitted to our hospital because of hypertension. Doppler ultrasound of the renal arteries and 3D-CT angiography showed a stenosis of the right renal artery, which was pushed against the aorta by the right crus of the diaphragm. He underwent aortography and selective renal arteriography. His right renal artery originated from the aorta at a higher level than the left renal artery, between the celiac artery and the superior mesenteric artery. Renal arteriography confirmed a 50% reduction in diameter (stenosis) of the proximal right renal artery entrapped by the right diaphragmatic crus. This pathology, unlike common renal artery stenosis, sometimes requires surgical decompression or an aortorenal bypass graft, because renal angioplasty with stenting is reported to be at risk of complication by a fracture of the stent. However, the patient rejected surgical decompression for fear of deterioration of his athletic ability. Therefore we decided to follow up his blood pressure and renal size by ultrasound every six months. Renovascular hypertension caused by diaphragmatic entrapment is a very rare disease. The diagnosis may be overlooked easily at angiography if optimal views are not obtained. It is important to display images of the renal arteries, the celiac artery and the superior mesenteric artery in both inspiration and expiration.
- 1 January 2011
- Published by Wiley in General Medicine
- Vol. 12 (2) , 89-90
Pneumoperitoneum with Unperforated Acute Appendicitis in a Patient Undergoing Peritoneal Dialysis
- 1 January 2011
- Published by Wiley in General Medicine
- Vol. 12 (2) , 89-90
Pneumoperitoneum with Unperforated Acute Appendicitis in a Patient Undergoing Peritoneal Dialysis