Laurence Bordenave
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Laurence Bordenave has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Didier Letourneur
Université Paris Cité, Université Sorbonne Paris Nord, INSERM 1148, LVTS, X Bichat Hospital
3 shared publications Alexandra Montembault
University Lyon, Université Lyon 1, Ingénierie des Matériaux Polymères (IMP), CNRS UMR 5223, 69622, Villeurbanne Cedex, France
2 shared publicationsAnnalisa Rivière
Service de Médecine Nucléaire
2 shared publications- Axelle Lascaux
Haematology Department, CHU Bordeaux, F-33000 Bordeaux, France
2 shared publications Charles Mesguich
Service de Médecine Nucléaire
2 shared publications- Charles Mesguich
CHU de Bordeaux, Service de Médecine nucléaire
2 shared publications
Latest Publications
- Open Access
Prospective Comparison of 18-FDG PET/CT and Whole-Body MRI with Diffusion-Weighted Imaging in the Evaluation of Treatment Response of Multiple Myeloma Patients Eligible for Autologous Stem Cell Transplant
To compare the prognostic values of 18-FDG PET/CT (FDG-PET) and Whole-Body MRI with Diffusion-Weighted Imaging (WB-DW-MRI) in the evaluation of treatment response of Multiple Myeloma (MM) patients eligible for ASCT. Thirty patients with newly diagnosed MM prospectively underwent FDG-PET and WB-DW-MRI at baseline, after induction chemotherapy and after ASCT. Response on WB-DW-MRI was evaluated with the MY-RADS criteria. FDG-PET was considered positive if residual uptake was superior to liver uptake. Imaging results were not used for treatment modification. The impact of imaging results on PFS was analyzed. After a median follow-up of 32 months, 10 patients relapsed. With WB-DW-MRI, post-induction examination was positive in 3/25 and post-ASCT examination was positive in 3/27 patients. However, neither study showed prognostic impact on PFS. FDG-PET was positive in 5/22 post-induction and 3/26 patients post-ASCT, respectively. Positivity of FDG-PET, post-induction or post-ASCT, was associated with a shorter PFS (post-induction: median PFS 19 months vs. not reached, log-rank p = 0.0089; post-ASCT: median PFS 18 months vs. not reached, log-rank p = 0.0005). Preliminary results from this small, single-center, prospective study show that, whether performed post-induction or post-ASCT, FDG-PET has a higher prognostic value than WB-DW-MRI for treatment response evaluation of newly diagnosed MM.
Open AccessProspective Comparison of 18-FDG PET/CT and Whole-Body MRI with Diffusion-Weighted Imaging in the Evaluation of Treatment Response of Multiple Myeloma Patients Eligible for Autologous Stem Cell Transplant
To compare the prognostic values of 18-FDG PET/CT (FDG-PET) and Whole-Body MRI with Diffusion-Weighted Imaging (WB-DW-MRI) in the evaluation of treatment response of Multiple Myeloma (MM) patients eligible for ASCT. Thirty patients with newly diagnosed MM prospectively underwent FDG-PET and WB-DW-MRI at baseline, after induction chemotherapy and after ASCT. Response on WB-DW-MRI was evaluated with the MY-RADS criteria. FDG-PET was considered positive if residual uptake was superior to liver uptake. Imaging results were not used for treatment modification. The impact of imaging results on PFS was analyzed. After a median follow-up of 32 months, 10 patients relapsed. With WB-DW-MRI, post-induction examination was positive in 3/25 and post-ASCT examination was positive in 3/27 patients. However, neither study showed prognostic impact on PFS. FDG-PET was positive in 5/22 post-induction and 3/26 patients post-ASCT, respectively. Positivity of FDG-PET, post-induction or post-ASCT, was associated with a shorter PFS (post-induction: median PFS 19 months vs. not reached, log-rank p = 0.0089; post-ASCT: median PFS 18 months vs. not reached, log-rank p = 0.0005). Preliminary results from this small, single-center, prospective study show that, whether performed post-induction or post-ASCT, FDG-PET has a higher prognostic value than WB-DW-MRI for treatment response evaluation of newly diagnosed MM.
- Open Access
Choline PET/CT in Multiple Myeloma
The field of multiple myeloma (MM) imaging has evolved. The International Myeloma Working Group recently recommended performing 18F-fluorodeoxyglucose glucose (18FDG) positron emission tomography/computed tomography (PET/CT) with the aim of staging MM patients at baseline and evaluating response to therapy. Novel oncological radiotracers such as 11C-Choline and 18F-Fluorocholine, have been studied in comparison with 18FDG, mostly in MM patients presenting with refractory disease or suspected relapse. Choline-based tracers may overcome some limitations of 18FDG, which include a lack of sensitivity in depicting skull lesions and the fact that 10% of MM patients are FDG-negative. The majority of MM lesions display a higher uptake of Choline than FDG. Also, in many situations, Choline may offer better lesion visualization, with a higher tumor to background ratio; however, various patterns of Choline and FDG uptake have been observed in MM and some limitations, notably as regards liver lesions, should be recognized. Overall, Choline may provide additional detection of up to 75% more lesions. This article aims to provide a comprehensive review of the potential role of Choline in multiple myeloma, as compared to FDG, encompassing Choline physiopathology as well as data from clinical studies.
Open AccessCholine PET/CT in Multiple Myeloma
The field of multiple myeloma (MM) imaging has evolved. The International Myeloma Working Group recently recommended performing 18F-fluorodeoxyglucose glucose (18FDG) positron emission tomography/computed tomography (PET/CT) with the aim of staging MM patients at baseline and evaluating response to therapy. Novel oncological radiotracers such as 11C-Choline and 18F-Fluorocholine, have been studied in comparison with 18FDG, mostly in MM patients presenting with refractory disease or suspected relapse. Choline-based tracers may overcome some limitations of 18FDG, which include a lack of sensitivity in depicting skull lesions and the fact that 10% of MM patients are FDG-negative. The majority of MM lesions display a higher uptake of Choline than FDG. Also, in many situations, Choline may offer better lesion visualization, with a higher tumor to background ratio; however, various patterns of Choline and FDG uptake have been observed in MM and some limitations, notably as regards liver lesions, should be recognized. Overall, Choline may provide additional detection of up to 75% more lesions. This article aims to provide a comprehensive review of the potential role of Choline in multiple myeloma, as compared to FDG, encompassing Choline physiopathology as well as data from clinical studies.
- 3 October 2017
- Published by IOP Publishing in Biomedical Materials
- Vol. 12 (6) , 065003
Chitosan-based hydrogels for developing a small-diameter vascular graft: in vitro and in vivo evaluation
Aims. Vascular grafts made of synthetic polymers perform poorly in small-diameter applications (cardiac and peripheral bypass). Chitosan is a biocompatible natural polymer that can provide a novel biological scaffold for tissue engineering development. The goal of this study was to demonstrate the biocompatibility of a novel chitosan preparation in vitro and in vivo , and to assess its potential as a scaffold for vascular applications. Methods and results. A series of experiments of increasing complexity, ranging from in vitro biocompatibility and hemocompatibility tests to in vivo studies in small and large animals (rats and sheep), was performed to provide a comprehensive analysis of chitosan hydrogels’ biological properties. In vitro studies established that: ( i ) chitosan supported human endothelial progenitor cells adhesion, proliferation and resistance to physiological shear stress; ( ii ) chitosan did not activate platelets, the complement system, or the intrinsic coagulation pathway. In vivo results showed: ( iii ) no resorption of chitosan and no chronic inflammation at 60 days in a rat heterotopic implantation model (magnetic resonance imaging and histology); ( iv ) no flow obstruction (Doppler ultrasound) and no thrombus formation (histology and scanning electron microscopy) at 2 h after a carotid arteriotomy repair with chitosan patches in sheep. Finally, two chitosan tubes were implanted as carotid interposition grafts for 3 days in sheep showing that chitosan was strong enough to be sutured, to withstand arterial pressure, and no flow obstruction was observed through this short period. Conclusion. Chitosan-based hydrogels displayed promising in vitro biocompatibility and hemocompatibility properties as well as in vivo short-term performance.
- 3 October 2017
- Published by IOP Publishing in Biomedical Materials
- Vol. 12 (6) , 065003
Chitosan-based hydrogels for developing a small-diameter vascular graft: in vitro and in vivo evaluation
Aims. Vascular grafts made of synthetic polymers perform poorly in small-diameter applications (cardiac and peripheral bypass). Chitosan is a biocompatible natural polymer that can provide a novel biological scaffold for tissue engineering development. The goal of this study was to demonstrate the biocompatibility of a novel chitosan preparation in vitro and in vivo , and to assess its potential as a scaffold for vascular applications. Methods and results. A series of experiments of increasing complexity, ranging from in vitro biocompatibility and hemocompatibility tests to in vivo studies in small and large animals (rats and sheep), was performed to provide a comprehensive analysis of chitosan hydrogels’ biological properties. In vitro studies established that: ( i ) chitosan supported human endothelial progenitor cells adhesion, proliferation and resistance to physiological shear stress; ( ii ) chitosan did not activate platelets, the complement system, or the intrinsic coagulation pathway. In vivo results showed: ( iii ) no resorption of chitosan and no chronic inflammation at 60 days in a rat heterotopic implantation model (magnetic resonance imaging and histology); ( iv ) no flow obstruction (Doppler ultrasound) and no thrombus formation (histology and scanning electron microscopy) at 2 h after a carotid arteriotomy repair with chitosan patches in sheep. Finally, two chitosan tubes were implanted as carotid interposition grafts for 3 days in sheep showing that chitosan was strong enough to be sutured, to withstand arterial pressure, and no flow obstruction was observed through this short period. Conclusion. Chitosan-based hydrogels displayed promising in vitro biocompatibility and hemocompatibility properties as well as in vivo short-term performance.
- 31 July 2017
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 10 (5-6) , 480-488
In Vitro Mechanical Property Evaluation of Chitosan-Based Hydrogels Intended for Vascular Graft Development
Vascular grafts made of synthetic polymers perform poorly in cardiac and peripheral bypass applications. In these applications, chitosan-based materials can be produced and shaped to provide a novel scaffold for vascular tissue engineering. The goal of this study was to evaluate in vitro the mechanical properties of a novel chitosan formulation to assess its potential for this scaffold. Two chitosan-based hydrogel tubes were produced by modulating chitosan concentration. Based on the standard ISO 7198:1998, the hydrogel tubes were characterized in vitro in terms of suture retention strength, tensile strength, compliance, and burst pressure. By increasing chitosan concentration, suture retention value increased to reach 1.1 N; average burst strength and elastic moduli also increased significantly. The compliance seemed to exhibit a low value for chitosan tubes of high concentration. By modulating chitosan concentration, we produced scaffolds with suitable mechanical properties to be implanted in vivo and withstand physiological blood pressures.
- 31 July 2017
- Published by Springer Nature in Journal of Cardiovascular Translational Research
- Vol. 10 (5-6) , 480-488
In Vitro Mechanical Property Evaluation of Chitosan-Based Hydrogels Intended for Vascular Graft Development
Vascular grafts made of synthetic polymers perform poorly in cardiac and peripheral bypass applications. In these applications, chitosan-based materials can be produced and shaped to provide a novel scaffold for vascular tissue engineering. The goal of this study was to evaluate in vitro the mechanical properties of a novel chitosan formulation to assess its potential for this scaffold. Two chitosan-based hydrogel tubes were produced by modulating chitosan concentration. Based on the standard ISO 7198:1998, the hydrogel tubes were characterized in vitro in terms of suture retention strength, tensile strength, compliance, and burst pressure. By increasing chitosan concentration, suture retention value increased to reach 1.1 N; average burst strength and elastic moduli also increased significantly. The compliance seemed to exhibit a low value for chitosan tubes of high concentration. By modulating chitosan concentration, we produced scaffolds with suitable mechanical properties to be implanted in vivo and withstand physiological blood pressures.
- Open Access
- 25 January 2017
- Published by EDP Sciences in médecine/sciences
- Vol. 33 (1) , 46-51
Ingénierie tissulaire
The prostheses have been around for thousands of years. Initially, it was substitute materials to replace members (leg, foot, hand) or for surgery (suture). The materials used have evolved, but they had never been created for medical applications. Recently, other strategies have emerged to construct or repair tissues. They are based on the use of biological components such as proteins or cells and provide a biological dimension to the term "biomaterial" and they often involve engineering. We illustrate the tissue engineering approaches using the examples of muscle and vessel regeneration strategies in the frame of restorative medicine.
- 25 January 2017
- Published by EDP Sciences in médecine/sciences
- Vol. 33 (1) , 46-51
Open AccessIngénierie tissulaire
The prostheses have been around for thousands of years. Initially, it was substitute materials to replace members (leg, foot, hand) or for surgery (suture). The materials used have evolved, but they had never been created for medical applications. Recently, other strategies have emerged to construct or repair tissues. They are based on the use of biological components such as proteins or cells and provide a biological dimension to the term "biomaterial" and they often involve engineering. We illustrate the tissue engineering approaches using the examples of muscle and vessel regeneration strategies in the frame of restorative medicine.
- Open Access
- 5 August 2016
- Published by Springer Nature in EJNMMI Physics
- Vol. 3 (1) , 1-12
Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during 18F-FDG preparation for PET/CT
The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses that are representative of the true doses received by the upper extremities of the operators. A prospective individual dosimetry study was performed in which the personal equivalent dose Hp (0.07) received during a specific 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) manual dose-dispensing procedure was measured in a paired design by two operational personal electronic dosimeters fitted on the palm side of the index finger, namely in the P1 and distal phalanx (P3) positions. The study participants were ten nuclear medicine technologists working in two nuclear medicine departments. The personal equivalent radiation doses received by the palm side of the proximal phalanx of the index finger [Hp (0.07)P1] and that received by the distal phalanx [Hp (0.07)P3] were compared. The median Hp (0.07)P3/Hp (0.07)P1 ratio per participant varied between 1.0 and 2.5 (based on 23 to 31 measurements per participant). The 271 paired measurements revealed a crude Hp (0.07)P3/Hp (0.07)P1 ratio of 1.67, significantly different from 1 (p = 0.0004, 95 % CI [1.35–2.07]). When adjusted on participant’s gender and mother vial activity, the ratio was similar (1.53, p = 0.003, 95 % CI [1.22–1.92]). The study demonstrated a significant disparity that may exist between the radiation doses measured in the P1 and P3 positions of operators during 18F-FDG manipulation. These findings emphasize the importance of performing workplace dosimetry studies adapted to each radiopharmaceutical and manipulation thereof, aiming to guarantee optimal workers’ dosimetry monitoring schemes. Hospital Nursing and Paramedical Research Program (PHRIP, 2011–2013) from the French Ministry of Health (DGOS), http://social-sante.gouv.fr/IMG/pdf/Resultats_PHRIP_2011.pdf
- 5 August 2016
- Published by Springer Nature in EJNMMI Physics
- Vol. 3 (1) , 1-12
Open AccessEffect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during 18F-FDG preparation for PET/CT
The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses that are representative of the true doses received by the upper extremities of the operators. A prospective individual dosimetry study was performed in which the personal equivalent dose Hp (0.07) received during a specific 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) manual dose-dispensing procedure was measured in a paired design by two operational personal electronic dosimeters fitted on the palm side of the index finger, namely in the P1 and distal phalanx (P3) positions. The study participants were ten nuclear medicine technologists working in two nuclear medicine departments. The personal equivalent radiation doses received by the palm side of the proximal phalanx of the index finger [Hp (0.07)P1] and that received by the distal phalanx [Hp (0.07)P3] were compared. The median Hp (0.07)P3/Hp (0.07)P1 ratio per participant varied between 1.0 and 2.5 (based on 23 to 31 measurements per participant). The 271 paired measurements revealed a crude Hp (0.07)P3/Hp (0.07)P1 ratio of 1.67, significantly different from 1 (p = 0.0004, 95 % CI [1.35–2.07]). When adjusted on participant’s gender and mother vial activity, the ratio was similar (1.53, p = 0.003, 95 % CI [1.22–1.92]). The study demonstrated a significant disparity that may exist between the radiation doses measured in the P1 and P3 positions of operators during 18F-FDG manipulation. These findings emphasize the importance of performing workplace dosimetry studies adapted to each radiopharmaceutical and manipulation thereof, aiming to guarantee optimal workers’ dosimetry monitoring schemes. Hospital Nursing and Paramedical Research Program (PHRIP, 2011–2013) from the French Ministry of Health (DGOS), http://social-sante.gouv.fr/IMG/pdf/Resultats_PHRIP_2011.pdf
- 1 August 2015
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 22 (4) , 799-1
Erratum to: High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
- 1 August 2015
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 22 (4) , 799-1
Erratum to: High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
- 19 March 2015
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 22 (4) , 787-798
High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
- 19 March 2015
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 22 (4) , 787-798
High performances of 18F-fluorodeoxyglucose PET-CT in cardiac implantable device infections: A study of 40 patients
- 1 August 2014
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 21 (4) , 845-848
The usefulness of FDG PET/CT imaging in suspicion of LVAD infection
- 1 August 2014
- Published by Elsevier in Journal of Nuclear Cardiology
- Vol. 21 (4) , 845-848
The usefulness of FDG PET/CT imaging in suspicion of LVAD infection
- 8 November 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 102 (10) , 3666-3676
Physicochemical modulation of chitosan‐based hydrogels induces different biological responses: Interest for tissue engineering
Polysaccharide‐based hydrogels are remarkable materials for the development of tissue engineering strategies as they meet several critical requirements for such applications and they may partly mimic the extracellular matrix. Chitosan is widely envisioned as hydrogel in biomedical fields for its bioresorbability, biocompatibility, and fungistatic and bacteriostatic properties. In this study, we report that the modulation of the polymer concentration, the degree of acetylation, the gelation processes [or neutralization routes (NR)] in the preparation of different chitosan‐based hydrogels lead to substantially and significantly different biological responses. We show that it is possible to tune the physicochemical characteristics, mechanical properties, and biological responses of such matrices. Physical hydrogels prepared from highly acetylated chitosan were softer, degraded quickly in vivo, and were not suitable for in vitro culture of human mesenchymal stem and progenitor derived endothelial cells. In contrast, for a same chitosan concentration and obtained by the same processing route, a low degree of acetylation chitosan hydrogel provided a more elastic material, better cell adhesion on its surface and tissue regeneration, and restored tissue neo‐vascularization as well. This work offers promising and innovative perspectives for the design of hydrogel materials with tunable properties for tissue engineering and regenerative medicine. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 3666–3676, 2014.
- 8 November 2013
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 102 (10) , 3666-3676
Physicochemical modulation of chitosan‐based hydrogels induces different biological responses: Interest for tissue engineering
Polysaccharide‐based hydrogels are remarkable materials for the development of tissue engineering strategies as they meet several critical requirements for such applications and they may partly mimic the extracellular matrix. Chitosan is widely envisioned as hydrogel in biomedical fields for its bioresorbability, biocompatibility, and fungistatic and bacteriostatic properties. In this study, we report that the modulation of the polymer concentration, the degree of acetylation, the gelation processes [or neutralization routes (NR)] in the preparation of different chitosan‐based hydrogels lead to substantially and significantly different biological responses. We show that it is possible to tune the physicochemical characteristics, mechanical properties, and biological responses of such matrices. Physical hydrogels prepared from highly acetylated chitosan were softer, degraded quickly in vivo, and were not suitable for in vitro culture of human mesenchymal stem and progenitor derived endothelial cells. In contrast, for a same chitosan concentration and obtained by the same processing route, a low degree of acetylation chitosan hydrogel provided a more elastic material, better cell adhesion on its surface and tissue regeneration, and restored tissue neo‐vascularization as well. This work offers promising and innovative perspectives for the design of hydrogel materials with tunable properties for tissue engineering and regenerative medicine. © 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 102A: 3666–3676, 2014.