Abdul Haleem Panhwar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abdul Haleem Panhwar has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Tasneem Gul Kazi
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan
27 shared publications - Hassan Imran Afridi
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan
23 shared publications - Kapil Dev Brahman
National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan
19 shared publications - Sadaf Sadia Arain
National Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
18 shared publications - Naeem Ullah
University of Sindh
13 shared publications - Salma Aslam Arain
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan
12 shared publications
Latest Publications
- 3 May 2016
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 6 (3) , 272-285
Evaluation of Toxic Metals and Their Exposure via Drinking Water of Different Origin Using Multivariate Technique: Health Risk Assessment
In the current study, we monitored the potentially toxic level of lead (Pb), aluminum (Al), cadmium (Cd) and other physicochemical parameters in different types of drinking water samples of district Jamshoro. Moreover, the objective of this research was the possible risk assessment of hazardous metals level in different types of drinking water used in the local population. The concentrations of toxic metals in water samples of different origin were analyzed using atomic absorption spectrometry. It was observed that the levels of Al, Cd and Pb in lake and ground water elevated as compared to the WHO recommended permissible level. Concentrations of toxic metals in lake and ground water were considerably elevated (p<0.001) as compared to domestic treated water. Based on concentrations of toxic metals; chronic daily intake (CDI) and hazard quotient (HQ) were calculated as factors for health risk assessment. CDI and HQ for lake and ground water revealed that water is unsafe for human activities while the domestic treated water has lower CDI and HQ values. Furthermore, it was also exposed through results obtained with cluster analysis (CA) and principal component analysis (PCA) that geogenic as well as anthropogenic actions is the major contamination cause in understudy area.
- 3 May 2016
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 6 (3) , 272-285
Evaluation of Toxic Metals and Their Exposure via Drinking Water of Different Origin Using Multivariate Technique: Health Risk Assessment
In the current study, we monitored the potentially toxic level of lead (Pb), aluminum (Al), cadmium (Cd) and other physicochemical parameters in different types of drinking water samples of district Jamshoro. Moreover, the objective of this research was the possible risk assessment of hazardous metals level in different types of drinking water used in the local population. The concentrations of toxic metals in water samples of different origin were analyzed using atomic absorption spectrometry. It was observed that the levels of Al, Cd and Pb in lake and ground water elevated as compared to the WHO recommended permissible level. Concentrations of toxic metals in lake and ground water were considerably elevated (p<0.001) as compared to domestic treated water. Based on concentrations of toxic metals; chronic daily intake (CDI) and hazard quotient (HQ) were calculated as factors for health risk assessment. CDI and HQ for lake and ground water revealed that water is unsafe for human activities while the domestic treated water has lower CDI and HQ values. Furthermore, it was also exposed through results obtained with cluster analysis (CA) and principal component analysis (PCA) that geogenic as well as anthropogenic actions is the major contamination cause in understudy area.
- 29 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (15) , 2436-2445
Preconcentration of Cadmium in Water and Hair by Supramolecular Solvent-Based Dispersive Liquid–Liquid Microextraction
Supramolecular solvent based liquid–liquid microextraction is reported as a green preconcentration technique for the determination of cadmium using 1-decanol dispersed in tetrahydrofuran (the supramolecular solvent). Cadmium was complexed with ammonium-pyrrolidine dithiocarbamate and the supramolecular solvent was added to produce nanosized micelles. The metal complex was extracted into the supramolecular solvent. The factors influencing the extraction efficiency of cadmium and its subsequent determination were optimized, including the pH, the volume of sample, the mass of ligand, and the type and volume of supramolecular solvent. Using the optimum conditions, the limit of detection for cadmium was 0.23 µg/L. Preconcentration factors of 25 and 100 were obtained for biological materials and water, respectively. The methodology was validated using a certified reference material. The results show that the method is rapid, simple, sensitive, and efficient for the determination of cadmium in water and hair.
- 29 February 2016
- Published by Taylor & Francis in Analytical Letters
- Vol. 49 (15) , 2436-2445
Preconcentration of Cadmium in Water and Hair by Supramolecular Solvent-Based Dispersive Liquid–Liquid Microextraction
Supramolecular solvent based liquid–liquid microextraction is reported as a green preconcentration technique for the determination of cadmium using 1-decanol dispersed in tetrahydrofuran (the supramolecular solvent). Cadmium was complexed with ammonium-pyrrolidine dithiocarbamate and the supramolecular solvent was added to produce nanosized micelles. The metal complex was extracted into the supramolecular solvent. The factors influencing the extraction efficiency of cadmium and its subsequent determination were optimized, including the pH, the volume of sample, the mass of ligand, and the type and volume of supramolecular solvent. Using the optimum conditions, the limit of detection for cadmium was 0.23 µg/L. Preconcentration factors of 25 and 100 were obtained for biological materials and water, respectively. The methodology was validated using a certified reference material. The results show that the method is rapid, simple, sensitive, and efficient for the determination of cadmium in water and hair.
- 1 February 2016
- Published by Elsevier in Science of The Total Environment
- Vol. 544, 653-660
Exposure of children to arsenic in drinking water in the Tharparkar region of Sindh, Pakistan
- 1 February 2016
- Published by Elsevier in Science of The Total Environment
- Vol. 544, 653-660
Exposure of children to arsenic in drinking water in the Tharparkar region of Sindh, Pakistan
- 1 January 2016
- Published by Elsevier in Microchemical Journal
- Vol. 124, 290-295
Arsenic speciation in artificial saliva extract of smokeless tobacco products by extraction methodologies coupled with electrothermal atomic absorption spectrometry
- 1 January 2016
- Published by Elsevier in Microchemical Journal
- Vol. 124, 290-295
Arsenic speciation in artificial saliva extract of smokeless tobacco products by extraction methodologies coupled with electrothermal atomic absorption spectrometry
- 17 December 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (4) , 904-911
Switchable dispersive liquid–liquid microextraction for lead enrichment: a green alternative to classical extraction techniques
A new, innovative and green switchable dispersive liquid–liquid microextraction (SDLLME) method has been introduced as a preconcentration tool for the removal of the toxic metal lead (Pb) in fresh and waste water samples prior to determination with flame atomic absorption spectrometry. We developed a switchable polarity solvent (SPS) system, based on 1,8-diazabicyclo[5.4.0]undec-7-ene and decanol, which was reversibly switched on and off from heterogeneous biphasic nonpolar hydrophobic phase to homogeneous monophasic polar hydrophilic phase in an aqueous medium through exposure to an anti-solvent trigger (CO2) for a specific interval of time (1–10 min). Then, an SPS of polar microemulsions was switched on from a polar phase through bubbling CO2 followed by switching off to a nonpolar phase by heating in the range of 40–70 °C in the presence of N2 gas. The switching phenomenon of SPS from low polarity to high polarity was confirmed by FTIR spectrophotometry and conductivity measurements. SDLLME was successfully applied as an extracting method for the preconcentration of a hydrophobic chelate of Pb with 1-(2-pyridylazo)-2-naphthol (Pb-PAN) from a real water system. Then hydrophobic-enriched Pb-PAN-SPS was treated with a 1.5 mol L−1 HNO3 and CO2 purge for different time intervals, to switch back to its miscible polar hydrophilic monophasic state. The recovery of SPS was carried out by heating at 55 °C and purging with N2 gas. The SPS was easily recycled up to 12 times with >2% loss of efficiency of the developed method. Under the optimized experimental conditions, the limit of detection and the enhancement factor were determined to be 0.25 μg L−1 and 50, respectively.
- 17 December 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (4) , 904-911
Switchable dispersive liquid–liquid microextraction for lead enrichment: a green alternative to classical extraction techniques
A new, innovative and green switchable dispersive liquid–liquid microextraction (SDLLME) method has been introduced as a preconcentration tool for the removal of the toxic metal lead (Pb) in fresh and waste water samples prior to determination with flame atomic absorption spectrometry. We developed a switchable polarity solvent (SPS) system, based on 1,8-diazabicyclo[5.4.0]undec-7-ene and decanol, which was reversibly switched on and off from heterogeneous biphasic nonpolar hydrophobic phase to homogeneous monophasic polar hydrophilic phase in an aqueous medium through exposure to an anti-solvent trigger (CO2) for a specific interval of time (1–10 min). Then, an SPS of polar microemulsions was switched on from a polar phase through bubbling CO2 followed by switching off to a nonpolar phase by heating in the range of 40–70 °C in the presence of N2 gas. The switching phenomenon of SPS from low polarity to high polarity was confirmed by FTIR spectrophotometry and conductivity measurements. SDLLME was successfully applied as an extracting method for the preconcentration of a hydrophobic chelate of Pb with 1-(2-pyridylazo)-2-naphthol (Pb-PAN) from a real water system. Then hydrophobic-enriched Pb-PAN-SPS was treated with a 1.5 mol L−1 HNO3 and CO2 purge for different time intervals, to switch back to its miscible polar hydrophilic monophasic state. The recovery of SPS was carried out by heating at 55 °C and purging with N2 gas. The SPS was easily recycled up to 12 times with >2% loss of efficiency of the developed method. Under the optimized experimental conditions, the limit of detection and the enhancement factor were determined to be 0.25 μg L−1 and 50, respectively.
- 25 November 2015
- Published by Springer Nature in Biological Trace Element Research
- Vol. 172 (1) , 61-71
Toxic Risk Assessment of Arsenic in Males Through Drinking Water in Tharparkar Region of Sindh, Pakistan
Humans are exposed to arsenic (As) through air, drinking water, and food. The arsenic (As) hazardous quotient was calculated on the basis of its concentration in drinking water of different origin and scalp hair of male subjects (n = 313), residents of different exposed and non-exposed areas of Sindh, Pakistan. The total As was determined in water and scalp hair samples, while As species were determined in water samples by advance extraction methodologies. The total As concentrations in drinking water of less-exposed (LE) and high-exposed (HE) areas was found to be 2.63 to 4.46 and 52 to 235, fold higher than the permissible limit, respectively, than recommended by World Health Organization (2004) for drinking water. While the levels of As in drinking water of non-exposed (NE) areas was within the permissible limit. The resulted data indicated that the dominant species was As+5 in groundwater samples. The levels of As in scalp hair samples of male subjects of two age groups (18–30 and 31–50 years), belonging to NE, LE, and HE areas, ranged from 0.26 to 0.69, 0.58 to 1.34, and 15.6 to 60.9 μg/g, respectively. A significant correlation between As levels in drinking water and scalp hair was observed in HE area (r = 0.86–0.90, p < 0.001) as compared to those subjects belonging to LE area. A toxicity risk assessment was calculated as hazard quotient (HQ), which indicates that the study subjects of HE area have significantly higher values of HQ than LE. The population of As exposed areas is at high risk of non-carcinogenic and carcinogenesis effects.
- 25 November 2015
- Published by Springer Nature in Biological Trace Element Research
- Vol. 172 (1) , 61-71
Toxic Risk Assessment of Arsenic in Males Through Drinking Water in Tharparkar Region of Sindh, Pakistan
Humans are exposed to arsenic (As) through air, drinking water, and food. The arsenic (As) hazardous quotient was calculated on the basis of its concentration in drinking water of different origin and scalp hair of male subjects (n = 313), residents of different exposed and non-exposed areas of Sindh, Pakistan. The total As was determined in water and scalp hair samples, while As species were determined in water samples by advance extraction methodologies. The total As concentrations in drinking water of less-exposed (LE) and high-exposed (HE) areas was found to be 2.63 to 4.46 and 52 to 235, fold higher than the permissible limit, respectively, than recommended by World Health Organization (2004) for drinking water. While the levels of As in drinking water of non-exposed (NE) areas was within the permissible limit. The resulted data indicated that the dominant species was As+5 in groundwater samples. The levels of As in scalp hair samples of male subjects of two age groups (18–30 and 31–50 years), belonging to NE, LE, and HE areas, ranged from 0.26 to 0.69, 0.58 to 1.34, and 15.6 to 60.9 μg/g, respectively. A significant correlation between As levels in drinking water and scalp hair was observed in HE area (r = 0.86–0.90, p < 0.001) as compared to those subjects belonging to LE area. A toxicity risk assessment was calculated as hazard quotient (HQ), which indicates that the study subjects of HE area have significantly higher values of HQ than LE. The population of As exposed areas is at high risk of non-carcinogenic and carcinogenesis effects.
- 7 October 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (21) , 9211-9217
Determination of trace levels of iron in serum samples of hepatitis B and C patients using dispersive liquid–liquid microextraction
An environmentally friendly ionic liquid-based dispersive liquid–liquid microextraction (IL-DLLμE) method was developed for the preconcentration of trace levels of iron (Fe) in serum samples of hepatitis B and C patients, prior to its determination by flame atomic absorption spectrometry. The procedure was based on complexation of iron with a chelating reagent, 8-hydroxyquinoline (oxine), whereas an ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6], and ethanol were chosen as extracting and dispersive solvents, respectively. The factors affecting the efficiency of IL-DLLμE, such as the amount of IL, pH, centrifugation time and ligand concentration, were investigated in detail. The resulting data indicated that the coexisting cations and anions ions had no apparent influence on determination of Fe at trace levels. Under optimal experimental conditions, the enhancement factor and the limit of detection were 59.1 and 1.29 μg L−1, respectively. The relative standard deviation for five replicate determinations of Fe at 50 μg L−1 was calculated to be <5.0%. The developed method was validated by determining Fe in a certified reference material of serum. The proposed method can be successfully used for the enrichment of Fe in acid digested serum samples of female hepatitis B and C patients.
- 7 October 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (21) , 9211-9217
Determination of trace levels of iron in serum samples of hepatitis B and C patients using dispersive liquid–liquid microextraction
An environmentally friendly ionic liquid-based dispersive liquid–liquid microextraction (IL-DLLμE) method was developed for the preconcentration of trace levels of iron (Fe) in serum samples of hepatitis B and C patients, prior to its determination by flame atomic absorption spectrometry. The procedure was based on complexation of iron with a chelating reagent, 8-hydroxyquinoline (oxine), whereas an ionic liquid, 1-butyl-3-methylimidazolium hexafluorophosphate [C4MIM][PF6], and ethanol were chosen as extracting and dispersive solvents, respectively. The factors affecting the efficiency of IL-DLLμE, such as the amount of IL, pH, centrifugation time and ligand concentration, were investigated in detail. The resulting data indicated that the coexisting cations and anions ions had no apparent influence on determination of Fe at trace levels. Under optimal experimental conditions, the enhancement factor and the limit of detection were 59.1 and 1.29 μg L−1, respectively. The relative standard deviation for five replicate determinations of Fe at 50 μg L−1 was calculated to be <5.0%. The developed method was validated by determining Fe in a certified reference material of serum. The proposed method can be successfully used for the enrichment of Fe in acid digested serum samples of female hepatitis B and C patients.
- 9 August 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 22 (23) , 19251-19263
Evaluation of the fate of arsenic-contaminated groundwater at different aquifers of Thar coalfield Pakistan
In present study, the ground water at different aquifers was evaluated for physicochemical parameters, iron, total arsenic, total inorganic arsenic and arsenic species (arsenite and arsenate). The samples of groundwater were collected at different depths, first aquifer (AQ1) 50–60 m, second aquifer (AQ2) 100–120 m, and third aquifer (AQ3) 200–250 m of Thar coalfield, Pakistan. Total inorganic arsenic was determined by solid phase extraction using titanium dioxide as an adsorbent. The arsenite was determined by cloud point extraction using ammonium pyrrolidinedithiocarbamate as a chelating reagent, and resulted complex was extracted by Triton X-114. The resulted data of groundwater were reported in terms of basic statistical parameters, principal component, and cluster analysis. The resulted data indicated that physicochemical parameters of groundwater of different aquifers were exceeded the World Health Organization provisional guideline for drinking water except pH and SO4 2−. The positive correlation was observed between arsenic species and physicochemical parameters of groundwater except F− and K+, which might be caused by geochemical minerals. Results of cluster analysis indicated that groundwater samples of AQ1 was highly contaminated with arsenic species as compared to AQ2 and AQ3 (p > 0.05). Graphical Abstract ᅟ ᅟ
- 9 August 2015
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 22 (23) , 19251-19263
Evaluation of the fate of arsenic-contaminated groundwater at different aquifers of Thar coalfield Pakistan
In present study, the ground water at different aquifers was evaluated for physicochemical parameters, iron, total arsenic, total inorganic arsenic and arsenic species (arsenite and arsenate). The samples of groundwater were collected at different depths, first aquifer (AQ1) 50–60 m, second aquifer (AQ2) 100–120 m, and third aquifer (AQ3) 200–250 m of Thar coalfield, Pakistan. Total inorganic arsenic was determined by solid phase extraction using titanium dioxide as an adsorbent. The arsenite was determined by cloud point extraction using ammonium pyrrolidinedithiocarbamate as a chelating reagent, and resulted complex was extracted by Triton X-114. The resulted data of groundwater were reported in terms of basic statistical parameters, principal component, and cluster analysis. The resulted data indicated that physicochemical parameters of groundwater of different aquifers were exceeded the World Health Organization provisional guideline for drinking water except pH and SO4 2−. The positive correlation was observed between arsenic species and physicochemical parameters of groundwater except F− and K+, which might be caused by geochemical minerals. Results of cluster analysis indicated that groundwater samples of AQ1 was highly contaminated with arsenic species as compared to AQ2 and AQ3 (p > 0.05). Graphical Abstract ᅟ ᅟ