Atsushi Shimizu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Atsushi Shimizu has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Alan Kawarai Lefor
Department of Surgery, Jichi Medical University, Shimotsuke, Tochigi, Japan
7 shared publications - Naohiro Sata
Department of Surgery, Division of Gastroenterological, General and Transplant Surgery, Jichi Medical University, Shimotsuke, Japan
4 shared publications - Atsushi Miki
Department of Surgery, Division of Gastroenterological, General and Transplant Surgery, Jichi Medical University, Shimotsuke, Japan
3 shared publications - Hideki Sasanuma
Division of Gastroenterological, General and Transplant Surgery, Department of Surgery, Jichi Medical University, Japan
3 shared publications Yasunaru Sakuma
Department of Surgery Jichi Medical University Shimotsuke‐shi Tochigi‐ken Japan
3 shared publications- Yoshikazu Yasuda
Division of Gastroenterological, General and Transplant Surgery, Department of Surgery, Jichi Medical University, Shimotsuke, Japan
3 shared publications
Latest Publications
- 2 July 2025
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 51 (10) , 110297
Hepatic clearance of remnant liver for assessing lobar difference of liver function in patients with perihilar cholangiocarcinoma: single center experience
- 2 July 2025
- Published by Elsevier in European Journal of Surgical Oncology
- Vol. 51 (10) , 110297
Hepatic clearance of remnant liver for assessing lobar difference of liver function in patients with perihilar cholangiocarcinoma: single center experience
- Open Access
- 20 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-8
Remnant liver function is associated with long-term survival in patients with hepatocellular carcinoma undergoing hepatectomy
It is important to assess the prognosis and intervene before and after surgery in patients with hepatocellular carcinoma. This study aims to elucidate the association of outcomes and residual liver function after hepatectomy. A total of 176 patients who underwent the initial resection for hepatocellular carcinoma between January 2011 and March 2021 at Jichi Medical University were included. Hepatic clearance of the remnant liver was measured using 99mTc-galactosyl serum albumin scintigraphy. The log-rank test was used to analyze survival using the Kaplan–Meier method. Hazard ratios (HR) and 95% confidence intervals (CI) for overall survival were calculated using Cox’s proportional hazard model. In multivariate analysis, microvascular invasion, intraoperative blood loss, and hepatic clearance of the remnant liver were independently associated with overall survival. Hepatic clearance of the remnant liver was independently associated with recurrence free survival. This is the first report to show that lower residual liver function is associated with shorter survival in patients with hepatocellular carcinoma undergoing hepatectomy. Preoperative determination of remnant liver function may allow assessment of prognosis in patients planned to undergo resection of hepatocellular carcinoma. Preservation of liver functional reserve may be crucial for improved long-term outcomes after hepatectomy.
- 20 September 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-8
Open AccessRemnant liver function is associated with long-term survival in patients with hepatocellular carcinoma undergoing hepatectomy
It is important to assess the prognosis and intervene before and after surgery in patients with hepatocellular carcinoma. This study aims to elucidate the association of outcomes and residual liver function after hepatectomy. A total of 176 patients who underwent the initial resection for hepatocellular carcinoma between January 2011 and March 2021 at Jichi Medical University were included. Hepatic clearance of the remnant liver was measured using 99mTc-galactosyl serum albumin scintigraphy. The log-rank test was used to analyze survival using the Kaplan–Meier method. Hazard ratios (HR) and 95% confidence intervals (CI) for overall survival were calculated using Cox’s proportional hazard model. In multivariate analysis, microvascular invasion, intraoperative blood loss, and hepatic clearance of the remnant liver were independently associated with overall survival. Hepatic clearance of the remnant liver was independently associated with recurrence free survival. This is the first report to show that lower residual liver function is associated with shorter survival in patients with hepatocellular carcinoma undergoing hepatectomy. Preoperative determination of remnant liver function may allow assessment of prognosis in patients planned to undergo resection of hepatocellular carcinoma. Preservation of liver functional reserve may be crucial for improved long-term outcomes after hepatectomy.
- Open Access
- 17 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4145
Development and Validation of a Virtual Reality Simulator for Robot-Assisted Minimally Invasive Liver Surgery Training
The value of kinematic data for skill assessment is being investigated. This is the first virtual reality simulator developed for liver surgery. This simulator was coded in C++ using PhysX and FleX with a novel cutting algorithm and used a patient data-derived model and two instruments functioning as ultrasonic shears. The simulator was evaluated by nine expert surgeons and nine surgical novices. Each participant performed a simulated metastasectomy after training. Kinematic data were collected for the instrument position. Each participant completed a survey. The expert participants had a mean age of 47 years and 9/9 were certified in surgery. Novices had a mean age of 30 years and 0/9 were certified surgeons. The mean path length (novice 0.76 ± 0.20 m vs. expert 0.46 ± 0.16 m, p = 0.008), movements (138 ± 45 vs. 84 ± 32, p = 0.043) and time (174 ± 44 s vs. 102 ± 42 s, p = 0.004) were significantly different for the two participant groups. There were no significant differences in activating the instrument (107 ± 25 vs. 109 ± 53). Participants considered the simulator realistic (6.5/7) (face validity), appropriate for education (5/7) (content validity) with an effective interface (6/7), consistent motion (5/7) and realistic soft tissue behavior (5/7). This study showed that the simulator differentiates between experts and novices. Simulation may be an effective way to obtain kinematic data.
- 17 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4145
Open AccessDevelopment and Validation of a Virtual Reality Simulator for Robot-Assisted Minimally Invasive Liver Surgery Training
The value of kinematic data for skill assessment is being investigated. This is the first virtual reality simulator developed for liver surgery. This simulator was coded in C++ using PhysX and FleX with a novel cutting algorithm and used a patient data-derived model and two instruments functioning as ultrasonic shears. The simulator was evaluated by nine expert surgeons and nine surgical novices. Each participant performed a simulated metastasectomy after training. Kinematic data were collected for the instrument position. Each participant completed a survey. The expert participants had a mean age of 47 years and 9/9 were certified in surgery. Novices had a mean age of 30 years and 0/9 were certified surgeons. The mean path length (novice 0.76 ± 0.20 m vs. expert 0.46 ± 0.16 m, p = 0.008), movements (138 ± 45 vs. 84 ± 32, p = 0.043) and time (174 ± 44 s vs. 102 ± 42 s, p = 0.004) were significantly different for the two participant groups. There were no significant differences in activating the instrument (107 ± 25 vs. 109 ± 53). Participants considered the simulator realistic (6.5/7) (face validity), appropriate for education (5/7) (content validity) with an effective interface (6/7), consistent motion (5/7) and realistic soft tissue behavior (5/7). This study showed that the simulator differentiates between experts and novices. Simulation may be an effective way to obtain kinematic data.
- Open Access
- 7 June 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (12) , 3254
Laparoscopic and Robot-Assisted Hepatic Surgery: An Historical Review
Hepatic surgery is a rapidly expanding component of abdominal surgery and is performed for a wide range of indications. The introduction of laparoscopic cholecystectomy in 1987 was a major change in abdominal surgery. Laparoscopic surgery was widely and rapidly adopted throughout the world for cholecystectomy initially and then applied to a variety of other procedures. Laparoscopic surgery became regularly applied to hepatic surgery, including segmental and major resections as well as organ donation. Many operations progressed from open surgery to laparoscopy to robot-assisted surgery, including colon resection, pancreatectomy, splenectomy thyroidectomy, adrenalectomy, prostatectomy, gastrectomy, and others. It is difficult to prove a data-based benefit using robot-assisted surgery, although laparoscopic and robot-assisted surgery of the liver are not inferior regarding major outcomes. When laparoscopic surgery initially became popular, many had concerns about its use to treat malignancies. Robot-assisted surgery is being used to treat a variety of benign and malignant conditions, and studies have shown no deterioration in outcomes. Robot-assisted surgery for the treatment of malignancies has become accepted and is now being used at more centers. The outcomes after robot-assisted surgery depend on its use at specialized centers, the surgeon’s personal experience backed up by extensive training and maintenance of international registries. Robot-assisted hepatic surgery has been shown to be associated with slightly less intraoperative blood loss and shorter hospital lengths of stay compared to open surgery. Oncologic outcomes have been maintained, and some studies show higher rates of R0 resections. Patients who need surgery for liver lesions should identify a surgeon they trust and should not be concerned with the specific operative approach used. The growth of robot-assisted surgery of the liver has occurred in a stepwise approach which is very different from the frenzy that was seen with the introduction of laparoscopic cholecystectomy. This approach allowed the identification of areas for improvement, many of which are at the nexus of engineering and medicine. Further improvements in robot-assisted surgery depend on the combined efforts of engineers and surgeons.
- 7 June 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (12) , 3254
Open AccessLaparoscopic and Robot-Assisted Hepatic Surgery: An Historical Review
Hepatic surgery is a rapidly expanding component of abdominal surgery and is performed for a wide range of indications. The introduction of laparoscopic cholecystectomy in 1987 was a major change in abdominal surgery. Laparoscopic surgery was widely and rapidly adopted throughout the world for cholecystectomy initially and then applied to a variety of other procedures. Laparoscopic surgery became regularly applied to hepatic surgery, including segmental and major resections as well as organ donation. Many operations progressed from open surgery to laparoscopy to robot-assisted surgery, including colon resection, pancreatectomy, splenectomy thyroidectomy, adrenalectomy, prostatectomy, gastrectomy, and others. It is difficult to prove a data-based benefit using robot-assisted surgery, although laparoscopic and robot-assisted surgery of the liver are not inferior regarding major outcomes. When laparoscopic surgery initially became popular, many had concerns about its use to treat malignancies. Robot-assisted surgery is being used to treat a variety of benign and malignant conditions, and studies have shown no deterioration in outcomes. Robot-assisted surgery for the treatment of malignancies has become accepted and is now being used at more centers. The outcomes after robot-assisted surgery depend on its use at specialized centers, the surgeon’s personal experience backed up by extensive training and maintenance of international registries. Robot-assisted hepatic surgery has been shown to be associated with slightly less intraoperative blood loss and shorter hospital lengths of stay compared to open surgery. Oncologic outcomes have been maintained, and some studies show higher rates of R0 resections. Patients who need surgery for liver lesions should identify a surgeon they trust and should not be concerned with the specific operative approach used. The growth of robot-assisted surgery of the liver has occurred in a stepwise approach which is very different from the frenzy that was seen with the introduction of laparoscopic cholecystectomy. This approach allowed the identification of areas for improvement, many of which are at the nexus of engineering and medicine. Further improvements in robot-assisted surgery depend on the combined efforts of engineers and surgeons.
- 27 October 2021
- Published by SAGE Publications in American Journal of Hospice and Palliative Medicine®
- Vol. 39 (8) , 907-912
Physician Attire Influences Patient and Family Perceptions of Care in the Palliative Care Unit in Japan
Background: Physician attire influences perceptions of care. This study was conducted to evaluate the impact of physician attire on perceptions of care by patients and families in a Japanese palliative care unit. Methods: From November 2018 to February 2020, patients and family members admitted to the Palliative Care Unit at Jichi Medical University Hospital were recruited and completed a survey consisting of 4 demographic questions and 15 questions regarding perceptions of care. A 7-point Likert scale (1 = strongly agree, 4 = neutral, 7 = strongly disagree) was used to judge attire (name tag, long sleeve white coat, short sleeve white coat, scrubs, scrub color, jeans, sneakers) addressing patient and overall impact on perception of care. Results: Of 203 patients admitted, 79 were enrolled. Surveys were received from 23 patients and 52 family members. Patients and families want physicians to wear name tags (median, interquartile range) (2, 1-2) and white coats (3, 2-4). Patients want to be addressed by surnames (2, 1.5-4). Patients and family members have neutral opinions about short sleeve white coats (4, 4-4) and scrubs (4, 4-4). Jeans were not liked (4, 4-6) while sneakers are acceptable (3, 2-4). The impact of attire on perceptions of care is significantly (p = .04) greater for patients (3, 2-4) than family members (4, 3-4). Conclusion: Patients and family members prefer their physicians to wear name tags and white coats and address patients by surnames. Physician attire has a significantly greater impact on perceptions of care for patients than family members in a palliative care unit.
- 27 October 2021
- Published by SAGE Publications in American Journal of Hospice and Palliative Medicine®
- Vol. 39 (8) , 907-912
Physician Attire Influences Patient and Family Perceptions of Care in the Palliative Care Unit in Japan
Background: Physician attire influences perceptions of care. This study was conducted to evaluate the impact of physician attire on perceptions of care by patients and families in a Japanese palliative care unit. Methods: From November 2018 to February 2020, patients and family members admitted to the Palliative Care Unit at Jichi Medical University Hospital were recruited and completed a survey consisting of 4 demographic questions and 15 questions regarding perceptions of care. A 7-point Likert scale (1 = strongly agree, 4 = neutral, 7 = strongly disagree) was used to judge attire (name tag, long sleeve white coat, short sleeve white coat, scrubs, scrub color, jeans, sneakers) addressing patient and overall impact on perception of care. Results: Of 203 patients admitted, 79 were enrolled. Surveys were received from 23 patients and 52 family members. Patients and families want physicians to wear name tags (median, interquartile range) (2, 1-2) and white coats (3, 2-4). Patients want to be addressed by surnames (2, 1.5-4). Patients and family members have neutral opinions about short sleeve white coats (4, 4-4) and scrubs (4, 4-4). Jeans were not liked (4, 4-6) while sneakers are acceptable (3, 2-4). The impact of attire on perceptions of care is significantly (p = .04) greater for patients (3, 2-4) than family members (4, 3-4). Conclusion: Patients and family members prefer their physicians to wear name tags and white coats and address patients by surnames. Physician attire has a significantly greater impact on perceptions of care for patients than family members in a palliative care unit.
- 18 July 2020
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 42 (12) , 1485-1488
Couinaud Type A communicating accessory bile duct: report of a case
Background Communicating accessory bile ducts are defined as ducts that communicate between major biliary channels but do not drain individual segments of the liver. The Couinaud Type A communicating accessory bile duct is a rare anomaly where an aberrant duct connects the right main hepatic duct to the common hepatic duct without segmental drainage. There are very few reports of this anomaly in the literature to date. Case presentation A 75-year-old male who died of ischemic heart disease donated his body for cadaveric dissection, which included careful attention to the anatomy of the hepatic hilum. During dissection, it was found that the right hepatic duct was duplicated and an accessory duct drained directly into the common hepatic duct. Although rare and difficult to visualize even with modern preoperative imaging techniques, sound knowledge of this rare anatomic variation is imperative to avoid inadvertent intraoperative biliary injuries which can lead to severe morbidity. Conclusions An aberrant bile duct from the right hepatic duct to the common hepatic duct (Couinaud Type A) is an uncommon accessory bile duct that one must be aware of when performing complex hepatobiliary procedures such as right liver resection for living-related donation. Detailed preoperative imaging and careful dissection with anticipation of anomalous anatomy are of the utmost importance for the safe conduct of hepatic surgery.
- 18 July 2020
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 42 (12) , 1485-1488
Couinaud Type A communicating accessory bile duct: report of a case
Background Communicating accessory bile ducts are defined as ducts that communicate between major biliary channels but do not drain individual segments of the liver. The Couinaud Type A communicating accessory bile duct is a rare anomaly where an aberrant duct connects the right main hepatic duct to the common hepatic duct without segmental drainage. There are very few reports of this anomaly in the literature to date. Case presentation A 75-year-old male who died of ischemic heart disease donated his body for cadaveric dissection, which included careful attention to the anatomy of the hepatic hilum. During dissection, it was found that the right hepatic duct was duplicated and an accessory duct drained directly into the common hepatic duct. Although rare and difficult to visualize even with modern preoperative imaging techniques, sound knowledge of this rare anatomic variation is imperative to avoid inadvertent intraoperative biliary injuries which can lead to severe morbidity. Conclusions An aberrant bile duct from the right hepatic duct to the common hepatic duct (Couinaud Type A) is an uncommon accessory bile duct that one must be aware of when performing complex hepatobiliary procedures such as right liver resection for living-related donation. Detailed preoperative imaging and careful dissection with anticipation of anomalous anatomy are of the utmost importance for the safe conduct of hepatic surgery.
- 19 March 2018
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 33 (6) , 763-769
Reappraisal of the lateral rectal ligament: an anatomical study of total mesorectal excision with autonomic nerve preservation
The term “lateral rectal ligament” in surgery for rectal cancer has caused confusion regarding its true existence and contents. In previous studies, investigators claimed the existence of the ligament and described its topographical features as neurovascular structures and their surrounding connective tissues located at the anterolateral aspect of the distal rectum or the posterolateral aspect of the middle rectum. The purpose of this study is to evaluate the structure of the so-called “lateral rectal ligament” in cadaver dissections.
- 19 March 2018
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 33 (6) , 763-769
Reappraisal of the lateral rectal ligament: an anatomical study of total mesorectal excision with autonomic nerve preservation
The term “lateral rectal ligament” in surgery for rectal cancer has caused confusion regarding its true existence and contents. In previous studies, investigators claimed the existence of the ligament and described its topographical features as neurovascular structures and their surrounding connective tissues located at the anterolateral aspect of the distal rectum or the posterolateral aspect of the middle rectum. The purpose of this study is to evaluate the structure of the so-called “lateral rectal ligament” in cadaver dissections.
- 18 February 2015
- Published by Wiley in Pediatric Transplantation
- Vol. 19 (3) , 279-286
The impact of rituximab in ABO‐incompatible pediatric living donor liver transplantation: The experience of a single center
Previous studies have demonstrated the safety of ABO‐incompatible pediatric LDLT using preoperative plasmapheresis and rituximab; however, no reports have described the timing and dosage of rituximab administration for pediatric LDLT. This study aimed to describe a safe and effective dosage and timing of rituximab for patients undergoing pediatric ABO‐incompatible LDLT based on the experience of our single center. A total of 192 LDLTs in 187 patients were examined. These cases included 29 ABO‐incompatible LDLTs in 28 patients. Rituximab was used beginning in January 2004 in recipients older than two yr of age (first period: 375 mg/m2 in two cases; second period: 50 mg/m2 in two cases; and 200 mg/m2 in eight cases). Two patients who received 375 mg/m2 rituximab died of Pneumocystis carinii pneumonia and hemophagocytic syndrome. One patient who received 50 mg/m2 rituximab required retransplantation as a consequence of antibody‐mediated complications. All eight patients administered 200 mg/m2 survived, and the mean CD20+ lymphocyte count was 0.1% at the time of LDLT. In the preoperative management of patients undergoing pediatric ABO‐incompatible LDLT, the administration of 200 mg/m2 rituximab three wk prior to LDLT was safe and effective.
- 18 February 2015
- Published by Wiley in Pediatric Transplantation
- Vol. 19 (3) , 279-286
The impact of rituximab in ABO‐incompatible pediatric living donor liver transplantation: The experience of a single center
Previous studies have demonstrated the safety of ABO‐incompatible pediatric LDLT using preoperative plasmapheresis and rituximab; however, no reports have described the timing and dosage of rituximab administration for pediatric LDLT. This study aimed to describe a safe and effective dosage and timing of rituximab for patients undergoing pediatric ABO‐incompatible LDLT based on the experience of our single center. A total of 192 LDLTs in 187 patients were examined. These cases included 29 ABO‐incompatible LDLTs in 28 patients. Rituximab was used beginning in January 2004 in recipients older than two yr of age (first period: 375 mg/m2 in two cases; second period: 50 mg/m2 in two cases; and 200 mg/m2 in eight cases). Two patients who received 375 mg/m2 rituximab died of Pneumocystis carinii pneumonia and hemophagocytic syndrome. One patient who received 50 mg/m2 rituximab required retransplantation as a consequence of antibody‐mediated complications. All eight patients administered 200 mg/m2 survived, and the mean CD20+ lymphocyte count was 0.1% at the time of LDLT. In the preoperative management of patients undergoing pediatric ABO‐incompatible LDLT, the administration of 200 mg/m2 rituximab three wk prior to LDLT was safe and effective.
- Open Access
- 1 January 2014
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 5 (5) , 219-221
Embolization of a fractured central venous catheter placed using the internal jugular approach
INTRODUCTION: Fracture and embolization of central venous catheters placed via the subclavian approach is well recognized, but fractured catheters placed via the internal jugular vein are extremely rare. PRESENTATION OF CASE: A 65-year-old man presented with a catheter embolus after placement of a central venous port using the internal jugular approach undertaken to administer adjuvant chemotherapy for colon cancer with lung metastases. Goose neck and conformational loop snares were successfully used to percutaneously retrieve the severed catheter, which had migrated to the right ventricle. DISCUSSION: Catheter fracture may occur even after placement via the internal jugular approach and may be underestimated because it is often asymptomatic. Interventional radiology techniques using goose-neck and conformational loop snares may be useful to retract an intravascular foreign body. CONCLUSION: Imaging studies such as a chest X-ray are mandatory to check that the catheter tip is in the appropriate position during the entire follow-up period even if it was placed through the internal jugular vein.
- 1 January 2014
- Published by Wolters Kluwer Health in International Journal of Surgery Case Reports
- Vol. 5 (5) , 219-221
Open AccessEmbolization of a fractured central venous catheter placed using the internal jugular approach
INTRODUCTION: Fracture and embolization of central venous catheters placed via the subclavian approach is well recognized, but fractured catheters placed via the internal jugular vein are extremely rare. PRESENTATION OF CASE: A 65-year-old man presented with a catheter embolus after placement of a central venous port using the internal jugular approach undertaken to administer adjuvant chemotherapy for colon cancer with lung metastases. Goose neck and conformational loop snares were successfully used to percutaneously retrieve the severed catheter, which had migrated to the right ventricle. DISCUSSION: Catheter fracture may occur even after placement via the internal jugular approach and may be underestimated because it is often asymptomatic. Interventional radiology techniques using goose-neck and conformational loop snares may be useful to retract an intravascular foreign body. CONCLUSION: Imaging studies such as a chest X-ray are mandatory to check that the catheter tip is in the appropriate position during the entire follow-up period even if it was placed through the internal jugular vein.