JCJose de la Cruz

Jose de la Cruz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jose de la Cruz has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Surgical applications of expanded polytetrafluoroethylene in ophthalmology: A review

    by Raul E. Ruiz-Lozano, Amanda K. Bicket, Ian Pitha, Nambi Nallasamy, Maria S. Cortina, Jose de la Cruz, Anitha Venugopal

  • Novel Management of Ocular Surface Inflammation in Patients With Ocular Graft-Versus-Host Disease in the Setting of Cataract Surgery

    by Daniela Roca, Sandeep Jain, Christine B.S. Mun, Monazzah Akbar Sarwar, Ellen O.D. Shorter, Gustavo Ortiz-Morales, Imane Tarib, Jose De La Cruz

    Purpose: To report the outcomes of cataract surgery in patients with ocular graft-versus-host disease (oGVHD) using a novel preoperative immunomodulatory regimen in a collaborative subspecialty care setting. Methods: Retrospective case series of patients with oGVHD who underwent cataract surgery using a novel preoperative immunomodulatory regimen in a collaborative care setting. A preoperative regimen consisting of pooled human immune globulin 1%, autologous serum 50%, and methylprednisolone 1% eye drops was prescribed. Outcome measures included visual acuity (VA), ocular surface disease index (OSDI) score, lissamine green staining, and complications with a minimum of 2 years of follow-up. Results: Thirty-five eyes from 20 patients with oGVHD were studied. The mean age was 59 years (range 30–70 years). A healthy comparison group included 35 eyes from 24 patients with a mean age of 63 years (range 44–74 years). At the 2-year follow-up, the mean corneal staining score was 2.3/15, the mean OSDI score was 37.5, and the mean VA was 20/30 (logarithm of the minimal angle of resolution 0.17). The global complication rate was 2.8% at the last follow-up with no difference versus a healthy comparison group. Conclusions: A collaborative care model improving ocular surface health before cataract surgery with dry eye and cataract subspecialists can optimize outcomes in patients with oGVHD.


  • Keratoprosthesis

    by Jennifer Park, Faris I. Karas, Jose de la Cruz, M. Soledad Cortina

  • Keratoprosthesis

    by Jennifer Park, Faris I. Karas, Jose de la Cruz, M. Soledad Cortina

  • Direct and Indirect Flap Measurements in Femtosecond Laser–Assisted In Situ Keratomileusis

    by Joao Crispim, Norma Allemann, Joelle A. Hallak, Dimitri T. Azar, Jose De La Cruz

    Purpose: To compare direct and indirect LASIK flap thickness measurements using ultrasound and Scheimpflug technology. Methods: Eighty-two eyes treated with laser-assisted in situ keratomileusis refractive surgery using a femtosecond laser (IntraLase FS150) were prospectively included in the study. Flap thickness was set to 115 μm. Corneal flap thickness was measured using the direct method—ie, ultrasound pachymetry immediately after flap construction in the presence of cavitation bubbles—and indirect methods, with subtraction of intraoperative post-lift corneal thickness measured using ultrasound pachymetry (intrastroma) from preoperative central corneal thickness using ultrasound (Indirect-US) or Scheimpflug thinnest pachymetry (Indirect-Scheimpflug). Results: Mean flap thickness was overestimated using the indirect methods, Indirect-US and Indirect-Scheimpflug (122.6 ± 24.5 μm and 128.1 ± 26.1 μm, respectively; P < 0.0060 and P < 0.0001, respectively). There were no significant correlations between the direct and indirect methods. Indirect-Scheimpflug was significantly higher (P = 0.0122) than Indirect-US. The closest average flap thickness compared with the set parameter of 115 μm was that of the direct method (115.6 ± 8.6 μm; 95% confidence interval: −1.3 to 2.5; P = 0.5163). The direct method provided the lowest SD of all groups (SD: 8.64). Conclusions: The direct method of flap thickness measurement was the most comparable to the set parameter compared with the indirect subtraction methods. Additional studies are needed to determine which method allows for the most accurate measurement of flap thickness.

  • Femtosecond laser-assisted cataract surgery (FLACS) in resident training

    by Jennifer Park, Carmen Somavilla Bueno, Jose de la Cruz

    This article reviews the history of the femtosecond laser in ophthalmology and its subsequent introduction into the field of cataract surgery. It discusses the innovations that this technology has brought to the field. The article also describes the current system of teaching cataract surgery to ophthalmology residents in the United States and then examines how femtosecond laser-assisted cataract surgery (FLACS) can be a beneficial part of residency education.

  • Safety of Femtosecond Laser-Assisted Cataract Surgery Performed by Surgeons in Training

    by Joshua H. Hou, Adam L. Prickett, Maria S. Cortina, Sandeep Jain, Jose de la Cruz

    Letters to the Editor Joshua H. Hou, MD; Adam L. Prickett, MD; Maria S. Cortina, MD; Sandeep Jain, MD; Jose de la Cruz, MD Dr. de la Cruz is a consultant for Alcon Laboratories, Inc., Fort Worth, TX. The remaining authors have no financial or proprietary interest in the materials presented herein. Femtosecond laser-assisted cataract surgery has grown in popularity among ophthalmologists as a novel technique with the potential to reduce phacoemulsification energy requirements.1,2 However, early adoption of femtosecond laser-assisted cataract surgery by experienced cataract surgeons has been associated with a significant learning curve.3 Roberts et al. reported higher complication rates in the first 200 cases of femtosecond laser-assisted cataract surgery compared to 1,300 subsequent cases at a single high-volume practice.3 Given the challenges faced by experienced surgeons adopting femtosecond laser-assisted cataract surgery, it is unclear whether it can be safely performed by residents in training. We describe our experience with incorporating femtosecond laser-assisted cataract surgery in resident and fellow surgical training. After receiving Institutional Review Board approval, we performed a retrospective case–control study of resident and fellow outcomes with femtosecond laser-assisted versus manual cataract surgery. All cataract surgeries performed at our institution from June 2012 to September 2013 by third-year residents and fellows with no prior femtosecond laser-assisted cataract surgery experience were identified. Cases performed without a femtosecond laser were included as manual cases. Cases in which wound construction, anterior capsulotomy, and lens fragmentation were performed using the LenSx femtosecond laser platform (Alcon Laboratories, Inc., Fort Worth, TX) were included as femtosecond laser-assisted cases. Cases were excluded if there was no documentation of intraoperative phacoemulsification parameters or if the case was not staffed by a corneal specialist experienced in femtosecond laser-assisted cataract surgery. Complications and phacoemulsification parameters, including phacoemulsification times, cumulative dissipated energy, aspiration time, and irrigation fluid use were compared between femtosecond laser-assisted and manual cases using a t test. In total, 62 femtosecond laser-assisted and 128 manual cataract surgery cases met inclusion criteria. There was no statistical difference in mean age (P = .12) or cataract grade (P = .31) between the two groups. Successful docking was achieved in 96.8% of eyes scheduled for femtosecond laser-assisted cataract surgery. Attending assistance was required in 46.8% of those eyes. Mean irrigation fluid use and cumulative dissipated energy were 22.5% and 38.2% higher, respectively, for manual cases (P ≤ .001). Total ultrasound, phacoemulsification, torsional, and aspiration times were all statistically higher in manual cases (P < .01) (Figure 1). In a sub-analysis excluding fellow cases, cumulative dissipated energy, fluid use, and phacoemulsification and torsional times remained statistically higher in manual cases despite the smaller sample size (P ≤ .03). In total, four posterior capsular tears and one burn wound occurred in the manual group. No posterior capsular tears or burn wounds occurred in the femtosecond laser-assisted group. Figure 1. Comparison of phacoemulsification parameters between manual and femtosecond laser-assisted cataract surgery (FACS) performed by residents and fellows. Error bars show 95% confidence intervals. Asterisks indicate statistically significant differences by t test. This pilot study suggests that femtosecond laser-assisted cataract surgery can be safely incorporated in resident and fellow surgical training. Given the high success rate (96.8%), docking was not a problem for residents performing femtosecond laser-assisted cataract surgery. Overall, the complication rate for manual cases (7.0%) was consistent with published rates for residents.4–6 However, surprisingly, fewer complications were noted in the femtosecond laser-assisted group. The presence of supervision during femtosecond laser-assisted cataract surgery may have helped to lower rates. Given the lack of complications and favorable phacoemulsification use profile with femtosecond laser-assisted cataract surgery, this study is reassuring evidence that it can be performed safely by surgeons in training. This study was limited by its retrospective nature and small sample size. Larger, randomized, controlled studies are needed to further evaluate the safety and efficacy of femtosecond laser-assisted cataract surgery performed by surgeons in training. Joshua H. Hou, MD Adam L. Prickett, MD Maria S. Cortina, MD Sandeep Jain, MD Jose de la Cruz, MD Chicago, Illinois Figure 1. Comparison of phacoemulsification parameters between manual and femtosecond laser-assisted cataract surgery (FACS) performed by residents and fellows. Error bars show 95% confidence intervals. Asterisks indicate statistically significant differences by t test. 10.3928/1081597X-20141218-07


  • Management of Traumatic LASIK Flap Edge Invagination

    by Samuel H. Lee, Dimitri T. Azar, Jose de la Cruz

  • History of the Artificial Cornea

    by Samuel H. Lee, M. Soledad Cortina, Jose de la Cruz