JPJörg Peter

Jörg Peter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jörg Peter has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Applying Time-Dependent Data for Fluorescence Tomography

    by Ralf B. Schulz, Martin Schweiger, Cosimo D'Andrea, Gianluca Valentini, Jörg Peter, Rinaldo Cubeddu, Simon Arridge, Wolfhard Semmler

    Can time-resolved, high-resolution data as acquired by an intensified gated CCD camera (ICCD) aid in the tomographic reconstruction of fluorescence concentration? Usually it is argued that fluorescence is a linear process and thus does not require non-linear, time-dependent reconstructions algorithms, unless absorption and scattering coefficients need to be determined as well. Furthermore, the acquisition of a number of time frames is usually prohibitive for fluorescence measurements, at least in small animals, due to the increased total measurement time. On the other hand, it is obvious that diffusion is less pronounced in images at early gates, due to selective imaging of photons of lower scatter order. This will be the case also for photons emitted by fluorescent sources. Early-gated imaging might increase the contrast in acquired images and could possibly improve fluorescence localization. Herein, we present early gated fluorescence images obtained from phantoms and compare them to continuously acquired data. Increased contrast between background and signal maximum can be observed in time-gated images as compared to continuous data. To make use of the properties exhibited by early gated frames, it is necessary to use a modified reconstruction algorithm. We propose a variant of the well-known Born approximation to the diffusion equation that allows to take into account single time frames. The system matrix for the time-dependent Born approach is more complex to calculate, however the complexity of the actual inverse problem (and the acquisition times) of single-frame reconstructions remains the same as compared to continuous mode.

  • Development and Initial Results of a Tomographic Dual-Modality Positron/Optical Small Animal Imager

    by Joerg Peter, Daniel Unholtz, Ralf B. Schulz, Wolfhard Semmler

    A novel concept for integrating PET and optical detection devices in a single instrument is presented. It is intended for simultaneous tomographic imaging of positron-labeled and optical probes in vivo. The optical imaging units consist of a microlens array (MLA) defining the field-of-view, a large area CMOS chip for light detection, and a transferable filter for excitation light blocking. The CMOS sensor array is positioned at the focal plane of the MLA. In a final design proposal optimized for fully tomographic mouse imaging the optical detector size is chosen to be 8.2 mm (transaxially) x 82.0 mm (axially) and has an effective thickness of 3.0 mm. A multitude of such ultra-thin detectors is allocated orthogonally with respect to the imaged object's long axis for tomographic whole body data acquisition of small animals (mice). PET detector blocks are located in radial extension to the optical detectors and mounted on a common rotatable gantry. Laser(s) used for probe excitation are positioned at radial extension behind the PET rings and are translatable along the axis of rotation allowing for arbitrary probe excitation and improved spatial sampling, particularly of the optical system. Both, the optical detector arrangement as well as the PET detectors are mounted so that excitation light can be introduced through the gaps between individual blocks. An experimental setup has been assembled in our laboratory and phantom data were acquired.