Ekkehard Euler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ekkehard Euler has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Synek
Institute of Lightweight Design and Structural Biomechanics, TU Wien, Vienna, Austria
2 shared publications - Sebastian Felix Baumbach
Department of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital Munich, Ludwig-Maximilians-Universität München, Munich, Germany
2 shared publications - Yan Chevalier
Department of Orthopedic Surgery, Physical Medicine and Rehabilitation, University Hospital of Munich (LMU), Campus Grosshadern, Marchioninistrasse 15, D-81377 Munich, Germany
2 shared publications - Andreas Voelkl
Department of Hematology and Oncology, University Hospital Munich, Ludwig-Maximilians-University, Ziemsenstr. 1, Munich 80336, Germany
1 shared publication D. Kotsianos
Klinikum Innenstadt, Universität München
1 shared publicationDorothea Kotsianos
1 shared publication
Latest Publications
- Open Access
- 9 March 2017
- Published by Springer Nature in BMC Medical Imaging
- Vol. 17 (1) , 1-9
Analysis of the three-dimensional anatomical variance of the distal radius using 3D shape models
Various medical fields rely on detailed anatomical knowledge of the distal radius. Current studies are limited to two-dimensional analysis and biased by varying measurement locations. The aims were to 1) generate 3D shape models of the distal radius and investigate variations in the 3D shape, 2) generate and assess morphometrics in standardized cut planes, and 3) test the model’s classification accuracy. The local radiographic database was screened for CT-scans of intact radii. 1) The data sets were segmented and 3D surface models generated. Statistical 3D shape models were computed (overall, gender and side separate) and the 3D shape variation assessed by evaluating the number of modes. 2) Anatomical landmarks were assigned and used to define three standardized cross-sectional cut planes perpendicular to the main axis. Cut planes were generated for the mean shape models and each individual radius. For each cut plane, the following morphometric parameters were calculated and compared: maximum width and depth, perimeter and area. 3) The overall shape model was utilized to evaluate the predictive value (leave one out cross validation) for gender and side identification within the study population. Eighty-six radii (45 left, 44% female, 40 ± 18 years) were included. 1) Overall, side and gender specific statistical 3D models were successfully generated. The first mode explained 37% of the overall variance. Left radii had a higher shape variance (number of modes: 20 female / 23 male) compared to right radii (number of modes: 6 female / 6 male). 2) Standardized cut planes could be defined using anatomical landmarks. All morphometric parameters decreased from distal to proximal. Male radii were larger than female radii with no significant side difference. 3) The overall shape model had a combined median classification probability for side and gender of 80%. Statistical 3D shape models of the distal radius can be generated using clinical CT-data sets. These models can be used to assess overall bone variance, define and analyze standardized cut-planes, and identify the gender of an unknown sample. These data highlight the potential of shape models to assess the 3D anatomy and anatomical variance of human bones.
- 9 March 2017
- Published by Springer Nature in BMC Medical Imaging
- Vol. 17 (1) , 1-9
Open AccessAnalysis of the three-dimensional anatomical variance of the distal radius using 3D shape models
Various medical fields rely on detailed anatomical knowledge of the distal radius. Current studies are limited to two-dimensional analysis and biased by varying measurement locations. The aims were to 1) generate 3D shape models of the distal radius and investigate variations in the 3D shape, 2) generate and assess morphometrics in standardized cut planes, and 3) test the model’s classification accuracy. The local radiographic database was screened for CT-scans of intact radii. 1) The data sets were segmented and 3D surface models generated. Statistical 3D shape models were computed (overall, gender and side separate) and the 3D shape variation assessed by evaluating the number of modes. 2) Anatomical landmarks were assigned and used to define three standardized cross-sectional cut planes perpendicular to the main axis. Cut planes were generated for the mean shape models and each individual radius. For each cut plane, the following morphometric parameters were calculated and compared: maximum width and depth, perimeter and area. 3) The overall shape model was utilized to evaluate the predictive value (leave one out cross validation) for gender and side identification within the study population. Eighty-six radii (45 left, 44% female, 40 ± 18 years) were included. 1) Overall, side and gender specific statistical 3D models were successfully generated. The first mode explained 37% of the overall variance. Left radii had a higher shape variance (number of modes: 20 female / 23 male) compared to right radii (number of modes: 6 female / 6 male). 2) Standardized cut planes could be defined using anatomical landmarks. All morphometric parameters decreased from distal to proximal. Male radii were larger than female radii with no significant side difference. 3) The overall shape model had a combined median classification probability for side and gender of 80%. Statistical 3D shape models of the distal radius can be generated using clinical CT-data sets. These models can be used to assess overall bone variance, define and analyze standardized cut-planes, and identify the gender of an unknown sample. These data highlight the potential of shape models to assess the 3D anatomy and anatomical variance of human bones.
- Open Access
- 10 March 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-7
Using self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
Symptomatic extensor tendon irritation is a frequent complication in volar plate osteosynthesis of distal radius fractures. It is typically caused by dorsal screw protrusion and overdrilling of the dorsal cortex. The use of self-drilling locking screws (SDLS) could overcome both causes. The practical applicability of SDLS depends on two prerequisites: (1) the feasibility of preoperative distal screw length determination, and (2) sufficient primary biomechanical stability of SDLS compared to standard locking screws (SLS). We first assessed the feasibility of preoperative screw length determination (1): Distal radius width, depth and distal screw lengths were measured in 38 human radii. Correlations between distal radius width and depth were assessed, a cluster analysis (Ward’s method and squared Euclidean distance) for distal radius width conducted, and intra-cluster screw lengths analyzed (ANOVA). The biomechanical performance of SDLS (2) was assessed by comparison to SLS in a distal radius fracture model (AO-23 A3). 75 % distal screw length was chosen for both groups to simulate a worst-case scenario. Uniaxial compression tests were conducted to measure stiffness, elastic limit, maximum force and residual tilt. Statistics comprised of independent sample t-tests and a Bonferroni correction (p < 0.0125). (1) Distal radius width and depth showed a high correlation (R 2 = 0.79; p < 0.001). Three distal radius width clusters could be identified: small 36.9 mm. ANOVA and Tukey post-hoc analysis revealed significantly different volar-dorsal depths (p < 0.05) for nearly all screws. (2) To assess biomechanical stability nine specimens were tested each; no significant differences were found between the SDLS and SLS groups. This feasibility study demonstrates that (1) distal radius width can be used as a predictor for distal screw length and (2) that SDLS provides mechanical stability equivalent to SLS. These results highlight the feasibility of applying SDLS screws in volar plate osteosynthesis at least in extraarticular fractures.
- 10 March 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 1-7
Open AccessUsing self-drilling screws in volar plate osteosynthesis for distal radius fractures: a feasibility study
Symptomatic extensor tendon irritation is a frequent complication in volar plate osteosynthesis of distal radius fractures. It is typically caused by dorsal screw protrusion and overdrilling of the dorsal cortex. The use of self-drilling locking screws (SDLS) could overcome both causes. The practical applicability of SDLS depends on two prerequisites: (1) the feasibility of preoperative distal screw length determination, and (2) sufficient primary biomechanical stability of SDLS compared to standard locking screws (SLS). We first assessed the feasibility of preoperative screw length determination (1): Distal radius width, depth and distal screw lengths were measured in 38 human radii. Correlations between distal radius width and depth were assessed, a cluster analysis (Ward’s method and squared Euclidean distance) for distal radius width conducted, and intra-cluster screw lengths analyzed (ANOVA). The biomechanical performance of SDLS (2) was assessed by comparison to SLS in a distal radius fracture model (AO-23 A3). 75 % distal screw length was chosen for both groups to simulate a worst-case scenario. Uniaxial compression tests were conducted to measure stiffness, elastic limit, maximum force and residual tilt. Statistics comprised of independent sample t-tests and a Bonferroni correction (p < 0.0125). (1) Distal radius width and depth showed a high correlation (R 2 = 0.79; p < 0.001). Three distal radius width clusters could be identified: small 36.9 mm. ANOVA and Tukey post-hoc analysis revealed significantly different volar-dorsal depths (p < 0.05) for nearly all screws. (2) To assess biomechanical stability nine specimens were tested each; no significant differences were found between the SDLS and SLS groups. This feasibility study demonstrates that (1) distal radius width can be used as a predictor for distal screw length and (2) that SDLS provides mechanical stability equivalent to SLS. These results highlight the feasibility of applying SDLS screws in volar plate osteosynthesis at least in extraarticular fractures.
- Open Access
- 1 January 2014
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 8 (1) , 28
Necrotizing fasciitis in a young patient with acute myeloid leukemia – a diagnostic challenge
Necrotizing fasciitis is characterized by a fulminant destruction of the soft tissue with an alarmingly high mortality rate. One of the main reasons for the continued high mortality is due to the challenge to punctual recognize and diagnose this disease, as specific cutaneous signs can vary or even be missing early in its evolution – especially in case of simultaneous first manifestation of an acute leukemia.
- 1 January 2014
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 8 (1) , 28
Open AccessNecrotizing fasciitis in a young patient with acute myeloid leukemia – a diagnostic challenge
Necrotizing fasciitis is characterized by a fulminant destruction of the soft tissue with an alarmingly high mortality rate. One of the main reasons for the continued high mortality is due to the challenge to punctual recognize and diagnose this disease, as specific cutaneous signs can vary or even be missing early in its evolution – especially in case of simultaneous first manifestation of an acute leukemia.
- 31 March 2011
- Published by Springer Nature
- p. 541-546
Open Extremity Fractures
- 1 July 2004
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 6 (S02) , S185-S190
3D-Bildwandler?Erfahrungen zu Aufwand und Benefit
- 1 July 2004
- Published by Springer Nature in Trauma und Berufskrankheit
- Vol. 6 (S02) , S185-S190
3D-Bildwandler?Erfahrungen zu Aufwand und Benefit
- Open Access
- 1 January 2004
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 9 (1-2) , 27-38
C-arm-based mobile computed tomography: a comparison with established imaging on the basis of simulated treatments of talus neck fractures in a cadaveric study
Objective: To analyse the image quality and diagnostic effectiveness of a new C-arm-based 3D imaging method (C-arm-CT) for intraoperative evaluation of screw osteosyntheses adjacent to a peripheral joint. Materials and Methods: Insertion of screws into four cadaveric specimens simulated the surgical treatment of talus neck fractures. Ten orthopedic surgeons and 10 radiologists evaluated X-ray, C-arm fluoroscopy, C-arm-CT and CT images. Results: The best image quality was obtained with X-rays (p < 0.001), followed by C-arm fluoroscopy (2D) and CT, with the C-arm-CT (3D) being rated lowest (p < 0.001). The most correct diagnoses were obtained with CT and C-arm-CT (with no statistical difference between them), while C-arm-fluoroscopy was inferior (p < 0.001) and X-rays were the worst (p < 0.05). Conclusions: Even if the image quality of C-arm-CT is definitely inferior to that of CT, screw misplacements can be reliably detected using C-arm-CT. As compared to the current standard procedures (intraoperative fluoroscopy and postoperative radiography), C-arm-CT performed better. C-arm-CT is ideally suited to the intraoperative diagnosis of high-contrast inquiries like bone fragments and OS material, especially at the extremities. Coupling of the new 3D imaging to existing navigation systems is possible. C-arm-CT will support the further development and implementation of open and minimally invasive surgical procedures.
- 1 January 2004
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 9 (1-2) , 27-38
Open AccessC-arm-based mobile computed tomography: a comparison with established imaging on the basis of simulated treatments of talus neck fractures in a cadaveric study
Objective: To analyse the image quality and diagnostic effectiveness of a new C-arm-based 3D imaging method (C-arm-CT) for intraoperative evaluation of screw osteosyntheses adjacent to a peripheral joint. Materials and Methods: Insertion of screws into four cadaveric specimens simulated the surgical treatment of talus neck fractures. Ten orthopedic surgeons and 10 radiologists evaluated X-ray, C-arm fluoroscopy, C-arm-CT and CT images. Results: The best image quality was obtained with X-rays (p < 0.001), followed by C-arm fluoroscopy (2D) and CT, with the C-arm-CT (3D) being rated lowest (p < 0.001). The most correct diagnoses were obtained with CT and C-arm-CT (with no statistical difference between them), while C-arm-fluoroscopy was inferior (p < 0.001) and X-rays were the worst (p < 0.05). Conclusions: Even if the image quality of C-arm-CT is definitely inferior to that of CT, screw misplacements can be reliably detected using C-arm-CT. As compared to the current standard procedures (intraoperative fluoroscopy and postoperative radiography), C-arm-CT performed better. C-arm-CT is ideally suited to the intraoperative diagnosis of high-contrast inquiries like bone fragments and OS material, especially at the extremities. Coupling of the new 3D imaging to existing navigation systems is possible. C-arm-CT will support the further development and implementation of open and minimally invasive surgical procedures.