Shuichi Umezawa
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuichi Umezawa has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Koichi Yonezawa
Central Research Institute of Electrical Power Industry, Abiko 270-1194, Japan
5 shared publications - Katsuhiko Sugita
Tokyo Electric Power Company Holdings, Inc., 4-1 Egasaki-cho, Tsurumiki-ku, Yokohama 230-8510, Kanagawa, Japan
3 shared publications - Shuichi Ohmori3 shared publications
- Genki Nakai
Graduate School of Engineering Science, Osaka University, 1-3, Machikanayama-cho, Toyonaka 560-8531, Osaka, Japan
2 shared publications - Junichi Sakamoto2 shared publications
Kazuyasu Sugiyama
Graduate School of Engineering Science, Osaka University, 1-3, Machikanayama-cho, Toyonaka 560-8531, Osaka, Japan
2 shared publications
Latest Publications
- Open Access
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 89 (921) , 22-00267
Flow measurement of five seal air pipes at a coal mill using the heater method at a coal fired power plant and numerical analysis of one of the pipes with curvature
High efficiency coal fired power plants are expected to operate at a certain rate due to low generated electricity costs. In coal fired power plants, coal mills are important machinery that pulverize the coal and supplies the coal powder to the boiler. To protect the bearings from coal dust, seal air is added. The seal air is supplied from one air compressor to each position of several coal mills at a target power station. An imbalance in its flowrate can lead to coal mill failures, thereby affecting the operation of coal fired power plants. In order to diagnose any problems with the operation of a coal mill immediately after maintenance, the heater method was used to measure the seal air at five locations from the outside of the supply pipes. The heater method is possible to measure the flow rate of compressed air and steam in the pipes from the outside of the pipes without any modification of the pipes, and has previously been applied to the measurement of cooling air flow in gas turbines. In the present case, three pipes out of five measuring points have curvature, so that a numerical analysis was carried out to verify whether the heater method is valid. Due to the effects of the corona disaster and other work, the measurement schedule at the power station was restricted and the installation, measurement and removal of instruments at five locations was carried out in a period of five days. As a result, it was confirmed that the seal air flowrate at each of the coal mill locations was normal value and that there were no problems with operation.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 89 (921) , 22-00267
Open AccessFlow measurement of five seal air pipes at a coal mill using the heater method at a coal fired power plant and numerical analysis of one of the pipes with curvature
High efficiency coal fired power plants are expected to operate at a certain rate due to low generated electricity costs. In coal fired power plants, coal mills are important machinery that pulverize the coal and supplies the coal powder to the boiler. To protect the bearings from coal dust, seal air is added. The seal air is supplied from one air compressor to each position of several coal mills at a target power station. An imbalance in its flowrate can lead to coal mill failures, thereby affecting the operation of coal fired power plants. In order to diagnose any problems with the operation of a coal mill immediately after maintenance, the heater method was used to measure the seal air at five locations from the outside of the supply pipes. The heater method is possible to measure the flow rate of compressed air and steam in the pipes from the outside of the pipes without any modification of the pipes, and has previously been applied to the measurement of cooling air flow in gas turbines. In the present case, three pipes out of five measuring points have curvature, so that a numerical analysis was carried out to verify whether the heater method is valid. Due to the effects of the corona disaster and other work, the measurement schedule at the power station was restricted and the installation, measurement and removal of instruments at five locations was carried out in a period of five days. As a result, it was confirmed that the seal air flowrate at each of the coal mill locations was normal value and that there were no problems with operation.
- Open Access
- 1 January 2022
- Published by Japan Society of Mechanical Engineers in Mechanical Engineering Journal
- Vol. 9 (4) , 22-00030
Flowrate measurement of gas turbine cooling air at an advanced combined cycle power plant using the heater method for plant operation and maintenance
At a combined cycle power plant, gas turbine cooling air flowrate data is required for operation and maintenance because it is an important for analyzing not only the temperature of both stators and blades but also plant efficiency. However, it is very difficult to measure the data. An ultrasonic flowmeter cannot be used since the measurement position becomes hot, usually exceeding 300 degrees centigrade. An insert type flowmeter is also difficult to use as it requires additional pipe processing for installation and also causes a pressure loss. Accordingly, we tried to use the heater method, which we proposed and validated in our previous papers. In this method, a circumferential heater is attached to the outside of a pipe and then the axial temperature distribution along the outside of the pipe, which is influenced by the fluid velocity in the pipe, is measured by thermocouples. The velocity is analyzed on the basis of the temperature distribution along the pipe. Measurements were conducted for two kinds of cooling air pipe at an advanced combined cycle power plant. In one, cooling air is extracted from the 13th stage of a compressor and supplied to the 2nd stators of the gas turbine; in the other, cooling air is extracted from the 9th stage of the compressor and supplied to the 3rd stators of the gas turbine. As a result, it was clarified that the cooling air flowrate had a positive dependence on atmospheric temperature at the plant. The dependence was also compared to that of a tit 1,600 degrees centigrade-class combined cycle power plant, with a power output of 700 MW.
- 1 January 2022
- Published by Japan Society of Mechanical Engineers in Mechanical Engineering Journal
- Vol. 9 (4) , 22-00030
Open AccessFlowrate measurement of gas turbine cooling air at an advanced combined cycle power plant using the heater method for plant operation and maintenance
At a combined cycle power plant, gas turbine cooling air flowrate data is required for operation and maintenance because it is an important for analyzing not only the temperature of both stators and blades but also plant efficiency. However, it is very difficult to measure the data. An ultrasonic flowmeter cannot be used since the measurement position becomes hot, usually exceeding 300 degrees centigrade. An insert type flowmeter is also difficult to use as it requires additional pipe processing for installation and also causes a pressure loss. Accordingly, we tried to use the heater method, which we proposed and validated in our previous papers. In this method, a circumferential heater is attached to the outside of a pipe and then the axial temperature distribution along the outside of the pipe, which is influenced by the fluid velocity in the pipe, is measured by thermocouples. The velocity is analyzed on the basis of the temperature distribution along the pipe. Measurements were conducted for two kinds of cooling air pipe at an advanced combined cycle power plant. In one, cooling air is extracted from the 13th stage of a compressor and supplied to the 2nd stators of the gas turbine; in the other, cooling air is extracted from the 9th stage of the compressor and supplied to the 3rd stators of the gas turbine. As a result, it was clarified that the cooling air flowrate had a positive dependence on atmospheric temperature at the plant. The dependence was also compared to that of a tit 1,600 degrees centigrade-class combined cycle power plant, with a power output of 700 MW.
- Open Access
- 16 July 2021
- Published by ASME International
Numerical Study of Influence of Rotor Tip Gap Increase due to Age Deterioration in 3-Stage Gas Turbine
- 16 July 2021
- Published by ASME International
Open AccessNumerical Study of Influence of Rotor Tip Gap Increase due to Age Deterioration in 3-Stage Gas Turbine
- Open Access
- 16 July 2021
- Published by ASME International
Unsteady Flow Simulation Through Stator-Rotor Blade Rows in Intermediate-Pressure Steam Turbines With Cutback Blades
Steam turbines in thermal power plants require long-term safety for stable power supply and high power generation efficiency with the save of fossil fuel, whereas the turbine blades are gradually deteriorated during the long-term operation. Because such secular-changed blades decrease the turbine efficiency and reliability, the maintenance, repair, and overhaul (MRO) of the steam
- 16 July 2021
- Published by ASME International
Open AccessUnsteady Flow Simulation Through Stator-Rotor Blade Rows in Intermediate-Pressure Steam Turbines With Cutback Blades
Steam turbines in thermal power plants require long-term safety for stable power supply and high power generation efficiency with the save of fossil fuel, whereas the turbine blades are gradually deteriorated during the long-term operation. Because such secular-changed blades decrease the turbine efficiency and reliability, the maintenance, repair, and overhaul (MRO) of the steam
- Open Access
- 16 July 2021
- Published by ASME International
Numerical Study of Influence of Rotor Tip Gap Increase due to Age Deterioration in 3-Stage Gas Turbine
Gas turbine combined cycle plays an important role as an electric power generation system. It is important to keep the efficiency high through years enough to cover the power demand and to reduce the greenhouse emission. Recently, frequencies of partial load operation and daily start and stop of gas turbines are increasing due to rapid increase of renewable energy, such as
- 16 July 2021
- Published by ASME International
Open AccessNumerical Study of Influence of Rotor Tip Gap Increase due to Age Deterioration in 3-Stage Gas Turbine
Gas turbine combined cycle plays an important role as an electric power generation system. It is important to keep the efficiency high through years enough to cover the power demand and to reduce the greenhouse emission. Recently, frequencies of partial load operation and daily start and stop of gas turbines are increasing due to rapid increase of renewable energy, such as
- 14 September 2018
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (1)
Degradation of Aerodynamic Performance of an Intermediate-Pressure Steam Turbine Due to Erosion of Nozzle Guide Vanes and Rotor Blades
Deteriorations of nozzle guide vanes (NGVs) and rotor blades of a steam turbine through a long-time operation usually decrease a thermal efficiency and a power output of the turbine. In this study, influences of blade deformations due to erosion are discussed. Experiments were carried out in order to validate numerical simulations using a commercial software ANSYS-cfx. The numerical results showed acceptable agreements with experimental results. Variation of flow characteristics in the first stage of the intermediate pressure steam turbine is examined using numerical simulations. Geometries of the NGVs and the rotor blades are measured using a 3D scanner during an overhaul. The old NGVs and the rotor blades, which were used in operation, were eroded through the operation. The erosion of the NGVs leaded to increase of the throat area of the nozzle. The numerical results showed that rotor inlet velocity through the old NGVs became smaller and the flow angle of attack to the rotor blade leading edge became smaller. Consequently, the rotor power decreased significantly. Influences of the flow angle of at the rotor inlet were examined by parametric calculations and results showed that the angle of attack was an important parameter to determine the rotor performance. In addition, the influence of the deformation of the rotor blade was examined. The results showed that the degradation of the rotor performance decreased in accordance with the decrease of blade surface area.
- 14 September 2018
- Published by Wiley in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (1)
Degradation of Aerodynamic Performance of an Intermediate-Pressure Steam Turbine Due to Erosion of Nozzle Guide Vanes and Rotor Blades
Deteriorations of nozzle guide vanes (NGVs) and rotor blades of a steam turbine through a long-time operation usually decrease a thermal efficiency and a power output of the turbine. In this study, influences of blade deformations due to erosion are discussed. Experiments were carried out in order to validate numerical simulations using a commercial software ANSYS-cfx. The numerical results showed acceptable agreements with experimental results. Variation of flow characteristics in the first stage of the intermediate pressure steam turbine is examined using numerical simulations. Geometries of the NGVs and the rotor blades are measured using a 3D scanner during an overhaul. The old NGVs and the rotor blades, which were used in operation, were eroded through the operation. The erosion of the NGVs leaded to increase of the throat area of the nozzle. The numerical results showed that rotor inlet velocity through the old NGVs became smaller and the flow angle of attack to the rotor blade leading edge became smaller. Consequently, the rotor power decreased significantly. Influences of the flow angle of at the rotor inlet were examined by parametric calculations and results showed that the angle of attack was an important parameter to determine the rotor performance. In addition, the influence of the deformation of the rotor blade was examined. The results showed that the degradation of the rotor performance decreased in accordance with the decrease of blade surface area.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2016.21, A122
Degradation Effects on a Performance of Rotor and Stator Blades in a Gas Turbine First Stage
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2016.21, A122
Degradation Effects on a Performance of Rotor and Stator Blades in a Gas Turbine First Stage
- Open Access
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2016.21, D132
Ultrasonic beam focusing for steam flowrate measurement in high temperature metal pipe
Clamp-on steam flowmeter was is developed by ultrasonic beam focusing technique. In the conventional tuft method, three individual sensors are arranged as receivers to estimate the sound pressure distribution. However, the alignment and the sensitivity of the sensors are required to improve. Therefore, focusing sensor array was newly manufactured. Besides, the signal to noise ratio was improved by applying the damping material which attenuates the guided wave. Then the steam flowrate measurement experiment was conducted by using the developed ultrasonic sensors and damping material. The results reveal the possiblility of steam flowrate measurement by ultrasonic tuft method.
- 1 January 2016
- Published by Japan Society of Mechanical Engineers in The Proceedings of the National Symposium on Power and Energy Systems
- Vol. 2016.21, D132
Open AccessUltrasonic beam focusing for steam flowrate measurement in high temperature metal pipe
Clamp-on steam flowmeter was is developed by ultrasonic beam focusing technique. In the conventional tuft method, three individual sensors are arranged as receivers to estimate the sound pressure distribution. However, the alignment and the sensitivity of the sensors are required to improve. Therefore, focusing sensor array was newly manufactured. Besides, the signal to noise ratio was improved by applying the damping material which attenuates the guided wave. Then the steam flowrate measurement experiment was conducted by using the developed ultrasonic sensors and damping material. The results reveal the possiblility of steam flowrate measurement by ultrasonic tuft method.