Fred M. Discenzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fred M. Discenzo has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Angela L. Ridgel
Kent State University
2 shared publications - Kenneth A. Loparo
Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH, USA
2 shared publications - Benjamin L. Walter
Center for Neurological Restoration, Neurological Institute, Cleveland Clinic, 9500 Euclid Ave., Cleveland, OH 44195, USA
1 shared publication - Dan Carnahan
Rockwell Automation
1 shared publication Daniel Carnahan
1 shared publication- Dukki Chung
Rockwell Automation
1 shared publication
Latest Publications
- 31 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 24 (11) , 1254-1264
Test and Validation of a Smart Exercise Bike for Motor Rehabilitation in Individuals With Parkinson’s Disease
To assess and validate the Smart Exercise Bike designed for Parkinson's Disease (PD) rehabilitation, 47 individuals with PD were randomly assigned to either the static or dynamic cycling group, and completed three sessions of exercise. Heart rate, cadence and power data were captured and recorded for each patient during exercise. Motor function for each subject was assessed with the UPDRS Motor III test before and after the three exercise sessions to evaluate the effect of exercise on functional abilities. Individuals who completed three sessions of dynamic cycling showed an average of 13.8% improvement in the UPDRS, while individuals in the static cycling group worsened by 1.6% in UPDRS. To distinguish the static and dynamic cycling groups by biomechanical and physiological features, the complexity of the recorded signals (cadence, power, and heart rate) was examined using approximate entropy (ApEn), sample entropy (SaEn) and spectral entropy (SpEn) as measures of variability. A multiple linear regression (MLR) model was used to relate these features to changes in motor function as measured by the UPDRS Motor III scale. Pattern variability in cadence was greater in the dynamic group when compared to the static group. In contrast, variability in power was greater for the static group. UPDRS Motor III scores predicted from the pattern variability data were correlated to measured scores in both groups. These results support our previous study which explained how variability analysis results for biomechanical and physiological parameters of exercise can be used to predict improvements in motor function.
- 31 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 24 (11) , 1254-1264
Test and Validation of a Smart Exercise Bike for Motor Rehabilitation in Individuals With Parkinson’s Disease
To assess and validate the Smart Exercise Bike designed for Parkinson's Disease (PD) rehabilitation, 47 individuals with PD were randomly assigned to either the static or dynamic cycling group, and completed three sessions of exercise. Heart rate, cadence and power data were captured and recorded for each patient during exercise. Motor function for each subject was assessed with the UPDRS Motor III test before and after the three exercise sessions to evaluate the effect of exercise on functional abilities. Individuals who completed three sessions of dynamic cycling showed an average of 13.8% improvement in the UPDRS, while individuals in the static cycling group worsened by 1.6% in UPDRS. To distinguish the static and dynamic cycling groups by biomechanical and physiological features, the complexity of the recorded signals (cadence, power, and heart rate) was examined using approximate entropy (ApEn), sample entropy (SaEn) and spectral entropy (SpEn) as measures of variability. A multiple linear regression (MLR) model was used to relate these features to changes in motor function as measured by the UPDRS Motor III scale. Pattern variability in cadence was greater in the dynamic group when compared to the static group. In contrast, variability in power was greater for the static group. UPDRS Motor III scores predicted from the pattern variability data were correlated to measured scores in both groups. These results support our previous study which explained how variability analysis results for biomechanical and physiological parameters of exercise can be used to predict improvements in motor function.
- 11 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (3) , 1650-1658
Design and Development of a Smart Exercise Bike for Motor Rehabilitation in Individuals With Parkinson's Disease
Recent studies in rehabilitation of Parkinson's disease (PD) have shown that cycling on a tandem bike at a high pedaling rate can reduce the symptoms of the disease. In this paper, a smart motorized bicycle has been designed and built for assisting Parkinson's patients with exercise to improve motor function. The exercise bike can accurately control the rider's experience at an accelerated pedaling rate, while capturing real-time test data. Here, the design and development of the electronics and hardware as well as the software and control algorithms are presented. Two control algorithms have been developed for the bike: one that implements an inertia load (static mode) and one that implements a speed reference (dynamic mode). In static mode, the bike operates as a regular exercise bike with programmable resistance (load) that captures and records the required signals, such as heart rate, cadence, and power. In dynamic mode, the bike operates at a user-selected speed (cadence) with programmable variability in speed that has been shown to be essential to achieve the desired motor performance benefits for PD patients. In addition, the flexible and extensible design of the bike permits readily changing the control algorithm and incorporating additional I/O as needed to provide a wide range of riding experiences. Furthermore, the network-enabled controller provides remote access to bike dand one that implements a speed reference (dynamic mode). In static mode, the bike operates as a regular exercise bike with programmable resistance (load) that captures and records the required signals, such as heart rate, cadence, and power. In dynamic mode, the bike operates at a user-selected speed (cadence) with programmable variability in speed that has been shown to be essential to achieve the desired motor performance benefits for PD patients. In addition, the flexible and extensible design of the bike permits readily changing the control algorithm and incorporating additional I/O as needed to provide a wide range of riding experiences. Furthermore, the network-enabled controller provides remote access to bike data during a ridingata during a riding session.
- 11 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 21 (3) , 1650-1658
Design and Development of a Smart Exercise Bike for Motor Rehabilitation in Individuals With Parkinson's Disease
Recent studies in rehabilitation of Parkinson's disease (PD) have shown that cycling on a tandem bike at a high pedaling rate can reduce the symptoms of the disease. In this paper, a smart motorized bicycle has been designed and built for assisting Parkinson's patients with exercise to improve motor function. The exercise bike can accurately control the rider's experience at an accelerated pedaling rate, while capturing real-time test data. Here, the design and development of the electronics and hardware as well as the software and control algorithms are presented. Two control algorithms have been developed for the bike: one that implements an inertia load (static mode) and one that implements a speed reference (dynamic mode). In static mode, the bike operates as a regular exercise bike with programmable resistance (load) that captures and records the required signals, such as heart rate, cadence, and power. In dynamic mode, the bike operates at a user-selected speed (cadence) with programmable variability in speed that has been shown to be essential to achieve the desired motor performance benefits for PD patients. In addition, the flexible and extensible design of the bike permits readily changing the control algorithm and incorporating additional I/O as needed to provide a wide range of riding experiences. Furthermore, the network-enabled controller provides remote access to bike dand one that implements a speed reference (dynamic mode). In static mode, the bike operates as a regular exercise bike with programmable resistance (load) that captures and records the required signals, such as heart rate, cadence, and power. In dynamic mode, the bike operates at a user-selected speed (cadence) with programmable variability in speed that has been shown to be essential to achieve the desired motor performance benefits for PD patients. In addition, the flexible and extensible design of the bike permits readily changing the control algorithm and incorporating additional I/O as needed to provide a wide range of riding experiences. Furthermore, the network-enabled controller provides remote access to bike data during a ridingata during a riding session.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-8
Agent Virtual Machine for Shipboard Automation Systems
We are interested in providing an agent infrastructure for truly distributed control. Requirements include multiple language implementations so that this agent host environment can exist in both real-time controllers and contain the ability to operate with external agent systems. Our first infrastructure, the Autonomous Cooperative System (ACS), accomplished these goals, but presented other issues. Although ACS has been successfully deployed on commercial controllers, new releases of controllers will cause complications in the evolution of the software and adoption of future functionality. We need to establish a formal integration procedure of the agent functionality with the controllers and to transform the underlying system into a fully integrated and open heterogeneous system. With an agent-enabled control firmware, we can make shipboard automation system o more distributed and survivable by essentially eliminating single point of failures.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19325517,p. 1-8
Agent Virtual Machine for Shipboard Automation Systems
We are interested in providing an agent infrastructure for truly distributed control. Requirements include multiple language implementations so that this agent host environment can exist in both real-time controllers and contain the ability to operate with external agent systems. Our first infrastructure, the Autonomous Cooperative System (ACS), accomplished these goals, but presented other issues. Although ACS has been successfully deployed on commercial controllers, new releases of controllers will cause complications in the evolution of the software and adoption of future functionality. We need to establish a formal integration procedure of the agent functionality with the controllers and to transform the underlying system into a fully integrated and open heterogeneous system. With an agent-enabled control firmware, we can make shipboard automation system o more distributed and survivable by essentially eliminating single point of failures.
- 1 July 2004
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 37 (10) , 233-238
Augmented reality supports real-time diagnosis and repair of shipboard systems
- 1 July 2004
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 37 (10) , 233-238
Augmented reality supports real-time diagnosis and repair of shipboard systems