Carole Kay Hayakawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Carole Kay Hayakawa has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Vasan Venugopalan
University of California, Irvine, Department of Chemical and Biomolecular Engineering, Irvine, California, United States
7 shared publications Jerome Spanier
University of California
4 shared publications- Janaka Ranasinghesagara
Univ. of Alberta (Canada)
2 shared publications - Jerome Spanier
University of California at Irvine
2 shared publications Adam R. Gardner
Beckman Laser Institute, Laser Microbeam and Medical Program, 1002 Health Sciences Road, Irvine, California 92697-3010bUniversity of California, Department of Chemical Engineering and Materials Science, 916 Engineering Tower, Irvine, California 92697-2575
1 shared publication- Anthony Joseph Durkin
University of California, Irvine, Beckman Laser Institute, Irvine, California, United States
1 shared publication
Latest Publications
- Open Access
- 11 February 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (118)
MieSimulatorGUI: A user-friendly tool to compute and visualize light scattering by spherical dielectric particles
- 11 February 2026
- Published by The Open Journal in Journal of Open Source Software
- Vol. 11 (118)
Open AccessMieSimulatorGUI: A user-friendly tool to compute and visualize light scattering by spherical dielectric particles
- Open Access
- 1 June 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (06) , 065001-14
Analysis of relative error in perturbation Monte Carlo simulations of radiative transport
Monte Carlo simulations have been broadly adopted by the biomedical optics community to simulate light propagation in scattering tissues on mesoscopic and macroscopic scales; i.e., on spatial scales comparable to and larger than the single scattering mean free path. Conventional Monte Carlo (cMC) simulations provide rigorous solutions to the radiative transport equation and can be configured for systems with complicated geometric and material features. However, cMC simulations can be computationally costly since this stochastic solver carries with it a solution uncertainty that scales as where is the number of photons simulated.1 Thus, any application that requires the execution of multiple cMC simulations; e.g., the resolution of an inverse problem, can easily have an associated computational cost that is impractical given the number of photons that must be simulated in order to obtain an estimate with sufficiently low uncertainty.- 1 June 2023
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 28 (06) , 065001-14
Open AccessAnalysis of relative error in perturbation Monte Carlo simulations of radiative transport
Monte Carlo simulations have been broadly adopted by the biomedical optics community to simulate light propagation in scattering tissues on mesoscopic and macroscopic scales; i.e., on spatial scales comparable to and larger than the single scattering mean free path. Conventional Monte Carlo (cMC) simulations provide rigorous solutions to the radiative transport equation and can be configured for systems with complicated geometric and material features. However, cMC simulations can be computationally costly since this stochastic solver carries with it a solution uncertainty that scales as where is the number of photons simulated.1 Thus, any application that requires the execution of multiple cMC simulations; e.g., the resolution of an inverse problem, can easily have an associated computational cost that is impractical given the number of photons that must be simulated in order to obtain an estimate with sufficiently low uncertainty. - Open Access
- 12 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (08) , 083005-19
MCCL: an open-source software application for Monte Carlo simulations of radiative transport
Monte Carlo (MC) methods to provide solutions for the radiative transport equation (RTE) originated at Los Alamos National Lab in 1946. At that time, the intent was to solve nuclear fission problems. The initial code base that was developed has subsequently evolved into the Monte Carlo N-Particle Transport (MCNP1) code.2 Since then, MC simulations of radiative transport have been used to solve problems in biomedical optics. The first paper documenting the use of MC to study light propagation in tissue was published by Wilson and Adam,3 and this was followed by Prahl et al.4 which served as a precursor to the seminal 1995 paper by Wang et al.5 that introduced the open-source MC Command Line application (MCML) code commemorated in this special issue.
- 12 April 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (08) , 083005-19
Open AccessMCCL: an open-source software application for Monte Carlo simulations of radiative transport
Monte Carlo (MC) methods to provide solutions for the radiative transport equation (RTE) originated at Los Alamos National Lab in 1946. At that time, the intent was to solve nuclear fission problems. The initial code base that was developed has subsequently evolved into the Monte Carlo N-Particle Transport (MCNP1) code.2 Since then, MC simulations of radiative transport have been used to solve problems in biomedical optics. The first paper documenting the use of MC to study light propagation in tissue was published by Wilson and Adam,3 and this was followed by Prahl et al.4 which served as a precursor to the seminal 1995 paper by Wang et al.5 that introduced the open-source MC Command Line application (MCML) code commemorated in this special issue.
- 26 April 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 38 (5) , 749-1
Comparative analysis of discrete and continuous absorption weighting estimators used in Monte Carlo simulations of radiative transport in turbid media: erratum
This erratum corrects the relative error plots and references in our paper [ J. Opt. Soc. Am. A 31, 301 (2014)JOAOD6 0740-3232 10.1364/JOSAA.31.000301 ].
- 26 April 2021
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 38 (5) , 749-1
Comparative analysis of discrete and continuous absorption weighting estimators used in Monte Carlo simulations of radiative transport in turbid media: erratum
This erratum corrects the relative error plots and references in our paper [ J. Opt. Soc. Am. A 31, 301 (2014)JOAOD6 0740-3232 10.1364/JOSAA.31.000301 ].
- Open Access
- 14 September 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (07) , 1-14
Optical sampling depth in the spatial frequency domain
We present a Monte Carlo (MC) method to determine depth-dependent probability distributions of photon visitation and detection for optical reflectance measurements performed in the spatial frequency domain (SFD). These distributions are formed using an MC simulation for radiative transport that utilizes a photon packet weighting procedure consistent with the two-dimensional spatial Fourier transform of the radiative transport equation. This method enables the development of quantitative metrics for SFD optical sampling depth in layered tissue and its dependence on both tissue optical properties and spatial frequency. We validate the computed depth-dependent probability distributions using SFD measurements in a layered phantom system with a highly scattering top layer of variable thickness supported by a highly absorbing base layer. We utilize our method to establish the spatial frequency-dependent optical sampling depth for a number of tissue types and also provide a general tool to determine such depths for tissues of arbitrary optical properties.
- 14 September 2018
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (07) , 1-14
Open AccessOptical sampling depth in the spatial frequency domain
We present a Monte Carlo (MC) method to determine depth-dependent probability distributions of photon visitation and detection for optical reflectance measurements performed in the spatial frequency domain (SFD). These distributions are formed using an MC simulation for radiative transport that utilizes a photon packet weighting procedure consistent with the two-dimensional spatial Fourier transform of the radiative transport equation. This method enables the development of quantitative metrics for SFD optical sampling depth in layered tissue and its dependence on both tissue optical properties and spatial frequency. We validate the computed depth-dependent probability distributions using SFD measurements in a layered phantom system with a highly scattering top layer of variable thickness supported by a highly absorbing base layer. We utilize our method to establish the spatial frequency-dependent optical sampling depth for a number of tissue types and also provide a general tool to determine such depths for tissues of arbitrary optical properties.
- Open Access
- 1 June 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (6) , 065003
Coupled forward-adjoint Monte Carlo simulation of spatial-angular light fields to determine optical sensitivity in turbid media
We present a coupled forward-adjoint Monte Carlo (cFAMC) method to determine the spatially resolved sensitivity distributions produced by optical interrogation of three-dimensional (3-D) tissue volumes. We develop a general computational framework that computes the spatial and angular distributions of the forward-adjoint light fields to provide accurate computations in mesoscopic tissue volumes. We provide full computational details of the cFAMC method and provide results for low- and high-scattering tissues probed using a single pair of optical fibers. We examine the effects of source-detector separation and orientation on the sensitivity distributions and consider how the degree of angular discretization used in the 3-D tissue model impacts the accuracy of the resulting absorption sensitivity profiles. We discuss the value of such computations for optical imaging and the design of optical measurements.
- 1 June 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (6) , 065003
Open AccessCoupled forward-adjoint Monte Carlo simulation of spatial-angular light fields to determine optical sensitivity in turbid media
We present a coupled forward-adjoint Monte Carlo (cFAMC) method to determine the spatially resolved sensitivity distributions produced by optical interrogation of three-dimensional (3-D) tissue volumes. We develop a general computational framework that computes the spatial and angular distributions of the forward-adjoint light fields to provide accurate computations in mesoscopic tissue volumes. We provide full computational details of the cFAMC method and provide results for low- and high-scattering tissues probed using a single pair of optical fibers. We examine the effects of source-detector separation and orientation on the sensitivity distributions and consider how the degree of angular discretization used in the 3-D tissue model impacts the accuracy of the resulting absorption sensitivity profiles. We discuss the value of such computations for optical imaging and the design of optical measurements.
- Open Access
- 20 January 2014
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 31 (2) , 301-311
Comparative analysis of discrete and continuous absorption weighting estimators used in Monte Carlo simulations of radiative transport in turbid media
We examine the relative error of Monte Carlo simulations of radiative transport that employ two commonly used estimators that account for absorption differently, either discretely, at interaction points, or continuously, between interaction points. We provide a rigorous derivation of these discrete and continuous absorption weighting estimators within a stochastic model that we show to be equivalent to an analytic model, based on the radiative transport equation (RTE). We establish that both absorption weighting estimators are unbiased and, therefore, converge to the solution of the RTE. An analysis of spatially resolved reflectance predictions provided by these two estimators reveals no advantage to either in cases of highly scattering and highly anisotropic media. However, for moderate to highly absorbing media or isotropically scattering media, the discrete estimator provides smaller errors at proximal source locations while the continuous estimator provides smaller errors at distal locations. The origin of these differing variance characteristics can be understood through examination of the distribution of exiting photon weights.
- 20 January 2014
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 31 (2) , 301-311
Open AccessComparative analysis of discrete and continuous absorption weighting estimators used in Monte Carlo simulations of radiative transport in turbid media
We examine the relative error of Monte Carlo simulations of radiative transport that employ two commonly used estimators that account for absorption differently, either discretely, at interaction points, or continuously, between interaction points. We provide a rigorous derivation of these discrete and continuous absorption weighting estimators within a stochastic model that we show to be equivalent to an analytic model, based on the radiative transport equation (RTE). We establish that both absorption weighting estimators are unbiased and, therefore, converge to the solution of the RTE. An analysis of spatially resolved reflectance predictions provided by these two estimators reveals no advantage to either in cases of highly scattering and highly anisotropic media. However, for moderate to highly absorbing media or isotropically scattering media, the discrete estimator provides smaller errors at proximal source locations while the continuous estimator provides smaller errors at distal locations. The origin of these differing variance characteristics can be understood through examination of the distribution of exiting photon weights.
- 6 July 2012
- Published by Springer Nature
- p. 419-434
Spatial/Angular Contributon Maps for Improved Adaptive Monte Carlo Algorithms
- 6 July 2012
- Published by Springer Nature
- p. 419-434
Spatial/Angular Contributon Maps for Improved Adaptive Monte Carlo Algorithms
- Open Access
- 1 January 2009
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 14 (5) , 054043-054043-12
Investigation of a probe design for facilitating the uses of the standard photon diffusion equation at short source-detector separations: Monte Carlo simulations
We design a special diffusing probe to investigate the optical properties of human skin in vivo. The special geometry of the probe enables a modified two-layer (MTL) diffusion model to precisely describe the photon transport even when the source-detector separation is shorter than 3 mean free paths. We provide a frequency domain comparison between the Monte Carlo model and the diffusion model in both the MTL geometry and conventional semiinfinite geometry. We show that using the Monte Carlo model as a benchmark method, the MTL diffusion theory performs better than the diffusion theory in the semiinfinite geometry. In addition, we carry out Monte Carlo simulations with the goal of investigating the dependence of the interrogation depth of this probe on several parameters including source-detector separation, sample optical properties, and properties of the diffusing high-scattering layer. From the simulations, we find that the optical properties of samples modulate the interrogation volume greatly, and the source-detector separation and the thickness of the diffusing layer are the two dominant probe parameters that impact the interrogation volume. Our simulation results provide design guidelines for a MTL geometry probe.
- 1 January 2009
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 14 (5) , 054043-054043-12
Open AccessInvestigation of a probe design for facilitating the uses of the standard photon diffusion equation at short source-detector separations: Monte Carlo simulations
We design a special diffusing probe to investigate the optical properties of human skin in vivo. The special geometry of the probe enables a modified two-layer (MTL) diffusion model to precisely describe the photon transport even when the source-detector separation is shorter than 3 mean free paths. We provide a frequency domain comparison between the Monte Carlo model and the diffusion model in both the MTL geometry and conventional semiinfinite geometry. We show that using the Monte Carlo model as a benchmark method, the MTL diffusion theory performs better than the diffusion theory in the semiinfinite geometry. In addition, we carry out Monte Carlo simulations with the goal of investigating the dependence of the interrogation depth of this probe on several parameters including source-detector separation, sample optical properties, and properties of the diffusing high-scattering layer. From the simulations, we find that the optical properties of samples modulate the interrogation volume greatly, and the source-detector separation and the thickness of the diffusing layer are the two dominant probe parameters that impact the interrogation volume. Our simulation results provide design guidelines for a MTL geometry probe.
- Open Access
- 1 January 2007
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (1) , 014030-014030-15
Perturbation and differential Monte Carlo methods for measurement of optical properties in a layered epithelial tissue model
The use of perturbation and differential Monte Carlo (pMC/dMC) methods in conjunction with nonlinear optimization algorithms were proposed recently as a means to solve inverse photon migration problems in regionwise heterogeneous turbid media. We demonstrate the application of pMC/dMC methods for the recovery of optical properties in a two-layer extended epithelial tissue model from experimental measurements of spatially resolved diffuse reflectance. The results demonstrate that pMC/dMC methods provide a rapid and accurate approach to solve two-region inverse photon migration problems in the transport regime, that is, on spatial scales smaller than a transport mean free path and in media where optical scattering need not dominate absorption. The pMC/dMC approach is found to be effective over a broad range of absorption (50 to 400%) and scattering (70 to 130%) perturbations. The recovery of optical properties from spatially resolved diffuse reflectance measurements is examined for different sets of source-detector separation. These results provide some guidance for the design of compact fiber-based probes to determine and isolate optical properties from both epithelial and stromal layers of superficial tissues.
- 1 January 2007
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 12 (1) , 014030-014030-15
Open AccessPerturbation and differential Monte Carlo methods for measurement of optical properties in a layered epithelial tissue model
The use of perturbation and differential Monte Carlo (pMC/dMC) methods in conjunction with nonlinear optimization algorithms were proposed recently as a means to solve inverse photon migration problems in regionwise heterogeneous turbid media. We demonstrate the application of pMC/dMC methods for the recovery of optical properties in a two-layer extended epithelial tissue model from experimental measurements of spatially resolved diffuse reflectance. The results demonstrate that pMC/dMC methods provide a rapid and accurate approach to solve two-region inverse photon migration problems in the transport regime, that is, on spatial scales smaller than a transport mean free path and in media where optical scattering need not dominate absorption. The pMC/dMC approach is found to be effective over a broad range of absorption (50 to 400%) and scattering (70 to 130%) perturbations. The recovery of optical properties from spatially resolved diffuse reflectance measurements is examined for different sets of source-detector separation. These results provide some guidance for the design of compact fiber-based probes to determine and isolate optical properties from both epithelial and stromal layers of superficial tissues.