Siyong Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Siyong Kim has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Chihray Liu
University of Florida
4 shared publicationsJatinder Palta
University of Florida
4 shared publicationsHeeteak Chung
University of Florida
3 shared publications- Jatinder R. Palta
Department of Radiation Oncology, University of Florida, Gainesville, FL, USA
3 shared publications Zhong Su
University of Florida
3 shared publicationsH. Chung
University of Florida
2 shared publications
Latest Publications
- 12 August 2009
- Published by Wiley in Medical Physics
- Vol. 36 (9Part1) , 3945-3954
Measurements of dose discrepancies due to inhomogeneities and radiographic contrast in balloon catheter brachytherapy
Recently, a device called MammoSite, consisting of a balloon and a catheter, was developed to perform partial-breast irradiation using a high-dose-rate (HDR) brachytherapy unit with ease and reproducibility. However, the actual dose to the skin does not agree well with the calculated dose by the treatment planning system because of the difference between the calculation condition and the real treatment condition (i.e., homogeneous water and full scatter condition vs contrast solution and lack of full scatter condition). In this study, the authors experimentally estimated dose discrepancies due to contrast and lack of full scatter in breast HDR brachytherapy with MammoSite. Using metal-oxide-semiconductor field-effect transistor detectors and a breast phantom, the dose discrepancies between the calculation and the treatment conditions were measured according to contrast concentration (10% and 20% volume ratios), balloon size (35 and 60 cm3), and source to detector distance ranging from 25 to 50 mm. The source was an Ir-192 isotope from Nucletron HDR unit. The dose discrepancies from the calculation condition due to both contrast and lack of full scatter combined ranged from about -1.4 +/- 2.5% to -18.2 +/- 2.0% in the studied cases (error bound is in two sided confidence interval of 80% based on Student's t distribution). In all cases, the effect of lack of full scatter was dominant to that of contrast and significant dose discrepancies existed between the calculation and the real treatment conditions, indicating that the actual skin dose is less than that which is currently calculated.
- 12 August 2009
- Published by Wiley in Medical Physics
- Vol. 36 (9Part1) , 3945-3954
Measurements of dose discrepancies due to inhomogeneities and radiographic contrast in balloon catheter brachytherapy
Recently, a device called MammoSite, consisting of a balloon and a catheter, was developed to perform partial-breast irradiation using a high-dose-rate (HDR) brachytherapy unit with ease and reproducibility. However, the actual dose to the skin does not agree well with the calculated dose by the treatment planning system because of the difference between the calculation condition and the real treatment condition (i.e., homogeneous water and full scatter condition vs contrast solution and lack of full scatter condition). In this study, the authors experimentally estimated dose discrepancies due to contrast and lack of full scatter in breast HDR brachytherapy with MammoSite. Using metal-oxide-semiconductor field-effect transistor detectors and a breast phantom, the dose discrepancies between the calculation and the treatment conditions were measured according to contrast concentration (10% and 20% volume ratios), balloon size (35 and 60 cm3), and source to detector distance ranging from 25 to 50 mm. The source was an Ir-192 isotope from Nucletron HDR unit. The dose discrepancies from the calculation condition due to both contrast and lack of full scatter combined ranged from about -1.4 +/- 2.5% to -18.2 +/- 2.0% in the studied cases (error bound is in two sided confidence interval of 80% based on Student's t distribution). In all cases, the effect of lack of full scatter was dominant to that of contrast and significant dose discrepancies existed between the calculation and the real treatment conditions, indicating that the actual skin dose is less than that which is currently calculated.
- 30 June 2007
- Published by Springer Nature
- p. 1766-1769
Is Dosimetric Effect of Leaf Width of MLC Clinically Significant in IMRT
- 30 June 2007
- Published by Springer Nature
- p. 1766-1769
Is Dosimetric Effect of Leaf Width of MLC Clinically Significant in IMRT
- 30 June 2007
- Published by Springer Nature
- p. 1941-1944
A new paradigm of IMRT plan evaluation with uncertainty volume histogram
- 30 June 2007
- Published by Springer Nature
- p. 1941-1944
A new paradigm of IMRT plan evaluation with uncertainty volume histogram
- 30 June 2007
- Published by Springer Nature
- p. 1880-1882
An image guided stereotactic body radiation therapy (IGSBRT) program of single fraction spine treatment
- 30 June 2007
- Published by Springer Nature
- p. 1880-1882
An image guided stereotactic body radiation therapy (IGSBRT) program of single fraction spine treatment
- 30 June 2007
- Published by Springer Nature
- p. 1819-1822
IMRT dose verification using the dose uncertainty prediction model
- 30 June 2007
- Published by Springer Nature
- p. 1819-1822
IMRT dose verification using the dose uncertainty prediction model
- 30 June 2007
- Published by Springer Nature
- p. 1815-1818
A Systematic Analysis of IMRT QA Results
- 1 January 2007
- Published by Springer Nature in IFMBE Proceedings
- p. 1945-1947
Characterization of a commercial add-on couch, HexaPOD™ 6D Robotic Treatment CouchTOP
- 1 January 2007
- Published by Springer Nature in IFMBE Proceedings
- p. 1945-1947
Characterization of a commercial add-on couch, HexaPOD™ 6D Robotic Treatment CouchTOP
- 14 January 2005
- Published by Wiley in Medical Physics
- Vol. 32 (2) , 376-379
A dual-energy technique for enhanced localization accuracy in intracavitary brachytherapy
The orthogonal imaging method is commonly used for source localization in brachytherapy. In some cases, however, difficulty is encountered in determining the dummy sources because of the presence of either contrast materials or bony structures. We here offer a novel method for source localization utilizing a dual-energy, radiographic technique. In this approach, two sets of orthogonal radiographic images (anterior-posterior and lateral views) are obtained using two different x-ray energies. Image processing (i.e., subtraction between two image sets) is carried out to enhance the source image. In a study performed using a laboratory developed pelvic phantom, it was demonstrated that the dual-energy method could significantly enhance the image quality of the dummy sources, and improve the achievable precision and relative accuracy in localization of source positions. When directly combined with digital imaging modalities, the dual-energy method can be a useful technique to improve the accuracy in brachytherapy source localization from planar radiographs.
- 14 January 2005
- Published by Wiley in Medical Physics
- Vol. 32 (2) , 376-379
A dual-energy technique for enhanced localization accuracy in intracavitary brachytherapy
The orthogonal imaging method is commonly used for source localization in brachytherapy. In some cases, however, difficulty is encountered in determining the dummy sources because of the presence of either contrast materials or bony structures. We here offer a novel method for source localization utilizing a dual-energy, radiographic technique. In this approach, two sets of orthogonal radiographic images (anterior-posterior and lateral views) are obtained using two different x-ray energies. Image processing (i.e., subtraction between two image sets) is carried out to enhance the source image. In a study performed using a laboratory developed pelvic phantom, it was demonstrated that the dual-energy method could significantly enhance the image quality of the dummy sources, and improve the achievable precision and relative accuracy in localization of source positions. When directly combined with digital imaging modalities, the dual-energy method can be a useful technique to improve the accuracy in brachytherapy source localization from planar radiographs.
- 1 August 2004
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 59 (5) , 1531-1539
An immobilization system for claustrophobic patients in head-and-neck intensity-modulated radiation therapy
- 1 August 2004
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 59 (5) , 1531-1539
An immobilization system for claustrophobic patients in head-and-neck intensity-modulated radiation therapy
- 6 February 2004
- Published by Wiley in Medical Physics
- Vol. 31 (3) , 500-506
Evaluation of intrafraction patient movement for CNS and head & neck IMRT
Intrafraction patient motion is much more likely in intensity-modulated radiation therapy (IMRT) than in conventional radiotherapy primarily due to longer beam delivery times in IMRT treatment. In this study, we evaluated the uncertainty of intrafraction patient displacement in CNS and head and neck IMRT patients. Immobilization is performed in three steps: (1) the patient is immobilized with thermoplastic facemask, (2) the patient displacement is monitored using a commercial stereotactic infrared IR camera (ExacTrac, BrainLab) during treatment, and (3) repositioning is carried out as needed. The displacement data were recorded during beam-on time for the entire treatment duration for 5 patients using the camera system. We used the concept of cumulative time versus patient position uncertainty, referred to as an uncertainty time histogram (UTH), to analyze the data. UTH is a plot of the accumulated time during which a patient stays within the corresponding movement uncertainty. The University of Florida immobilization procedure showed an effective immobilization capability for CNS and head and neck IMRT patients by keeping the patient displacement less than 1.5 mm for 95% of treatment time (1.43 mm for 1, and 1.02 mm for 1, and less than 1.0 mm for 3 patients). The maximum displacement was 2.0 mm.
- 6 February 2004
- Published by Wiley in Medical Physics
- Vol. 31 (3) , 500-506
Evaluation of intrafraction patient movement for CNS and head & neck IMRT
Intrafraction patient motion is much more likely in intensity-modulated radiation therapy (IMRT) than in conventional radiotherapy primarily due to longer beam delivery times in IMRT treatment. In this study, we evaluated the uncertainty of intrafraction patient displacement in CNS and head and neck IMRT patients. Immobilization is performed in three steps: (1) the patient is immobilized with thermoplastic facemask, (2) the patient displacement is monitored using a commercial stereotactic infrared IR camera (ExacTrac, BrainLab) during treatment, and (3) repositioning is carried out as needed. The displacement data were recorded during beam-on time for the entire treatment duration for 5 patients using the camera system. We used the concept of cumulative time versus patient position uncertainty, referred to as an uncertainty time histogram (UTH), to analyze the data. UTH is a plot of the accumulated time during which a patient stays within the corresponding movement uncertainty. The University of Florida immobilization procedure showed an effective immobilization capability for CNS and head and neck IMRT patients by keeping the patient displacement less than 1.5 mm for 95% of treatment time (1.43 mm for 1, and 1.02 mm for 1, and less than 1.0 mm for 3 patients). The maximum displacement was 2.0 mm.