UAUrsula Anderer

Ursula Anderer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ursula Anderer has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-dimensional scaffold-free fusion culture: the way to enhance chondrogenesis of in vitro propagated human articular chondrocytes

    by M. Lehmann, F. Martin, K. Mannigel, K. Kaltschmidt, U. Sack, U. Anderer

    Cartilage regeneration based on isolated and culture-expanded chondrocytes has been studied in various in vitro models, but the quality varies with respect to the morphology and the physiology of the synthesized tissues. The aim of our study was to promote in vitro chondrogenesis of human articular chondrocytes using a novel three-dimensional (3-D) cultivation system in combination with the chondrogenic differentiation factors transforming growth factor beta 2 (TGF-b2) and L-ascorbic acid. Articular chondrocytes isolated from six elderly patients were expanded in monolayer culture. A single-cell suspension of the dedifferentiated chondrocytes was then added to agar-coated dishes without using any scaffold material, in the presence, or absence of TGF-b2 and/or L-ascorbic acid. Three-dimensional cartilage-like constructs, called single spheroids, and microtissues consisting of several spheroids fused together, named as fusions, were formed. Generated tissues were mainly characterized using histological and immunohistochemical techniques. The morphology of the in vitro tissues shared some similarities to native hyaline cartilage in regard to differentiated S100-positive chondrocytes within a cartilaginous matrix, with strong collagen type II expression and increased synthesis of proteoglycans. Finally, our innovative scaffold-free fusion culture technique supported enhanced chondrogenesis of human articular chondrocytes in vitro. These 3-D hyaline cartilage-like microtissues will be useful for in vitro studies of cartilage differentiation and regeneration, enabling optimization of functional tissue engineering and possibly contributing to the development of new approaches to treat traumatic cartilage defects or osteoarthritis.


  • Open Access

    Automated interpretation of ANCA patterns - a new approach in the serology of ANCA-associated vasculitis

    by Ilka Knütter, Rico Hiemann, Therese Brumma, Thomas Büttner, Kai Großmann, Marco Cusini, Francesca Pregnolato, Maria Orietta Borghi, Ursula Anderer, Karsten Conrad, et al.

    Introduction: Indirect immunofluorescence (IIF) employing ethanol-fixed neutrophils (ethN) is still the method of choice for assessing antineutrophil cytoplasmic antibodies (ANCA) in ANCA-associated vasculitides (AAV). However, conventional fluorescence microscopy is subjective and prone to high variability. The objective of this study was to evaluate novel pattern recognition algorithms for the standardized automated interpretation of ANCA patterns. Methods: Seventy ANCA-positive samples (20 antimyeloperoxidase ANCA, 50 antiproteinase3 ANCA) and 100 controls from healthy individuals analyzed on ethN and formalin-fixed neutrophils (formN) by IIF were used as a 'training set' for the development of pattern recognition algorithms. Sera from 342 patients ('test set') with AAV and other systemic rheumatic and infectious diseases were tested for ANCA patterns using the novel pattern recognition algorithms and conventional fluorescence microscopy. Results: Interpretation software employing pattern recognition algorithms was developed enabling positive/negative discrimination and classification of cytoplasmic ANCA (C-ANCA) and perinuclear ANCA (P-ANCA). Comparison of visual reading of the 'test set' samples with automated interpretation revealed Cohen's kappa (κ) values of 0.955 on ethN and 0.929 on formN for positive/negative discrimination. Analysis of the 'test set' with regard to the discrimination between C-ANCA and P-ANCA patterns showed a high agreement for ethN (κ = 0.746) and formN (κ = 0.847). There was no significant difference between visual and automated interpretation regarding positive/negative discrimination on ethN and formN, as well as ANCA pattern recognition (P > 0.05, respectively). Conclusions: Pattern recognition algorithms can assist in the automated interpretation of ANCA IIF. Automated reading of ethN and formN IIF patterns demonstrated high consistency with visual ANCA assessment.


  • Automatic Analysis of Immunofluorescence Patterns of HEp‐2 Cells

    by Rico Hiemann, Nadja Hilger, Jörg Michel, Jörg Nitschke, Alexander Böhm, Ursula Anderer, Martin Weigert, Ulrich Sack

    The standard screening test for the recognition of autoimmune diseases is the proof of autoantibodies in serum of patients by indirect immunofluorescence (IIF) based on HEp-2 cells. Manual evaluation of this test is very subjective, slow, and there are no objective parameters as guidelines available. Interlaboratory tests showed occasionally large deviations in the test evaluation resulting in a high variance of results. The aim of this project is fast, objective, safe, and economical automatic analysis of HEp-2 IIF patterns. Images of IIF patterns were completely and automatically captured using an inverse motorized fluorescence microscope. Thereby, device-specific parameters were controlled automatically, too. For fast analysis of IIF patterns new algorithms of image processing were developed. Artifacts were recognized and excluded from analysis by the developed software. Analysis of more than 80,000 images clearly demonstrated full automatization and fast processing of IIF patterns. Additionally serum-specific fluorescence could be easily distinguished from background. Even very weak but positive patterns can be recognized and used for diagnosis. A detailed separation into different basic patterns is possible. Objective, fast, and disease-related economical analysis of HEp-2 immunofluorescence patterns is feasible. The implemented software algorithms allowed a mathematical way of describing IIF patterns and can therefore be a useful tool for the needed standardization process.