  • Diabetes mellitus increases the incidence of deep vein thrombosis after total knee arthroplasty

    by Zhongyuan Zhao, Shijun Wang, Weihua Ma, Gang Kong, Shudong Zhang, Yan Tang, Yuchi Zhao

    Introduction Many patients undergoing total knee arthroplasty (TKA) have diabetes mellitus, which may increase the risk of deep vein thrombosis (DVT) after TKA. We therefore assessed whether diabetes mellitus increased the incidence of DVT within 14 days after TKA. Materials and methods The incidence of DVT within 14 days of surgery was compared in diabetic and non-diabetic patients undergoing TKA in our hospital between June 2011 and February 2013. The relationships between diabetes mellitus and DVT were analyzed. Results Of the 358 enrolled patients, 70 (19.6 %) had diabetes and 288 (80.4 %) did not. DVT occurred within 14 days in 198 patients, 52 of 70 (74.3 %) in the diabetes group and 146 of 288 (50.7 %) in the non-diabetes group (p = 0.012). DVT of the contralateral leg was observed in 16 and 50 patients, respectively (p = 0.452). Logistic regression analysis showed that the risk of DVT was 2.71-fold higher in patients with than without diabetes mellitus (95 % CI 1.183–6.212, p = 0.018). There were no significant differences in age, gender, hypertension, BMI, duration of surgery, intra-operative blood loss, and duration of tourniquet between the two groups. Conclusions The incidence of DVT 14 days after TKA was significantly higher in patients with than without diabetes.


  • Open Access

    A comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up

    by ShiJun Wang, ShuDong Zhang, YuChi Zhao

    Study design: This is a retrospective study comparing polyethylene wear between ceramic ball heads and metal ball heads in total hip arthroplasty. Background: The ceramic-on-polyethylene bearing option has been introduced as an alternative to metal-on-polyethylene to minimize polyethylene wear debris and reduce subsequent osteolysis and aseptic loosening. However, the reported data were debatable. We designed this retrospective study to compare polyethylene wear between alumina ceramic ball heads and cobalt-chrome ball heads. Methods: Bilateral simultaneous primary total hip arthroplasty was performed in 22 patients between January 2002 and December 2002, with one side using metal-on-polyethylene bearing surface and the other side using alumina ceramic-on-polyethylene bearing surface. After 10 years of follow-up, the wear rate of polyethylene liner on both sides was measured using the Dorr method and compared. Results: The annual wear rate of the polyethylene liner was 0.133 mm with a standard deviation of 0.045 in the metal-on-polyethylene group and 0.056 mm with a standard deviation of 0.032 in the ceramic-on-polyethylene group. The wear rate per year was significantly lower in the ceramic-on-polyethylene group (p < 0.001). Conclusions: Although the implication is still controversial, our study showed that the use of ceramic head lowered the liner wear rate. Clinical relevance: Ceramic is harder and more resistant to scratching than cobalt-chrome. By increasing polyethylene liner survivorship and decreasing potential osteolytic response and aseptic loosening, ceramic head is a better alternative than cobalt-chrome head.