Xiaodong Zhong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Xiaodong Zhong has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Frederick Howard Epstein
Department of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA
4 shared publications - Brandon K. Fornwalt
Geisinger
2 shared publications Brian M. Dale
MR R&D Collaborations, Siemens Healthcare, Cary, NC, United States
2 shared publications- Bruce S. Spottiswoode
Division of Radiology, University of Stellenbosch, Cape Town, South Africa
2 shared publications - Christopher M. Haggerty
Department of Translational Data Science and Informatics, Geisinger, Danville, PA, USA
2 shared publications - Daniel A Auger
MRC/UCT Medical Imaging Research Unit, Department of Human Biology, University of Cape Town, Cape Town, South Africa
2 shared publications
Latest Publications
- Open Access
- 29 January 2019
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 32 (3) , 317-329
The feasibility of a novel limited field of view spiral cine DENSE sequence to assess myocardial strain in dilated cardiomyopathy
Objective Develop an accelerated cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance (CMR) sequence to enable clinically feasible myocardial strain evaluation in patients with dilated cardiomyopathy (DCM). Materials and methods A spiral cine DENSE sequence was modified by limiting the field of view in two dimensions using in-plane slice-selective pulses in the stimulated echo. This reduced breath hold duration from 20RR to 14RR intervals. Following phantom and pilot studies, the feasibility of the sequence to assess peak radial, circumferential, and longitudinal strain was tested in control subjects (n = 18) and then applied in DCM patients (n = 29). Results DENSE acquisition was possible in all participants. Elements of the data were not analysable in 1 control (6%) and 4 DCM r(14%) subjects due to off-resonance or susceptibility artefacts and low signal-to-noise ratio. Peak radial, circumferential, short-axis contour strain and longitudinal strain was reduced in DCM patients (p < 0.001 vs. controls) and strain measurements correlated with left ventricular ejection fraction (with circumferential strain r = − 0.79, p < 0.0001; with vertical long-axis strain r = − 0.76, p < 0.0001). All strain measurements had good inter-observer agreement (ICC > 0.80), except peak radial strain. Discussion We demonstrate the feasibility of CMR strain assessment in healthy controls and DCM patients using an accelerated cine DENSE technique. This may facilitate integration of strain assessment into routine CMR studies.
- 29 January 2019
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 32 (3) , 317-329
Open AccessThe feasibility of a novel limited field of view spiral cine DENSE sequence to assess myocardial strain in dilated cardiomyopathy
Objective Develop an accelerated cine displacement encoding with stimulated echoes (DENSE) cardiovascular magnetic resonance (CMR) sequence to enable clinically feasible myocardial strain evaluation in patients with dilated cardiomyopathy (DCM). Materials and methods A spiral cine DENSE sequence was modified by limiting the field of view in two dimensions using in-plane slice-selective pulses in the stimulated echo. This reduced breath hold duration from 20RR to 14RR intervals. Following phantom and pilot studies, the feasibility of the sequence to assess peak radial, circumferential, and longitudinal strain was tested in control subjects (n = 18) and then applied in DCM patients (n = 29). Results DENSE acquisition was possible in all participants. Elements of the data were not analysable in 1 control (6%) and 4 DCM r(14%) subjects due to off-resonance or susceptibility artefacts and low signal-to-noise ratio. Peak radial, circumferential, short-axis contour strain and longitudinal strain was reduced in DCM patients (p < 0.001 vs. controls) and strain measurements correlated with left ventricular ejection fraction (with circumferential strain r = − 0.79, p < 0.0001; with vertical long-axis strain r = − 0.76, p < 0.0001). All strain measurements had good inter-observer agreement (ICC > 0.80), except peak radial strain. Discussion We demonstrate the feasibility of CMR strain assessment in healthy controls and DCM patients using an accelerated cine DENSE technique. This may facilitate integration of strain assessment into routine CMR studies.
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 93-10
2D cine DENSE with low encoding frequencies accurately quantifies cardiac mechanics with improved image characteristics
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 93-10
Open Access2D cine DENSE with low encoding frequencies accurately quantifies cardiac mechanics with improved image characteristics
- Open Access
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 5
Validation of in vivo 2D displacements from spiral cine DENSE at 3T
- 1 January 2015
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 17 (1) , 5
Open AccessValidation of in vivo 2D displacements from spiral cine DENSE at 3T
- Open Access
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 8
Semi-automated left ventricular segmentation based on a guide point model approach for 3D cine DENSE cardiovascular magnetic resonance
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 8
Open AccessSemi-automated left ventricular segmentation based on a guide point model approach for 3D cine DENSE cardiovascular magnetic resonance
- Open Access
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 6
Feasibility of asymmetric stretch assessment in the ascending aortic wall with DENSE cardiovascular magnetic resonance
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 6
Open AccessFeasibility of asymmetric stretch assessment in the ascending aortic wall with DENSE cardiovascular magnetic resonance
- 9 December 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (5) , 1353-1365
Liver fat quantification using a multi‐step adaptive fitting approach with multi‐echo GRE imaging
Purpose: The purpose of this study was to develop a multi‐step adaptive fitting approach for liver proton density fat fraction (PDFF) and quantification, and to perform an initial validation on a broadly available hardware platform.Theory and Methods: The proposed method uses a multi‐echo three‐dimensional gradient echo acquisition, with initial guesses for the fat and water signal fractions based on a Dixon decomposition of two selected echoes. Based on magnitude signal equations with a multi‐peak fat spectral model, a multi‐step nonlinear fitting procedure is then performed to adaptively update the fat and water signal fractions and values. The proposed method was validated using numeric phantoms as ground truth, followed by preliminary clinical validation of PDFF calculations against spectroscopy in 30 patients.Results: The results of the proposed method agreed well with the ground truth of numerical phantoms, and were relatively insensitive to changes in field strength, field homogeneity, monopolar/bipolar readout, signal to noise ratio, and echo time selections. The in vivo patient study showed excellent consistency between the PDFF values measured with the proposed approach compared with spectroscopy.Conclusion: This multi‐step adaptive fitting approach performed well in both simulated and initial clinical evaluation, and shows potential in the quantification of hepatic steatosis. Magn Reson Med 72:1353–1365, 2014.
- 9 December 2013
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (5) , 1353-1365
Liver fat quantification using a multi‐step adaptive fitting approach with multi‐echo GRE imaging
Purpose: The purpose of this study was to develop a multi‐step adaptive fitting approach for liver proton density fat fraction (PDFF) and quantification, and to perform an initial validation on a broadly available hardware platform.Theory and Methods: The proposed method uses a multi‐echo three‐dimensional gradient echo acquisition, with initial guesses for the fat and water signal fractions based on a Dixon decomposition of two selected echoes. Based on magnitude signal equations with a multi‐peak fat spectral model, a multi‐step nonlinear fitting procedure is then performed to adaptively update the fat and water signal fractions and values. The proposed method was validated using numeric phantoms as ground truth, followed by preliminary clinical validation of PDFF calculations against spectroscopy in 30 patients.Results: The results of the proposed method agreed well with the ground truth of numerical phantoms, and were relatively insensitive to changes in field strength, field homogeneity, monopolar/bipolar readout, signal to noise ratio, and echo time selections. The in vivo patient study showed excellent consistency between the PDFF values measured with the proposed approach compared with spectroscopy.Conclusion: This multi‐step adaptive fitting approach performed well in both simulated and initial clinical evaluation, and shows potential in the quantification of hepatic steatosis. Magn Reson Med 72:1353–1365, 2014.
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 13-4
Mapping right ventricular myocardial mechanics using 3D cine DENSE cardiovascular magnetic resonance
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 13-4
Open AccessMapping right ventricular myocardial mechanics using 3D cine DENSE cardiovascular magnetic resonance
- Open Access
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 83
Comprehensive Cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 83
Open AccessComprehensive Cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE