Latest Publications

  • Open Access

    Self-calibration of microscopes based on 3D micro standards

    by Celina Hellmich, Rainer Köning, Matthias Schumann, Christoph Weichert

    A 2D self-calibration method based on orthogonal vector polynomials is presented and applied for the first time to measurements of a 3D micro standard by the PTB’s Nanometer Comparator (NMC) and a scanning electron microscope (SEM). The method separates the reproducible machine error field and the object errors by use of measurements in different orientations and locations of the object. The determination of the object displacements with the interferometer of the NMC provides a traceable scaling of the object. The 3D object used has markers on two different planes with a vertical distance of 1.2 μm, and its layout allows the rotation and shift of the object to be precisely identified. The maximum standard deviations of the marker positions in the X/Y direction were below 4 nm on the NMC. However, the residuals of the 2D equation system with a size of approx. 10 nm show a systematic difference between the markers on the upper and lower plane. This indicates that the machine error field of the NMC was not continuous in three dimensions. Therefore, the markers on the upper and lower planes were treated independently, thus the 2D error separation was performed separately for both planes. After the separate solutions with two different machine error fields for the two planes, the residuals of the equation systems did not contain significant systematic effects. Their standard deviation was below 2.2 nm for both planes. The traceable marker positions determined with the NMC were used to calibrate the SEM. Despite the larger depth of focus of the SEM, the vertical position of the markers also has an influence on the error field of the machine. The residuls of the equation system for both planes do not show systematic effects while their standard deviation was below 31 nm.

  • A single-beam 3DoF homodyne interferometer

    by Liang Yu, Gabor Molnar, Christian Andreas Werner, Christoph Weichert, Rainer Koening, Hans-Ulrich Danzebrink, Jiubin Tan, Jens Fluegge

    In this paper, a camera-based 3DoF homodyne interferometer is proposed to measure displacements and rotations with precision below nanometre/microradian level. The interferometer uses a single beam, has a simple and compact layout and is easy to adjust. A spatial interference pattern is introduced by a tilted reference mirror and recorded by a camera chip. The variation of the spacing and orientation of the fringes is correlated with the yaw and pitch angular rotation of the moving mirror, while the phase correlates with its displacement. The noise level and resolution of displacement and angle measurements were determined to be below 5 pm/√Hz and 5 nrad/√Hz above 1 Hz. Periodic nonlinearities of the system were mainly caused by multi-reflections between optical surfaces in the system. By choosing particular components and improving their adjustment, the displacement nonlinearity was reduced to be below 0.1 nm, and angle nonlinearities achieved sub-microradian level.


  • Investigation into the limitations of straightness interferometers using a multisensor-based error separation method

    by Christoph Weichert, Paul Köchert, Eugen Schötka, Jens Fluegge, Eberhard Manske

    The uncertainty of a straightness interferometer is independent of the component used to introduce the divergence angle between the two probing beams, and is limited by three main error sources, which are linked to each other: their resolution, the influence of refractive index gradients and the topography of the straightness reflector. To identify the configuration with minimal uncertainties under laboratory conditions, a fully fibre-coupled heterodyne interferometer was successively equipped with three different wedge prisms, resulting in three different divergence angles (4°, 8° and 20°). To separate the error sources an independent reference with a smaller reproducibility is needed. Therefore, the straightness measurement capability of the Nanometer Comparator, based on a multisensor error separation method, was improved to provide measurements with a reproducibility of 0.2 nm. The comparison results revealed that the influence of the refractive index gradients of air did not increase with interspaces between the probing beams of more than 11.3 mm. Therefore, over a movement range of 220 mm, the lowest uncertainty was achieved with the largest divergence angle. The dominant uncertainty contribution arose from the mirror topography, which was additionally determined with a Fizeau interferometer. The measured topography agreed within ±1.3 nm with the systematic deviations revealed in the straightness comparison, resulting in an uncertainty contribution of 2.6 nm for the straightness interferometer.


  • Das neue Antriebskonzept am Nanometerkomparator der PTB

    by Paul Köchert, Eberhard Manske, Rainer Köning, Christoph Weichert, Jens Flügge

    Zusammenfassung In diesem Beitrag wird ein neues Antriebskonzept des an der PTB für Längenmessungen bis zu 0,55 m betriebenen Vakuumkomparators beschrieben. Dessen Positioniersystem auf Basis eines Direktantriebs wurde um eine sekundäre Steuereinheit erweitert, um auf Grundlage von Rückkopplungsdaten seines Vakuum-Interferometers einen zusätzlichen elektromagnetischen Aktuator anzutreiben. Anhand von Messungen konnte mit diesem dezentralen Antriebskonzept ein Positionsrauschen (1 σ) von 0,2 nm bei einer Mitteilungszeit von 10 ms nachgewiesen werden.


  • Challenges in nanometrology: high precision measurement of position and size

    by Harald Bosse, Bernd Bodermann, Gaoliang Dai, Jens Flügge, Carl G. Frase, Hermann Groß, Wolfgang Häßler-Grohne, Paul Köchert, Rainer Köning, Frank Scholze, et al.

    Recent developments of the PTB in high precision position and size metrology as support for different nanotechnology applications are described. Measurement uncertainties of 1–2 nm for 1D-position of graduation lines on photomasks, or on line scales and incremental encoders of about 300 mm length have been achieved. The measurement of the size of nanoscale features represents additional challenges, because the location of opposite feature edges needs to be precisely determined. Different feature size or CD metrology techniques are applied at PTB, including a recent approach which uses transmission electron microscopy in the traceability chain of AFM CD measurements. The estimated uncertainty for CD measurements on high quality Si line structures is U 95% = 1.6 nm.


  • Ultra-präzise Lageregelung mittels interferometrischer Positionsdetektion und Tauchspulenantrieb

    by Paul Köchert, Jens Flügge, Rainer Köning, Christoph Weichert, Eberhard Manske

    Zusammenfassung: Dieser Beitrag beschreibt ein Mess- und Regelungssystem für einachsige Positionieranwendungen mit Stabilitäten im Sub-Nanometerbereich. Das Positioniersystem besteht aus einem luftgelagerten Linearschlitten, welcher mit einer Tauchspule gestellt, dessen Position laser-interferometrisch gemessen und unter Verwendung einer FPGA-gestützten Lageregelung mit hoher Bandbreite geregelt wird. Eine selbstentwickelte Auswerteelektronik zur Phasendemodulation wurde realisiert, um Positionen hochgenau zu detektieren und dem Regelungssystem mit geringer Verzögerung bereit zu stellen. Erste Messungen ergaben Positionsstabilitäten im Bereich von 0.1 nm.


  • Implementing registration measurements on photomasks at the Nanometer Comparator

    by Rainer Köning, Christoph Weichert, Bernd Przebierala, Jens Flügge, Wolfgang Haessler-Grohne, Harald Bosse