AKApril Khademi

April Khademi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


April Khademi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Anastasios Venetsanopoulos

    University of Toronto, Department of Electrical and Computer Engineering, Toronto, Ontario, M5S 3G4, CanadacRyerson University, Department of Electrical and Computer Engineering, Toronto, Ontario, M5B 2K3, Canada

    6 shared publications
  • Alan R. Moody

    University of Toronto, Department of Medical Imaging, Toronto, Ontario, M5T 1W7, CanadaeSunnybrook Research Institute, Department of Medical Imaging, Toronto, Ontario, M4N 3M5, Canada

    4 shared publications
  • Sridhar Krishnan

    Department of Electrical, Computer, and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON, Canada

    4 shared publications
  • A. R. Moody

    Department of Medical Imaging , Sunnybrook Health Sciences Center, Toronto, Canada

    1 shared publication

Latest Publications

  • Open Access

    Generalized method for partial volume estimation and tissue segmentation in cerebral magnetic resonance images

    by April Khademi, Anastasios Venetsanopoulos, Alan R. Moody

    An artifact found in magnetic resonance images (MRI) called partial volume averaging (PVA) has received much attention since accurate segmentation of cerebral anatomy and pathology is impeded by this artifact. Traditional neurological segmentation techniques rely on Gaussian mixture models to handle noise and PVA, or high-dimensional feature sets that exploit redundancy in multispectral datasets. Unfortunately, model-based techniques may not be optimal for images with non-Gaussian noise distributions and/or pathology, and multispectral techniques model probabilities instead of the partial volume (PV) fraction. For robust segmentation, a PV fraction estimation approach is developed for cerebral MRI that does not depend on predetermined intensity distribution models or multispectral scans. Instead, the PV fraction is estimated directly from each image using an adaptively defined global edge map constructed by exploiting a relationship between edge content and PVA. The final PVA map is used to segment anatomy and pathology with subvoxel accuracy. Validation on simulated and real, pathology-free T1 MRI (Gaussian noise), as well as pathological fluid attenuation inversion recovery MRI (non-Gaussian noise), demonstrate that the PV fraction is accurately estimated and the resultant segmentation is robust. Comparison to model-based methods further highlight the benefits of the current approach.


  • Robust White Matter Lesion Segmentation in FLAIR MRI

    by April Khademi, Anastasios Venetsanopoulos, A. R. Moody

    This paper discusses a white matter lesion (WML) segmentation scheme for fluid attenuation inversion recovery (FLAIR) MRI. The method computes the volume of lesions with subvoxel precision by accounting for the partial volume averaging (PVA) artifact. As WMLs are related to stroke and carotid disease, accurate volume measurements are most important. Manual volume computation is laborious, subjective, time consuming, and error prone. Automated methods are a nice alternative since they quantify WML volumes in an objective, efficient, and reliable manner. PVA is initially modeled with a localized edge strength measure since PVA resides in the boundaries between tissues. This map is computed in 3-D and is transformed to a global representation to increase robustness to noise. Significant edges correspond to PVA voxels, which are used to find the PVA fraction α (amount of each tissue present in mixture voxels). Results on simulated and real FLAIR images show high WML segmentation performance compared to ground truth (98.9% and 83% overlap, respectively), which outperforms other methods. Lesion load studies are included that automatically analyze WML volumes for each brain hemisphere separately. This technique does not require any distributional assumptions/parameters or training samples and is applied on a single MR modality, which is a major advantage compared to the traditional methods.


  • Open Access

    Shift-Invariant DWT for Medical Image Classification

    by April Khademi, Sridhar Krishnan, Anastasios Venetsanopoulos

  • Image Enhancement and Noise Suppression for FLAIR MRIs With White Matter Lesions

    by April Khademi, Anastasios Venetsanopoulos, Alan R. Moody

    This work presents an image reconstruction technique for noise suppression in FLAIR MRI with white matter lesions (WML). The technique utilizes a fuzzy edge estimate to initially localize edge information. Edge and intensity information are coupled through the conditional expectation operator, resulting in a robust and global description of the edge content in the image. As this global measure separates noise and useful edge information, a threshold is used to suppress the irrelevant details and integration is used to reconstruct the “noisefree” image. The threshold is automatically determined based on an objective function that minimizes noise (within class scatter) while maximizing contrast between the WML and brain tissue classes (between class variance). The result is an edge preserving smoothing filter, since the image is reconstructed based on the edge map. The proposed method was compared to the bilateral filter and was found to provide on average a 44.39% increase of noise attenuation in flat regions (smoothness) and a 34.14% increase in edge amplification (enhancement).


  • Edge-based partial volume averaging estimation for FLAIR MRI with white matter lesions

    by April Khademi, Anastasios Venetsanopoulos, Alan R. Moody

    Through the combination of intensity and fuzzy edge strength measures, a new partial volume averaging (PVA) quantification technique for FLAIR MRI with white matter lesions (WML) is developed. It is focused on an edge-based approach, which “probes” for PVA voxels via a global estimate for the change in the proportion of tissues α'. This estimate is refined according to a probabilistic threshold, and the result is decoded to find the proportion of tissues fraction α - the percentage of one tissue found in a mixture voxel. The results from several images are shown illustrating how the technique may be used to segment PVA and pure tissue classes. The result is a non-model based approach to the detection and quantification of PVA.


  • Shift-invariant discrete wavelet transform analysis for retinal image classification

    by April Khademi, Sridhar Krishnan

    This work involves retinal image classification and a novel analysis system was developed. From the compressed domain, the proposed scheme extracts textural features from wavelet coefficients, which describe the relative homogeneity of localized areas of the retinal images. Since the discrete wavelet transform (DWT) is shift-variant, a shift-invariant DWT was explored to ensure that a robust feature set was extracted. To combat the small database size, linear discriminant analysis classification was used with the leave one out method. 38 normal and 48 abnormal (exudates, large drusens, fine drusens, choroidal neovascularization, central vein and artery occlusion, histoplasmosis, arteriosclerotic retinopathy, hemi-central retinal vein occlusion and more) were used and a specificity of 79% and sensitivity of 85.4% were achieved (the average classification rate is 82.2%). The success of the system can be accounted to the highly robust feature set which included translation, scale and semi-rotational, features. Additionally, this technique is database independent since the features were specifically tuned to the pathologies of the human eye.


  • Multiresolution Analysis and Classification of Small Bowel Medical Images

    by April Khademi, Sridhar Krishnan

    This is the first reported work in the area of small bowel image classification and a novel analysis system was developed. Principles of human texture perception were used to design features which can discriminate between abnormal and normal images. The proposed method extracts statistical features from the wavelet domain, which describe the homogeneity of localized areas within the small bowel images. To ensure that robust features were extracted, a shift-invariant discrete wavelet transform (SIDWT) was explored. LDA classification was used with the leave one out method to improve classification under the small database scenario. A total of 75 abnormal and normal bowel images were used for experimentation resulting in high classification rates: 85% specificity and 85% sensitivity. The success of the system can be accounted to the discriminatory and robust feature set (translation, scale and semi-rotational invariant), which successfully classified various sizes and types of pathologies at multiple viewing angles.


  • Comparison of JPEG 2000 and Other Lossless Compression Schemes for Digital Mammograms

    by A. Khademi, S. Krishnan

    In this study, we propose JPEG 2000 as an algorithm for the compression of digital mammograms and the proposed work is the first real-time implementation of JPEG 2000 on a mammogram image database. Only the lossless compression mode of JPEG 2000 was examined to ensure that the mammogram is delivered without distortion. The performance of JPEG 2000 was compared against several other lossless coders: JPEG-LS, lossless-JPEG, adaptive Huffman, arithmetic with a zero order and a first order probability model and Lempel-Ziv Welch (EZW) with 12 and 15 bit dictionaries. Each compressor was supplied the identical set of 50 mammograms, each having a resolution of 8bits/pixel and dimensions of 1024times1024. Experimental results indicate JPEG 2000 and JPEG-LS provide comparable compression performance since their compression ratios differed by 0.72% and both compressors also superseded the results of the other coders. Although JPEG 2000 suffered from a slightly longer encoding and decoding delay than JPEG-ES (0.8 s on average), it is still preferred for mammogram images due to the wide variety of features that aid in reliable image transmission, provide an efficient mechanism for remote access to digital libraries and contribute to fast database access