Massoud A. Leesar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Massoud A. Leesar has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
Diaa Hakim
Division of Cardiology, Brigham & Women's Hospital/Harvard Medical School, Boston, MA, United States of America
6 shared publicationsFiras Al Solaiman
Division of Cardiovascular Disease, University of Alabama, Birmingham, Birmingham Veterans Affairs Medical Center, United States of America
6 shared publicationsArka Chatterjee
Division of Cardiovascular Disease, University of Alabama, Birmingham, Birmingham Veterans Affairs Medical Center, United States of America; Division of Cardiology, Banner-University Medical Center in Tucson, AZ, United States of America
4 shared publicationsOluseun Alli
Division of Cardiology, University of Alabama-Birmingham, Birmingham, Alabama
4 shared publicationsBrigitta C. Brott
Division of Cardiovascular Disease, University of Alabama, Birmingham, Birmingham Veterans Affairs Medical Center, United States of America
3 shared publications- Brigitta C. Brott
University of Alabama at Birmingham, Birmingham, Alabama, USA
3 shared publications
Latest Publications
- Open Access
- 28 May 2026
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 5 (7) , 105441
Intravascular Imaging Guidance for Percutaneous Coronary Intervention: Balancing Clinical Outcomes and Cost-Effectiveness
- 28 May 2026
- Published by Elsevier in Journal of the Society for Cardiovascular Angiography & Interventions
- Vol. 5 (7) , 105441
Open AccessIntravascular Imaging Guidance for Percutaneous Coronary Intervention: Balancing Clinical Outcomes and Cost-Effectiveness
- Open Access
- 4 December 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (1) , 102754
A Severely Calcified, Undilatable, Coronary Artery Stenosis
- 4 December 2024
- Published by Elsevier in JACC: Case Reports
- Vol. 30 (1) , 102754
Open AccessA Severely Calcified, Undilatable, Coronary Artery Stenosis
- Open Access
- 18 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (1) , ytad561
The first reported case of intravascular ultrasound-guided reverse overlapping stenting of a long calcified lesion using ultra-low contrast and metallic roadmaps: case report
Background: Percutaneous coronary intervention (PCI) of a long calcified coronary lesion in patients with chronic kidney disease (CKD) is challenging and can lead to stent under-expansion and contrast-induced acute kidney injury (CI-AKI). We described the first case of intravascular ultrasound (IVUS)-guided reverse overlapping stenting of long calcified left anterior descending (LAD) coronary lesion using ultra-low contrast and the metallic roadmaps to prevent CI-AKI after PCI. Case summary: A 77-year-old man with a history of hypertension, type 2 diabetes, and CKD was admitted with angina class 4 and ruled in for non-ST-elevation myocardial infarction. His ejection fraction was 40%. He was referred for cardiac catheterization and PCI. Coronary angiography showed a long calcified stenosis of the LAD. IVUS catheter was advanced at least 10 mm distal to the lesion or stent edge. IVUS images were obtained with automated pullback (1 mm/s) using a commercially available IVUS system with a 60-MHz mechanical transducer (Boston Scientific, Natick, Massachusetts). IVUS showed calcified plaque fractures after balloon angioplasty and intracoronary lithotripsy. The first stent was deployed proximally using the guidewire in the diagonal branch as a metallic roadmap, and the second stent was deployed distally overlapping at the distal edge of the first stent as a roadmap with no contrast injection. Percutaneous coronary intervention was completed successfully using only 12 mL contrast. Glomerular filtration rate remained stable after PCI. Glomerular filtration rate and ejection fraction improved at 12-month follow-up. Discussion: We described the first case of the reverse overlapping stenting technique guided by IVUS with no contrast in a patient with CKD and a long calcified LAD lesion. Conventionally, in long lesions, the first stent is deployed distally and the second stent proximally, which requires contrast injection for stent deployment. We demonstrated that the above technique resulted in preventing CI-AKI and improving creatinine as well as ejection fraction at follow-up.
- 18 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (1) , ytad561
Open AccessThe first reported case of intravascular ultrasound-guided reverse overlapping stenting of a long calcified lesion using ultra-low contrast and metallic roadmaps: case report
Background: Percutaneous coronary intervention (PCI) of a long calcified coronary lesion in patients with chronic kidney disease (CKD) is challenging and can lead to stent under-expansion and contrast-induced acute kidney injury (CI-AKI). We described the first case of intravascular ultrasound (IVUS)-guided reverse overlapping stenting of long calcified left anterior descending (LAD) coronary lesion using ultra-low contrast and the metallic roadmaps to prevent CI-AKI after PCI. Case summary: A 77-year-old man with a history of hypertension, type 2 diabetes, and CKD was admitted with angina class 4 and ruled in for non-ST-elevation myocardial infarction. His ejection fraction was 40%. He was referred for cardiac catheterization and PCI. Coronary angiography showed a long calcified stenosis of the LAD. IVUS catheter was advanced at least 10 mm distal to the lesion or stent edge. IVUS images were obtained with automated pullback (1 mm/s) using a commercially available IVUS system with a 60-MHz mechanical transducer (Boston Scientific, Natick, Massachusetts). IVUS showed calcified plaque fractures after balloon angioplasty and intracoronary lithotripsy. The first stent was deployed proximally using the guidewire in the diagonal branch as a metallic roadmap, and the second stent was deployed distally overlapping at the distal edge of the first stent as a roadmap with no contrast injection. Percutaneous coronary intervention was completed successfully using only 12 mL contrast. Glomerular filtration rate remained stable after PCI. Glomerular filtration rate and ejection fraction improved at 12-month follow-up. Discussion: We described the first case of the reverse overlapping stenting technique guided by IVUS with no contrast in a patient with CKD and a long calcified LAD lesion. Conventionally, in long lesions, the first stent is deployed distally and the second stent proximally, which requires contrast injection for stent deployment. We demonstrated that the above technique resulted in preventing CI-AKI and improving creatinine as well as ejection fraction at follow-up.
- Open Access
- 7 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 4 (1) , oead124
Cerebral blood flow and neurocognition in patients undergoing transcatheter aortic valve replacement for severe aortic stenosis
Aortic valve stenosis (AS) results in higher systolic pressure to overcome resistance from the stenotic valve, leading to heart failure and decline in cardiac output. There has been no assessment of cerebral blood flow (CBF) association with neurocognition in AS or the effects of valve replacement. The goal was to determine if AS is associated with altered cerebral haemodynamics and impaired neurocognition, and whether transcatheter aortic valve replacement (TAVR) improves haemodynamics and cognition. In 42 patients with planned TAVR, transcranial Doppler (TCD) assessed bilateral middle cerebral artery (MCA) mean flow velocities (MFVs); abnormality was Z-score. Impairment was Z-score was −0.22 SDs (range −1.99 to 1.08) below the normative mean. Among the 34 patients who returned after TAVR, the MFV was 41.59 cm/s (SD = 10.42), not different from baseline (P = 0.66, 2.28–3.67). Post-TAVR, average Z-scores were 0.17 SDs above the normative mean, not meeting the pre-specified threshold for a clinically significant 0.5 SD change. Among patients with severe AS, there was little impairment of MFV on TCD and no correlation with cognition. Transcatheter aortic valve replacement did not affect MFV or cognition. Assumptions about diminished CBF and improvement after TAVR were not supported. The relationship of cognition (Z-scores) to cerebral haemodynamics (mean flow velocity). Abnormality: ≥1.50 SD below normative means.
- 7 December 2023
- Published by Oxford University Press (OUP) in European Heart Journal Open
- Vol. 4 (1) , oead124
Open AccessCerebral blood flow and neurocognition in patients undergoing transcatheter aortic valve replacement for severe aortic stenosis
Aortic valve stenosis (AS) results in higher systolic pressure to overcome resistance from the stenotic valve, leading to heart failure and decline in cardiac output. There has been no assessment of cerebral blood flow (CBF) association with neurocognition in AS or the effects of valve replacement. The goal was to determine if AS is associated with altered cerebral haemodynamics and impaired neurocognition, and whether transcatheter aortic valve replacement (TAVR) improves haemodynamics and cognition. In 42 patients with planned TAVR, transcranial Doppler (TCD) assessed bilateral middle cerebral artery (MCA) mean flow velocities (MFVs); abnormality was Z-score. Impairment was Z-score was −0.22 SDs (range −1.99 to 1.08) below the normative mean. Among the 34 patients who returned after TAVR, the MFV was 41.59 cm/s (SD = 10.42), not different from baseline (P = 0.66, 2.28–3.67). Post-TAVR, average Z-scores were 0.17 SDs above the normative mean, not meeting the pre-specified threshold for a clinically significant 0.5 SD change. Among patients with severe AS, there was little impairment of MFV on TCD and no correlation with cognition. Transcatheter aortic valve replacement did not affect MFV or cognition. Assumptions about diminished CBF and improvement after TAVR were not supported. The relationship of cognition (Z-scores) to cerebral haemodynamics (mean flow velocity). Abnormality: ≥1.50 SD below normative means.
- Open Access
- 5 September 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (17) , e030572
Clinical and Vessel Characteristics Associated With Hard Outcomes After PCI and Their Combined Prognostic Implications
Background: Cardiac death or myocardial infarction still occurs in patients undergoing contemporary percutaneous coronary intervention (PCI). We aimed to identify adverse clinical and vessel characteristics related to hard outcomes after PCI and to investigate their individual and combined prognostic implications. Methods and Results: From an individual patient data meta‐analysis of 17 cohorts of patients who underwent post‐PCI fractional flow reserve measurement after drug‐eluting stent implantation, 2081 patients with available clinical and vessel characteristics were analyzed. The primary outcome was cardiac death or target‐vessel myocardial infarction at 2 years. The mean age of patients was 64.2±10.2 years, and the mean angiographic percent diameter stenosis was 63.9%±14.3%. Among 11 clinical and 8 vessel features, 4 adverse clinical characteristics (age ≥65 years, diabetes, chronic kidney disease, and left ventricular ejection fraction P P =0.03) and vice versa (area under the curve 0.68 versus 0.78; P =0.03). The cumulative event rate increased in the order of none, either, and both of adverse clinical characteristics ≥2 and adverse vessel characteristics ≥1 (0.3%, 2.4%, and 5.3%; P for trend <0.01). Conclusions: In patients undergoing drug‐eluting stent implantation, adverse clinical and vessel characteristics were associated with the risk of cardiac death or target‐vessel myocardial infarction. Because these characteristics showed independent and additive prognostic value, their integrative assessment can optimize post‐PCI risk stratification. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04684043. www.crd.york.ac.uk/prospero/ . Unique Identifier: CRD42021234748.
- 5 September 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (17) , e030572
Open AccessClinical and Vessel Characteristics Associated With Hard Outcomes After PCI and Their Combined Prognostic Implications
Background: Cardiac death or myocardial infarction still occurs in patients undergoing contemporary percutaneous coronary intervention (PCI). We aimed to identify adverse clinical and vessel characteristics related to hard outcomes after PCI and to investigate their individual and combined prognostic implications. Methods and Results: From an individual patient data meta‐analysis of 17 cohorts of patients who underwent post‐PCI fractional flow reserve measurement after drug‐eluting stent implantation, 2081 patients with available clinical and vessel characteristics were analyzed. The primary outcome was cardiac death or target‐vessel myocardial infarction at 2 years. The mean age of patients was 64.2±10.2 years, and the mean angiographic percent diameter stenosis was 63.9%±14.3%. Among 11 clinical and 8 vessel features, 4 adverse clinical characteristics (age ≥65 years, diabetes, chronic kidney disease, and left ventricular ejection fraction P P =0.03) and vice versa (area under the curve 0.68 versus 0.78; P =0.03). The cumulative event rate increased in the order of none, either, and both of adverse clinical characteristics ≥2 and adverse vessel characteristics ≥1 (0.3%, 2.4%, and 5.3%; P for trend <0.01). Conclusions: In patients undergoing drug‐eluting stent implantation, adverse clinical and vessel characteristics were associated with the risk of cardiac death or target‐vessel myocardial infarction. Because these characteristics showed independent and additive prognostic value, their integrative assessment can optimize post‐PCI risk stratification. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04684043. www.crd.york.ac.uk/prospero/ . Unique Identifier: CRD42021234748.
- Open Access
- 1 January 2023
- Published by OAE Publishing Inc. in The Journal of Cardiovascular Aging
- Vol. 3 (1) , 7
Thrombosis and myocardial infarction: the role of bioresorbable scaffolds
Coronary atherosclerosis is a leading cause of death as a result of coronary thrombosis and acute myocardial infarction. Drug-eluting stents (DES) have dramatically improved the treatment of coronary artery stenosis. However, stent thrombosis (ST) and in-stent-restenosis (ISR) have remained a vexing limitation of the DES. After DES implantation, despite taking dual antiplatelet (DAPT) therapy, very late ST results in myocardial infarction and death. This occurs regardless of the type of polymer or antiproliferative agent used in the contemporary DES. Such adverse events occur at a rate of approximately 2% to 3% per year after the first year, which have been attributed to strut fractures, loss of vessel compliance, and neoatherosclerosis. Bioresorbable scaffolds (BRS) have been introduced to overcome the above shortfalls and to a “leave nothing behind” approach. While BRS are novel and interesting, the initial experience with BRS was hampered by the increased rate of thrombosis compared with DES. Accordingly, in this review, we summarized underlying mechanisms leading to BRS failure and provided insights into optimizing BRS deployment with intravascular imaging. In addition, we outlined the perspectives of new generations of BRS with thinner struts and new designs as well as alternative materials to improve outcomes.
- 1 January 2023
- Published by OAE Publishing Inc. in The Journal of Cardiovascular Aging
- Vol. 3 (1) , 7
Open AccessThrombosis and myocardial infarction: the role of bioresorbable scaffolds
Coronary atherosclerosis is a leading cause of death as a result of coronary thrombosis and acute myocardial infarction. Drug-eluting stents (DES) have dramatically improved the treatment of coronary artery stenosis. However, stent thrombosis (ST) and in-stent-restenosis (ISR) have remained a vexing limitation of the DES. After DES implantation, despite taking dual antiplatelet (DAPT) therapy, very late ST results in myocardial infarction and death. This occurs regardless of the type of polymer or antiproliferative agent used in the contemporary DES. Such adverse events occur at a rate of approximately 2% to 3% per year after the first year, which have been attributed to strut fractures, loss of vessel compliance, and neoatherosclerosis. Bioresorbable scaffolds (BRS) have been introduced to overcome the above shortfalls and to a “leave nothing behind” approach. While BRS are novel and interesting, the initial experience with BRS was hampered by the increased rate of thrombosis compared with DES. Accordingly, in this review, we summarized underlying mechanisms leading to BRS failure and provided insights into optimizing BRS deployment with intravascular imaging. In addition, we outlined the perspectives of new generations of BRS with thinner struts and new designs as well as alternative materials to improve outcomes.
- 20 November 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (1) , 44-57
Multimodality imaging results of TAP versus novel modified TAP stenting in coronary bifurcation: From bench testing to first‐in‐man investigation
Objectives: We investigated the results of T and small protrusion (TAP) versus a novel modification of TAP (mTAP) stenting by multimodality imaging in bench testing and in patients with coronary bifurcation lesions (CBL).Background: TAP stenting is a suboptimal technique for bailout side branch (SB) stenting.Methods: In a bench model, optical coherence tomography (OCT), microscopic examinations (ME), and computational fluid dynamics (CFD) were performed after TAP and mTAP stenting. In 20 patients with CBL, 80 intravascular ultrasound (IVUS) examinations were performed during mTAP stenting in which the SB stent was pulled‐back to indent the inflated main vessel (MV) balloon and deployed while deflating it. For TAP stenting, the tip of the SB stent was positioned in the MV and deployed.Results: In bench testing, OCT showed neocarina length (NL) was shorter and minimum stent area (MSA) was larger after mTAP versus TAP stenting (2.84 ± 0.70 vs. 4.80 ± 020 mm; 6.75 ± 1.50 vs. 4.5 ± 2.2 mm2; respectively; p < 0.05). By ME, NL was shorter and shear rate trended lower after mTAP versus TAP stenting. In patients, IVUS showed MSA was larger after versus before mTAP stenting (6.32 ± 0.58 vs. 5.21 ± 0.56 mm2; p < 0.01); NL was 1.43 ± 0.22 mm with SB ostium coverage. The Seattle Angina questionnaire (SAQ) score was higher at 6 months versus baseline (85 ± 4.0 vs. 48 ± 6.0, respectively; p < 0.001).Conclusions: This multimodality imaging study showed, for the first time, mTAP stenting resulted in larger stent area and shorter neocarina than TAP stenting in bench testing. In patients with CBL, mTAP stenting led to larger stent area, short neocarina with complete SB ostium coverage, and improved the SAQ score at follow‐up.
- 20 November 2022
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 101 (1) , 44-57
Multimodality imaging results of TAP versus novel modified TAP stenting in coronary bifurcation: From bench testing to first‐in‐man investigation
Objectives: We investigated the results of T and small protrusion (TAP) versus a novel modification of TAP (mTAP) stenting by multimodality imaging in bench testing and in patients with coronary bifurcation lesions (CBL).Background: TAP stenting is a suboptimal technique for bailout side branch (SB) stenting.Methods: In a bench model, optical coherence tomography (OCT), microscopic examinations (ME), and computational fluid dynamics (CFD) were performed after TAP and mTAP stenting. In 20 patients with CBL, 80 intravascular ultrasound (IVUS) examinations were performed during mTAP stenting in which the SB stent was pulled‐back to indent the inflated main vessel (MV) balloon and deployed while deflating it. For TAP stenting, the tip of the SB stent was positioned in the MV and deployed.Results: In bench testing, OCT showed neocarina length (NL) was shorter and minimum stent area (MSA) was larger after mTAP versus TAP stenting (2.84 ± 0.70 vs. 4.80 ± 020 mm; 6.75 ± 1.50 vs. 4.5 ± 2.2 mm2; respectively; p < 0.05). By ME, NL was shorter and shear rate trended lower after mTAP versus TAP stenting. In patients, IVUS showed MSA was larger after versus before mTAP stenting (6.32 ± 0.58 vs. 5.21 ± 0.56 mm2; p < 0.01); NL was 1.43 ± 0.22 mm with SB ostium coverage. The Seattle Angina questionnaire (SAQ) score was higher at 6 months versus baseline (85 ± 4.0 vs. 48 ± 6.0, respectively; p < 0.001).Conclusions: This multimodality imaging study showed, for the first time, mTAP stenting resulted in larger stent area and shorter neocarina than TAP stenting in bench testing. In patients with CBL, mTAP stenting led to larger stent area, short neocarina with complete SB ostium coverage, and improved the SAQ score at follow‐up.
- Open Access
- 30 September 2022
- Published by Wolters Kluwer Health in Cardiology Discovery
- Vol. 2 (3) , 182-190
New Insights into Intravascular Imaging of Coronary Bifurcation Lesions and Left Main Stenosis: What Have We Accomplished?
Coronary bifurcation lesions (CBL) are one of the most challenging lesions to treat in interventional cardiology. Intravascular imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT) is paramount for the assessment of lesion characteristics and suboptimal stent results and to improve the outcome of percutaneous coronary intervention (PCI). After upgrading the use of IVUS and OCT by the American College of Cardiology/American Heart Association guidelines, their use has increased. Likewise, there has been significant improvement in image quality and the profile of system (ie, IVUS catheter size). The main indication for the use of IVUS includes: assessment of lesion characteristics, optimization of stent deployment, optimal stent expansion, exclusion of plaque burden >50%, and edge dissection. Intravascular imaging plays a significant role in the assessment and treatment of left main (LM) coronary artery stenosis and CBL. In particular, the use of intravascular imaging for alleviating mechanical issues during stenting and managing stent thrombosis has significantly increased. Overall, a compelling body of evidence has shown that the use of IVUS or OCT during PCI leads to optimal stenting results and mitigates the risk of adverse cardiac events. However, to date, the American College of Cardiology/American Heart Association Guidelines have assigned a Class IIb recommendation for IVUS or OCT, while the European Society of Cardiology Guidelines upgraded it to the Class IIa recommendation. This review summarized the role of IVUS and OCT for the assessment of stenosis and stent optimization in patients with CBL and LM stenosis. In addition, we discuss new insights into the role of IVUS- and OCT-guided stenting in patients with CBL and LM stenosis provided by the ongoing randomized trials.
- 30 September 2022
- Published by Wolters Kluwer Health in Cardiology Discovery
- Vol. 2 (3) , 182-190
Open AccessNew Insights into Intravascular Imaging of Coronary Bifurcation Lesions and Left Main Stenosis: What Have We Accomplished?
Coronary bifurcation lesions (CBL) are one of the most challenging lesions to treat in interventional cardiology. Intravascular imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT) is paramount for the assessment of lesion characteristics and suboptimal stent results and to improve the outcome of percutaneous coronary intervention (PCI). After upgrading the use of IVUS and OCT by the American College of Cardiology/American Heart Association guidelines, their use has increased. Likewise, there has been significant improvement in image quality and the profile of system (ie, IVUS catheter size). The main indication for the use of IVUS includes: assessment of lesion characteristics, optimization of stent deployment, optimal stent expansion, exclusion of plaque burden >50%, and edge dissection. Intravascular imaging plays a significant role in the assessment and treatment of left main (LM) coronary artery stenosis and CBL. In particular, the use of intravascular imaging for alleviating mechanical issues during stenting and managing stent thrombosis has significantly increased. Overall, a compelling body of evidence has shown that the use of IVUS or OCT during PCI leads to optimal stenting results and mitigates the risk of adverse cardiac events. However, to date, the American College of Cardiology/American Heart Association Guidelines have assigned a Class IIb recommendation for IVUS or OCT, while the European Society of Cardiology Guidelines upgraded it to the Class IIa recommendation. This review summarized the role of IVUS and OCT for the assessment of stenosis and stent optimization in patients with CBL and LM stenosis. In addition, we discuss new insights into the role of IVUS- and OCT-guided stenting in patients with CBL and LM stenosis provided by the ongoing randomized trials.