Cangli Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Cangli Liu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Bingqiang Luo
China Acad Engn Phys, Inst Fluid Phys, Mianyang 621999, Sichuan, Peoples R China
1 shared publication- Chao Lv
Institute of Fluid Physics, China Academy of Engineering Physics 2 , Mianyang 621900, China
1 shared publication - Chengjun Li
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
1 shared publication Chengwei Sun
China Acad Engn Phys, Inst Fluid Phys, Mianyang 621999, Sichuan, Peoples R China
1 shared publicationFengchao Wu
China Acad Engn Phys, Inst Fluid Phys, Mianyang 621999, Sichuan, Peoples R China
1 shared publicationFuli Tan
China Acad Engn Phys, Inst Fluid Phys, Mianyang 621999, Sichuan, Peoples R China
1 shared publication
Latest Publications
- Open Access
All-Fiber Pulse-Train Optical Frequency-Domain Interferometer for Dynamic Absolute Distance Measurements of Vibration
In this paper, we propose an all-fiber co-axial optical frequency-domain interferometer (OFDI) in a pulse-train mode with a sample rate of 9 kHz for measuring the vibrations in an internal structure without any contact. It was subjected to a range of 4.555 mm and had an accuracy level of 0.006 mm, as confirmed by a linear motion experiment. Due to the precise time synchronization for reducing the background light leakage and suppressing the dynamic fuzziness, the proposed OFDI could realize the dynamic absolute distance measurements of the vibration process under harmonic excitation with frequencies ranging from 200 Hz to 1800 Hz. The characteristic parameters of vibration could be analyzed using the acquired distance results. Furthermore, the OFDI system obtained the frequency conversion as the time under anharmonic periodic excitation with a sweeping rate of 3600 Hz/s. The measurement performance for the vibration velocity compared with the displacement interferometer system for any reflector (DISAR) was demonstrated in a harmonic excitation experiment. The proposed method expands the application of all-fiber OFDI technology from static to dynamic scenes.
Open AccessAll-Fiber Pulse-Train Optical Frequency-Domain Interferometer for Dynamic Absolute Distance Measurements of Vibration
In this paper, we propose an all-fiber co-axial optical frequency-domain interferometer (OFDI) in a pulse-train mode with a sample rate of 9 kHz for measuring the vibrations in an internal structure without any contact. It was subjected to a range of 4.555 mm and had an accuracy level of 0.006 mm, as confirmed by a linear motion experiment. Due to the precise time synchronization for reducing the background light leakage and suppressing the dynamic fuzziness, the proposed OFDI could realize the dynamic absolute distance measurements of the vibration process under harmonic excitation with frequencies ranging from 200 Hz to 1800 Hz. The characteristic parameters of vibration could be analyzed using the acquired distance results. Furthermore, the OFDI system obtained the frequency conversion as the time under anharmonic periodic excitation with a sweeping rate of 3600 Hz/s. The measurement performance for the vibration velocity compared with the displacement interferometer system for any reflector (DISAR) was demonstrated in a harmonic excitation experiment. The proposed method expands the application of all-fiber OFDI technology from static to dynamic scenes.
- 5 March 2022
- Published by Elsevier in Scripta Materialia
- Vol. 214
New explanation for the existence of B19′ phase in NiTi alloy from the perspective of twinning martensite
- 5 March 2022
- Published by Elsevier in Scripta Materialia
- Vol. 214
New explanation for the existence of B19′ phase in NiTi alloy from the perspective of twinning martensite
- Open Access
- 1 March 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (3) , 035250
Time-resolved imaging and spectroscopy diagnostic of aluminized RDX and pure RDX under nanosecond laser ablation
Laser ablation is a promising method for studying the chemical reactions and energy release in explosives. In this paper, we have investigated the combustion process of pure RDX and aluminized RDX through time-resolved observation of self-emitting imaging and emission spectroscopy under laser ablation. Since the recording devices can only conduct a one-time recording, we have performed a series of experiments with different time delays between the laser ablation and recording to realize time-resolved measurement. We also designed a sample plate with square array of circular holes to load the explosive powder, and every laser ablation can be acted on a complete fresh sample to ensure consistency of the sample status. The results show that, the nanosecond laser ablation causes no persistent combustion in pure RDX, the light intensity and spectral height show a monotone decline with a short duration; The aluminized RDX under laser ablation has typical secondary reaction characteristics, and exhibits better combusting performance in duration and intensity compared to the pure one. The spectral distribution with time indicates that the emission of AlO molecule is the main reason leading to secondary reaction and persistent combustion in aluminized RDX, which directly reveals that aluminum is the key role in promoting reaction and combustion.
- 1 March 2019
- Published by AIP Publishing in AIP Advances
- Vol. 9 (3) , 035250
Open AccessTime-resolved imaging and spectroscopy diagnostic of aluminized RDX and pure RDX under nanosecond laser ablation
Laser ablation is a promising method for studying the chemical reactions and energy release in explosives. In this paper, we have investigated the combustion process of pure RDX and aluminized RDX through time-resolved observation of self-emitting imaging and emission spectroscopy under laser ablation. Since the recording devices can only conduct a one-time recording, we have performed a series of experiments with different time delays between the laser ablation and recording to realize time-resolved measurement. We also designed a sample plate with square array of circular holes to load the explosive powder, and every laser ablation can be acted on a complete fresh sample to ensure consistency of the sample status. The results show that, the nanosecond laser ablation causes no persistent combustion in pure RDX, the light intensity and spectral height show a monotone decline with a short duration; The aluminized RDX under laser ablation has typical secondary reaction characteristics, and exhibits better combusting performance in duration and intensity compared to the pure one. The spectral distribution with time indicates that the emission of AlO molecule is the main reason leading to secondary reaction and persistent combustion in aluminized RDX, which directly reveals that aluminum is the key role in promoting reaction and combustion.
- 4 December 2015
- Published by Springer Nature in Science China Physics, Mechanics & Astronomy
- Vol. 58 (12) , 1-7
Energy convergence effect and jet phenomenon of shock-heavy spherical bubble interaction
- 4 December 2015
- Published by Springer Nature in Science China Physics, Mechanics & Astronomy
- Vol. 58 (12) , 1-7
Energy convergence effect and jet phenomenon of shock-heavy spherical bubble interaction
- 9 July 2014
- Published by ASME International in Journal of Fluids Engineering
- Vol. 136 (9) , 091205
On the Evolution of Double Shock-Accelerated Elliptic Gas Cylinders
The evolution of double elliptic heavy-gas (SF6) cylinders impacted by a planar shock wave is studied by high-speed camera diagnostics. The minor axes (b) of the elliptic cross sections are aligned perpendicular to the shock direction. While the cylinder dimensions are fixed, we adjust the center-to-center separation s between the cylinders. The resulting flow morphologies are visualized and the interaction between double cylinders is analyzed. When s/b = 4.0 or 3.0, the two elliptical cylinders roll up into two counter-rotating vortex pairs and their interaction is weak. When s/b decreases to 2.0 or 1.2, due to strong interaction of the two inner vortices, the inner structure completely disappears and the flow morphology evolves into one counter-vortex pair. Compared with the s/b = 2.0 case, larger amount of baroclinic vorticity is produced in the s/b = 1.2 case, and the morphology is similar to the single elliptic cylinder case, with a second vortex phenomenon occurring at later times. As s/b increases, the extent of cylinder-cylinder interaction becomes weaker, and the integral height of double elliptic cylinders grows while the length decreases.
- 9 July 2014
- Published by ASME International in Journal of Fluids Engineering
- Vol. 136 (9) , 091205
On the Evolution of Double Shock-Accelerated Elliptic Gas Cylinders
The evolution of double elliptic heavy-gas (SF6) cylinders impacted by a planar shock wave is studied by high-speed camera diagnostics. The minor axes (b) of the elliptic cross sections are aligned perpendicular to the shock direction. While the cylinder dimensions are fixed, we adjust the center-to-center separation s between the cylinders. The resulting flow morphologies are visualized and the interaction between double cylinders is analyzed. When s/b = 4.0 or 3.0, the two elliptical cylinders roll up into two counter-rotating vortex pairs and their interaction is weak. When s/b decreases to 2.0 or 1.2, due to strong interaction of the two inner vortices, the inner structure completely disappears and the flow morphology evolves into one counter-vortex pair. Compared with the s/b = 2.0 case, larger amount of baroclinic vorticity is produced in the s/b = 1.2 case, and the morphology is similar to the single elliptic cylinder case, with a second vortex phenomenon occurring at later times. As s/b increases, the extent of cylinder-cylinder interaction becomes weaker, and the integral height of double elliptic cylinders grows while the length decreases.