Jonathan W. Haft
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jonathan W. Haft has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Abbas Bitar
Division of Cardiovascular Medicine, University of Michigan Frankel Cardiovascular Center, Ann Arbor, Michigan
2 shared publications- Alvaro Rojas-Pena
Department of Surgery, Robert H. Bartlett ECLS Lab, University of Michigan, Ann Arbor, Michigan
2 shared publications Daniel E. Mazur
Michigan Critical Care Consultants, Inc, Ann Arbor, Michigan
2 shared publicationsDavid S. Demos
Department of Surgery, University of Michigan Health System, Extracorporeal Life Support Laboratory, Ann Arbor, Michigan
2 shared publications- Francis D. Pagani
Department of Cardiac Surgery, University of Michigan Medical School, Ann Arbor, Michigan
2 shared publications Gardner Yost
Cardiothoracic Surgery, University of Michigan, 1500 East Medical Center Drive 5144 CVC, Ann Arbor, MI 48109-5864, USA
2 shared publications
Latest Publications
- 18 August 2025
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 17 (3) , 327-335
Open Surgical Treatment of Acute and Chronic Pulmonary Embolism
- 18 August 2025
- Published by Elsevier in Cardiac Electrophysiology Clinics
- Vol. 17 (3) , 327-335
Open Surgical Treatment of Acute and Chronic Pulmonary Embolism
- Open Access
- 19 August 2024
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 10 (9) , e1701
Successful Resuscitation of Porcine Hearts After 12 and 24 h of Static Cold Storage With Normothermic Ex Situ Perfusion
Background.: Heart transplantation is always an emergency because the transplant needs to occur within 6 h after procurement to prevent primary graft dysfunction. Static cold storage (SCS) is the gold-standard preservation method. This study describes the outcomes of hearts preserved after prolonged SCS (12 and 24 h); those are then resuscitated with a novel normothermic ex situ heart perfusion (NEHP) system. Methods.: Anesthetized piglets (n = 10) were used as heart donors. Hearts were procured and stored at 5 °C CoStorSol following standard SCS protocols. Two groups were studied: SCS-12 h and SCS-24 h. After SCS, 8 h of NEHP (37 °C blood-based perfusate) was performed at 0.7–1.0 mL/min/g of cardiac tissue. NEHP parameters were monitored continuously. Results were corroborated with 3 additional hearts transplanted orthotopically in healthy recipients (n = 3) after SCS (24 h) + NEHP (5 h). Recipients were observed for 90 min after weaning off cardiopulmonary bypass support. Results.: All hearts (after 12 and 24 h of SCS) regained normal function and metabolism within 10 min and retained it throughout 8 h of NEHP. No differences were observed in NEHP parameters and histopathology between groups. Three hearts were successfully transplanted after a total ~30 h of preservation (24 h of SCS + 5 h of NEHP + 1 h of second cold ischemia time). The 3 recipients were weaned off cardiopulmonary bypass with mild vasopressor support. Conclusions.: NEHP has the potential to routinely resuscitate porcine hearts that have undergone SCS for up to 24 h, restoring them to viable function. By objectively assessing heart function before transplant, NEHP may enhance the success rate of transplants. If these resuscitated hearts can be successfully transplanted, it would support the effectiveness of NEHP in ensuring heart viability.
- 19 August 2024
- Published by Wolters Kluwer Health in Transplantation Direct
- Vol. 10 (9) , e1701
Open AccessSuccessful Resuscitation of Porcine Hearts After 12 and 24 h of Static Cold Storage With Normothermic Ex Situ Perfusion
Background.: Heart transplantation is always an emergency because the transplant needs to occur within 6 h after procurement to prevent primary graft dysfunction. Static cold storage (SCS) is the gold-standard preservation method. This study describes the outcomes of hearts preserved after prolonged SCS (12 and 24 h); those are then resuscitated with a novel normothermic ex situ heart perfusion (NEHP) system. Methods.: Anesthetized piglets (n = 10) were used as heart donors. Hearts were procured and stored at 5 °C CoStorSol following standard SCS protocols. Two groups were studied: SCS-12 h and SCS-24 h. After SCS, 8 h of NEHP (37 °C blood-based perfusate) was performed at 0.7–1.0 mL/min/g of cardiac tissue. NEHP parameters were monitored continuously. Results were corroborated with 3 additional hearts transplanted orthotopically in healthy recipients (n = 3) after SCS (24 h) + NEHP (5 h). Recipients were observed for 90 min after weaning off cardiopulmonary bypass support. Results.: All hearts (after 12 and 24 h of SCS) regained normal function and metabolism within 10 min and retained it throughout 8 h of NEHP. No differences were observed in NEHP parameters and histopathology between groups. Three hearts were successfully transplanted after a total ~30 h of preservation (24 h of SCS + 5 h of NEHP + 1 h of second cold ischemia time). The 3 recipients were weaned off cardiopulmonary bypass with mild vasopressor support. Conclusions.: NEHP has the potential to routinely resuscitate porcine hearts that have undergone SCS for up to 24 h, restoring them to viable function. By objectively assessing heart function before transplant, NEHP may enhance the success rate of transplants. If these resuscitated hearts can be successfully transplanted, it would support the effectiveness of NEHP in ensuring heart viability.
- 11 March 2024
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (9) , 767-772
Mechanical Analysis of a Novel Sternal Closure System in Static Tensile Loading
The most common means of sternal closure after sternotomy is stainless steel wire cerclage. These wires, while inexpensive and simple in design, are known to be associated with low strength and sternal dehiscence. In this biomechanical analysis, we compare single sternal wires, double sternal wires, and a novel sternal closure device we have designed to mitigate sternal dehiscence. The device uses polymer grommets at the sternal interfaces to distribute load over a large surface area of bone. Samples of each closure device were installed in a bone model and distracted at a rate of 10 mm/min while tensile forces were continuously measured and compared. Single wires generated the lowest stiffness and strength values, followed by the double wires. The novel device demonstrated significantly higher stiffness and strength at all displacements compared with the single and double wires. Clinical use of this device may result in meaningful reduction in complications associated with the use of standard sternal wires such as sternal separation and fracture.
- 11 March 2024
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 70 (9) , 767-772
Mechanical Analysis of a Novel Sternal Closure System in Static Tensile Loading
The most common means of sternal closure after sternotomy is stainless steel wire cerclage. These wires, while inexpensive and simple in design, are known to be associated with low strength and sternal dehiscence. In this biomechanical analysis, we compare single sternal wires, double sternal wires, and a novel sternal closure device we have designed to mitigate sternal dehiscence. The device uses polymer grommets at the sternal interfaces to distribute load over a large surface area of bone. Samples of each closure device were installed in a bone model and distracted at a rate of 10 mm/min while tensile forces were continuously measured and compared. Single wires generated the lowest stiffness and strength values, followed by the double wires. The novel device demonstrated significantly higher stiffness and strength at all displacements compared with the single and double wires. Clinical use of this device may result in meaningful reduction in complications associated with the use of standard sternal wires such as sternal separation and fracture.
- 23 April 2023
- Published by Elsevier in Interventional Cardiology Clinics
- Vol. 12 (3) , 339-347
Open Surgical Treatment of Acute and Chronic Pulmonary Embolism
- 23 April 2023
- Published by Elsevier in Interventional Cardiology Clinics
- Vol. 12 (3) , 339-347
Open Surgical Treatment of Acute and Chronic Pulmonary Embolism
- 22 May 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (5) , e87-e89
Late HeartMate 3 Thrombosis
There are few reports of HeartMate 3 pump thrombosis, with existing reports relating to outflow occlusion or early perioperative thrombosis. We present a case of late pump thrombosis requiring pump exchange.
- 22 May 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (5) , e87-e89
Late HeartMate 3 Thrombosis
There are few reports of HeartMate 3 pump thrombosis, with existing reports relating to outflow occlusion or early perioperative thrombosis. We present a case of late pump thrombosis requiring pump exchange.
- Open Access
- 25 April 2019
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 14 (1) , 1-8
Right ventricular failure following left ventricular assist device implantation is associated with a preoperative pro-inflammatory response
Systemic inflammation during implant of a durable left ventricular assist device (LVAD) may contribute to adverse outcomes. We investigated the association of the preoperative inflammatory markers with subsequent right ventricular failure (RVF). Prospective data was collected on 489 patients from 2003 through 2017 who underwent implantation of a durable LVAD. Uni- and multivariable correlation with leukocytosis was determined using linear and binary logistic regression. The population was also separated into low (< 10.5 K/ul, n = 362) and high (> 10.5 K/ul, n = 127) white blood cell count (WBC) groups. Mantel-Cox statistics was used to analyze survival data. Postop RVF was associated with a higher preop WBC (11.3 + 5.7 vs 8.7 + 3.1) and C-reactive protein (CRP, 5.6 + 4.4 vs 3.3 + 4.7) levels. Multivariable analysis identified an independent association between increased WBC preoperatively with increased lactate dehydrogenase (LDH, P < 0.001), heart rate (P < 0.001), CRP (P = 0.006), creatinine (P = 0.048), and INR (P = 0.049). The high WBC group was more likely to be on preoperative temporary circulatory support (17.3% vs 6.4%, P < 0.001) with a trend towards greater use of an intra-aortic balloon pump (55.9% vs 47.2%, P = 0.093). The high WBC group had poorer mid-term survival (P = 0.042). Postop RVF is associated with a preoperative pro-inflammatory environment. This may be secondary to the increased systemic stress of decompensated heart failure. Systemic inflammation in the decompensated heart failure may contribute to RVF after LVAD implant.
- 25 April 2019
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 14 (1) , 1-8
Open AccessRight ventricular failure following left ventricular assist device implantation is associated with a preoperative pro-inflammatory response
Systemic inflammation during implant of a durable left ventricular assist device (LVAD) may contribute to adverse outcomes. We investigated the association of the preoperative inflammatory markers with subsequent right ventricular failure (RVF). Prospective data was collected on 489 patients from 2003 through 2017 who underwent implantation of a durable LVAD. Uni- and multivariable correlation with leukocytosis was determined using linear and binary logistic regression. The population was also separated into low (< 10.5 K/ul, n = 362) and high (> 10.5 K/ul, n = 127) white blood cell count (WBC) groups. Mantel-Cox statistics was used to analyze survival data. Postop RVF was associated with a higher preop WBC (11.3 + 5.7 vs 8.7 + 3.1) and C-reactive protein (CRP, 5.6 + 4.4 vs 3.3 + 4.7) levels. Multivariable analysis identified an independent association between increased WBC preoperatively with increased lactate dehydrogenase (LDH, P < 0.001), heart rate (P < 0.001), CRP (P = 0.006), creatinine (P = 0.048), and INR (P = 0.049). The high WBC group was more likely to be on preoperative temporary circulatory support (17.3% vs 6.4%, P < 0.001) with a trend towards greater use of an intra-aortic balloon pump (55.9% vs 47.2%, P = 0.093). The high WBC group had poorer mid-term survival (P = 0.042). Postop RVF is associated with a preoperative pro-inflammatory environment. This may be secondary to the increased systemic stress of decompensated heart failure. Systemic inflammation in the decompensated heart failure may contribute to RVF after LVAD implant.
- 1 June 2015
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 99 (6) , 2256
Reply
- 1 July 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 98 (1) , 97-102
In Vivo Testing of a Novel Blood Pump for Short-Term Extracorporeal Life Support
- 1 July 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 98 (1) , 97-102
In Vivo Testing of a Novel Blood Pump for Short-Term Extracorporeal Life Support
- 1 July 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 98 (1) , 84-90
Outcomes After Transfer to a Tertiary Center for Postcardiotomy Cardiopulmonary Failure
- 1 July 2014
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 98 (1) , 84-90
Outcomes After Transfer to a Tertiary Center for Postcardiotomy Cardiopulmonary Failure