David Burling
Research Subjects
David Burling has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Steve Halligan
Centre for Medical Imaging, University College London, London, United Kingdom
6 shared publications - Stuart Andrew Taylor
Centre for Medical Imaging, University College London , London
6 shared publications Andrew Slater
Department of Imaging, John Radcliffe Hospital, Headington Way, Oxford, UK
2 shared publicationsBrian P. Saunders
2 shared publications- Darren Boone
Post Graduate Medical Institute, Anglia Ruskin University, Chelmsford, UK
2 shared publications James E. East
2 shared publications
Latest Publications
- 1 April 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (1) , 133-140
CT Colonography and Computer-aided Detection: Effect of False-Positive Results on Reader Specificity and Reading Efficiency in a Low-Prevalence Screening Population
To retrospectively evaluate the effect of increasing numbers of computer-aided detection (CAD)-generated false-positive (FP) marks on reader specificity and reporting times by using computed tomographic (CT) colonography in a low-prevalence screening population. Ethics committee approval and informed consent were obtained for this HIPAA-compliant study. Four readers each read 48 data sets (26 men, 22 women; mean age, 57 years) from a screening population (three containing polyps) without CAD application, followed by review of the CAD output and recorded findings and diagnostic confidence. The 45 data sets that were designated as normal were chosen such that 22 generated 15 or fewer FP CAD marks and 23 generated more than 15 FP CAD marks. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated with and without CAD. The relationships between the number of CAD FP marks and reader confidence, reporting times, and correct data set classification were analyzed by using linear and logistic regression. Across all readers, CAD resulted in four additional FP detections. Overall reader sensitivity and specificity (6-mm polyp threshold) before and after CAD application were 0.75 (95% confidence interval [CI]: 0.43, 0.95) versus 0.83 (95% CI: 0.52, 0.98) and 0.96 (95% CI: 0.91, 0.98) versus 0.93 (95% CI: 0.88, 0.96), respectively. The area under the ROC curve increased from 0.57 (95% CI: 0.34, 0.80) to 0.61 (95% CI: 0.42, 0.80). There was no correlation between an increasing number of CAD FP marks and reader confidence (P = .71) or correct study classification (P = .23), but there was a positive correlation with CAD-assisted reading times (0.06 [95% CI: 0.02, 0.10], P = .002). Increasing numbers of CAD FP marks did not adversely influence correct reader study classification or diagnostic confidence, although reporting times did increase.
- 1 April 2008
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 247 (1) , 133-140
CT Colonography and Computer-aided Detection: Effect of False-Positive Results on Reader Specificity and Reading Efficiency in a Low-Prevalence Screening Population
To retrospectively evaluate the effect of increasing numbers of computer-aided detection (CAD)-generated false-positive (FP) marks on reader specificity and reporting times by using computed tomographic (CT) colonography in a low-prevalence screening population. Ethics committee approval and informed consent were obtained for this HIPAA-compliant study. Four readers each read 48 data sets (26 men, 22 women; mean age, 57 years) from a screening population (three containing polyps) without CAD application, followed by review of the CAD output and recorded findings and diagnostic confidence. The 45 data sets that were designated as normal were chosen such that 22 generated 15 or fewer FP CAD marks and 23 generated more than 15 FP CAD marks. Sensitivity, specificity, and receiver operating characteristic (ROC) curves were calculated with and without CAD. The relationships between the number of CAD FP marks and reader confidence, reporting times, and correct data set classification were analyzed by using linear and logistic regression. Across all readers, CAD resulted in four additional FP detections. Overall reader sensitivity and specificity (6-mm polyp threshold) before and after CAD application were 0.75 (95% confidence interval [CI]: 0.43, 0.95) versus 0.83 (95% CI: 0.52, 0.98) and 0.96 (95% CI: 0.91, 0.98) versus 0.93 (95% CI: 0.88, 0.96), respectively. The area under the ROC curve increased from 0.57 (95% CI: 0.34, 0.80) to 0.61 (95% CI: 0.42, 0.80). There was no correlation between an increasing number of CAD FP marks and reader confidence (P = .71) or correct study classification (P = .23), but there was a positive correlation with CAD-assisted reading times (0.06 [95% CI: 0.02, 0.10], P = .002). Increasing numbers of CAD FP marks did not adversely influence correct reader study classification or diagnostic confidence, although reporting times did increase.
- 30 April 2007
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 65 (5) , AB268
Effect of Antispasmodic On Colonic Surface Area Visualisation At CT Simulated Optical Colonoscopy
- 30 April 2007
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 65 (5) , AB268
Effect of Antispasmodic On Colonic Surface Area Visualisation At CT Simulated Optical Colonoscopy
- 30 April 2007
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 65 (5) , AB94
Surface Visualisation At CT Colonography Simulated Optical Colonoscopy: Wide Angle Colonoscopy and Retrograde Viewing Auxiliary Imaging Devices
- 30 April 2007
- Published by Elsevier in Gastrointestinal Endoscopy
- Vol. 65 (5) , AB94
Surface Visualisation At CT Colonography Simulated Optical Colonoscopy: Wide Angle Colonoscopy and Retrograde Viewing Auxiliary Imaging Devices
- 31 July 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (7) , 850-859
CT Colonography: Effect of Colonic Distension on Polyp Measurement Accuracy and Agreement—In Vitro Study
- 31 July 2006
- Published by Elsevier in Academic Radiology
- Vol. 13 (7) , 850-859
CT Colonography: Effect of Colonic Distension on Polyp Measurement Accuracy and Agreement—In Vitro Study
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 759-767
Polyp Detection with CT Colonography: Primary 3D Endoluminal Analysis versus Primary 2D Transverse Analysis with Computer-assisted Reader Software
To retrospectively compare primary three-dimensional (3D) endoluminal analysis with primary two-dimensional (2D) transverse analysis supplemented by computer-assisted reader (CAR) software for computed tomographic (CT) polyp detection and reader reporting times. Ethical permission and patient consent were obtained from all donor institutions for use of CT colonography data sets. Twenty CT colonography data sets from 14 men (median age, 61 years; age range, 52-78 years) with 48 endoscopically proved polyps were selected. Polyp coordinates were documented in consensus by three unblinded radiologists to create a reference standard. Two radiologists read the data sets, which were randomized between primary 3D endoluminal views with 2D problem solving and 2D views supplemented by CAR software. Reading times and diagnostic confidence were documented. The CAR software highlighted possible polyps by superimposing circles on the 2D transverse images. Data sets were reread after 1 month by using the opposing analysis method. Detection rates were compared by using the McNemar test. Reporting times and diagnostic confidence were compared by using the paired t test and Mann-Whitney U test, respectively. Mean sensitivity values for polyps measuring 1-5, 6-9, and 10 mm or larger were 14%, 53%, and 83%, respectively, for 2D CAR analysis and 16%, 53%, and 67%, respectively, for primary 3D analysis. Overall sensitivity values were 41% for 2D CAR analysis and 39% for primary 3D analysis (P=.77). Reader 1 detected more polyps than reader 2, particularly when using the 3D fly-through method (P=.002). Mean reading times were significantly longer with the 3D method (P=.001). Mean false-positive findings were 1.5 for 2D analysis and 5.5 for 3D analysis. Reader confidence was not significantly different between analysis methods (P=.42). Two-dimensional CAR analysis is quicker and at least matches the sensitivity of primary 3D endoluminal analysis, with fewer false-positive findings.
- 1 June 2006
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 239 (3) , 759-767
Polyp Detection with CT Colonography: Primary 3D Endoluminal Analysis versus Primary 2D Transverse Analysis with Computer-assisted Reader Software
To retrospectively compare primary three-dimensional (3D) endoluminal analysis with primary two-dimensional (2D) transverse analysis supplemented by computer-assisted reader (CAR) software for computed tomographic (CT) polyp detection and reader reporting times. Ethical permission and patient consent were obtained from all donor institutions for use of CT colonography data sets. Twenty CT colonography data sets from 14 men (median age, 61 years; age range, 52-78 years) with 48 endoscopically proved polyps were selected. Polyp coordinates were documented in consensus by three unblinded radiologists to create a reference standard. Two radiologists read the data sets, which were randomized between primary 3D endoluminal views with 2D problem solving and 2D views supplemented by CAR software. Reading times and diagnostic confidence were documented. The CAR software highlighted possible polyps by superimposing circles on the 2D transverse images. Data sets were reread after 1 month by using the opposing analysis method. Detection rates were compared by using the McNemar test. Reporting times and diagnostic confidence were compared by using the paired t test and Mann-Whitney U test, respectively. Mean sensitivity values for polyps measuring 1-5, 6-9, and 10 mm or larger were 14%, 53%, and 83%, respectively, for 2D CAR analysis and 16%, 53%, and 67%, respectively, for primary 3D analysis. Overall sensitivity values were 41% for 2D CAR analysis and 39% for primary 3D analysis (P=.77). Reader 1 detected more polyps than reader 2, particularly when using the 3D fly-through method (P=.002). Mean reading times were significantly longer with the 3D method (P=.001). Mean false-positive findings were 1.5 for 2D analysis and 5.5 for 3D analysis. Reader confidence was not significantly different between analysis methods (P=.42). Two-dimensional CAR analysis is quicker and at least matches the sensitivity of primary 3D endoluminal analysis, with fewer false-positive findings.
- 1 August 2004
- Published by Taylor & Francis in Expert Review of Anticancer Therapy
- Vol. 4 (4) , 615-625
Computerized tomography colonography
First introduced a decade ago, computerized tomography (CT) colonography (virtual colonoscopy) is emerging as an important radiologic investigation for colorectal neoplasia, with diagnostic performance likely exceeding barium enema and comparable with optical colonoscopy. Employing state-of-the-art multislice technology, CT colonography allows a complete examination of the colon and surrounding organs in less than 30 seconds. This article reviews current techniques, indications, comparison with existing technologies, and diagnostic performance. Although already widely disseminated, important future developments, such as prepless bowel cleansing (laxative free) and computer-aided diagnosis, may establish CT colonography as the preferred first-line, whole-colon investigation.
- 1 August 2004
- Published by Taylor & Francis in Expert Review of Anticancer Therapy
- Vol. 4 (4) , 615-625
Computerized tomography colonography
First introduced a decade ago, computerized tomography (CT) colonography (virtual colonoscopy) is emerging as an important radiologic investigation for colorectal neoplasia, with diagnostic performance likely exceeding barium enema and comparable with optical colonoscopy. Employing state-of-the-art multislice technology, CT colonography allows a complete examination of the colon and surrounding organs in less than 30 seconds. This article reviews current techniques, indications, comparison with existing technologies, and diagnostic performance. Although already widely disseminated, important future developments, such as prepless bowel cleansing (laxative free) and computer-aided diagnosis, may establish CT colonography as the preferred first-line, whole-colon investigation.