DCDario Caldiroli

Dario Caldiroli

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dario Caldiroli has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 16 December 2015
      • Vol. 82  (1) , 12-4

    Prediction of difficult intubation with direct laryngoscopy winded up in quicksand: how can we get out of it?

    by Dario Caldiroli, Paolo Cortellazzi

    • 24 May 2011
      • Vol. 77  (10) , 1011-7

    A new difficult airway management algorithm based upon the El Ganzouri Risk Index and GlideScope® videolaryngoscope. A new look for intubation?

    by D Caldiroli, P Cortellazzi

    An El Ganzouri risk index test (EGRI) score of seven and the ability to achieve difficult laryngeal exposure with the GlideScope® may represent a highly predictive decisional threshold. Hence, we hypothesized that a new difficult airways algorithm that is EGRI- and GlideScope®-based may enable tracheal intubation in every patient. Thirteen staff practitioners trained in videolaryngoscopic intubation followed the algorithm from 2008 through 2010. Elective and emergency neurosurgical patients assessed as having an EGRI score of seven and higher underwent flexible fiberoptic bronchoscopy (FFB) intubation while conscious. Those with a score of six and lower were intubated with the GlideScope®, excluding patients with morbid obesity or pharyngo-laryngeal or neck tumors. A decision to perform alternative procedures, difficult laryngeal exposure [Cormack and Lehane (CL) grades III-IV], difficult ventilation and failure to intubate were recorded. The decisional rule was applied in 6,276 patients and resulted in six FFB intubations in conscious patients. The overall incidence of CL grade III-IV views was 0.2%. Difficult videolaryngoscopy was found in 14 patients (0.14%) with a score of 6 and lower. Post-hoc examinations of FFB intubations revealed five difficult laryngeal exposures. The positive predictive value was 85.7%, while the negative predictive value was 99.9%. The incidence of difficult ventilation and difficult laryngeal exposure was 0.03%. Two patients with neck tumors were assigned to alternative procedures. Adherence to the decisional process of the algorithm and to GlideScope® videolaryngoscopy achieved successful tracheal intubation in our cohort of patients.


  • Early experience with remote pressure sensor respiratory plethysmography monitoring sedation in the MR scanner

    by D. Caldiroli, L. Minati

    Background and objective: The importance of monitoring the breathing pattern during sedation of children undergoing magnetic resonance scans is indicated in guidelines, but no appropriate magnetic resonance-compatible devices are available. We report preliminary findings from a technique referred to as remote pressure sensor respiratory plethysmography. Methods: A data acquisition system was developed, enabling measurement of respiratory rate, plethysmogram amplitude, proportion of inspiratory time over cycle time, thoraco-abdominal phase shift and sigh rate. Correlation between plethysmogram amplitude and tidal volume was investigated on adult volunteers. Twenty-seven children undergoing sedation were monitored with remote pressure sensor respiratory plethysmography, in addition to SPO2 and PetCO2. Differences in monitoring parameters were searched for among three groups: patients who received chloral hydrate only (chloral succeeded, CS group), those who received a supplementation of sodium thiopental (chloral failed, CF group), and those who were sedated with sodium thiopental directly (no chloral, NC group). Correlations were searched for among monitoring parameters, and with total dose of thiopental. The long-term behaviour of respiratory rate, proportion of inspiratory time over cycle time and phase shift was studied. Results: Plethysmogram amplitude was found to correlate linearly with tidal volume (r > 0.92), with a slope varying up to 22%. While 11% of patients did not tolerate the capnometric probe and readings were discontinuous in 26%, all of them tolerated remote pressure sensor respiratory plethysmography belts. Sighs and non-respiratory movements of the torso could be distinguished on remote pressure sensor respiratory plethysmography waveforms. No significant inter-group differences were found in PetCO2, SPO2, respiratory rate and phase shift. Proportion of inspiratory time over cycle time was higher in the NC group when compared to the CS group (0.497 ± 0.03 vs. 0.463 ± 0.008; P = 0.02), the CF group being characterized by intermediate values (0.480 ± 0.008); when compared to the CS group, sigh rate was lower in the CF group (0.04 ± 0.04 vs. 0.14 ± 0.08; P = 0.04) and in the NC group (0.06 ± 0.05 vs. 0.14 ± 0.08, P = 0.03). A positive correlation was found between total dose of thiopental and proportion of inspiratory time over cycle time, with r = 0.4 and P = 0.04. A large baseline variability in phase shift was found. No long-term trends predictive of patient movement could be identified. Conclusions: Breathing pattern monitoring is feasible through pneumatic devices, which are well tolerated. The resulting correlation with changes in tidal volume can be better when compared to visual inspection. Proportion of inspiratory time over cycle time and sigh rate convey information related to the state of the sedated patient. These results are not specific to the technology employed, and large-scale studies on the clinical usefulness of breathing pattern monitoring are motivated.