HHHenrik Haraldsson

Henrik Haraldsson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Henrik Haraldsson has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Left Ventricular Chamber Shape During Vena Caval Occlusion: Improved MRI-based Measurement of the End-Systolic Pressure-Volume Relationship in Normal Sheep

    by Duc M. Giao, Yan Wang, Renan Rojas, Kiyoaki Takaba, Anusha Badathala, Kimberly A. Spaulding, Gilbert Soon, Yue Zhang, Vicky Y. Wang, Henrik Haraldsson, et al.

    The left ventricular (LV) end-systolic pressure volume relationship (ES; ESPVR) is the cornerstone of systolic LV function analysis. Recently, it became possible to measure 2D LV chamber shape during vena cava occlusion (VCO) with MRI. We used an improved level-set semi-automatic segmentation method (LSSM) to determine the effect of VCO on LV geometry, ES pressure area (PA) and ESPVR. 10 healthy adult sheep were anesthetized. LV pressure transducer and inferior vena cava (IVC) balloon catheter were percutaneously inserted. Ferumoxytol (0.125 ml/kg iv; AMAG Pharmaceuticals, Waltham, MA) was given to enhance blood pool contrast. LV pressure and 2D retrospectively-gated cine MRI of LV cross sections 25 (Apex), 50 (Mid) and 75% (Base) of the distance from the apex to the base of the LV were obtained during separate IVC balloon inflations (VCO). LV pressure was digitally filtered and LV chamber segmented with the LSSM. Cross sectional area, major and minor axes, major axis orientation, ESPAR and ESPVR were calculated. The LSSM had excellent reliability. All cross sections became more elliptical during VCO. The orientation (angle) of each major axis relative to the anterior RV insertion shifted during VCO. However, the orientation remained toward the septum. There was chamber collapse (LV area < 0.25 cm 2 ) at the apical level during VCO (7 cases). ESPAR was non-linear at all levels. ESPVR was non-linear because of apical collapse. In conclusion, MRI-based measurement of LV geometry, ESPAR and ESPVR during VCO is a valuable method that may lead to improved understanding of systolic LV function. New and Noteworthy: Real-time MRI was used to continuously measure the LV PA relationship as loading conditions were transiently varied in anesthetized sheep. All three examined cross-sections became more elliptical during VCO. The ESPAR were non-linear at all three cross-sections. Chamber collapse at the apical level during VCO resulted in a non-linear ESPVR. The heart contracted in a non-concentric manner during VCO which could inform modeling studies and elucidate mechanisms underlying LV adaptations to sudden load changes.

  • Assessment of Reynolds stress components and turbulent pressure loss using 4D flow MRI with extended motion encoding

    by Henrik Haraldsson, Sarah Kefayati, Sinyeob Ahn, Petter Dyverfeldt, Jonas Lantz, Matts Karlsson, Gerhard Laub, Tino Ebbers, David Saloner

    Purpose: To measure the Reynolds stress tensor using 4D flow MRI, and to evaluate its contribution to computed pressure maps.Methods: A method to assess both velocity and Reynolds stress using 4D flow MRI is presented and evaluated. The Reynolds stress is compared by cross‐sectional integrals of the Reynolds stress invariants. Pressure maps are computed using the pressure Poisson equation—both including and neglecting the Reynolds stress.Result: Good agreement is seen for Reynolds stress between computational fluid dynamics, simulated MRI, and MRI experiment. The Reynolds stress can significantly influence the computed pressure loss for simulated (eg, –0.52% vs –15.34% error; P < 0.001) and experimental (eg, 306 ± 11 vs 203 ± 6 Pa; P < 0.001) data. A 54% greater pressure loss is seen at the highest experimental flow rate when accounting for Reynolds stress (P < 0.001).Conclusion: 4D flow MRI with extended motion‐encoding enables quantification of both the velocity and the Reynolds stress tensor. The additional information provided by this method improves the assessment of pressure gradients across a stenosis in the presence of turbulence. Unlike conventional methods, which are only valid if the flow is laminar, the proposed method is valid for both laminar and disturbed flow, a common presentation in diseased vessels. Magn Reson Med 79:1962–1971, 2018. © 2017 International Society for Magnetic Resonance in Medicine.