MMMathias Meyer

Mathias Meyer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mathias Meyer has a total of 65 co-authors. Here are the top co-authors by number of shared publications:

  • Thomas Henzler

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim

    6 shared publications
  • Stefan O. Schoenberg

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim

    5 shared publications
  • Holger Haubenreisser

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim, Germany

    3 shared publications
  • Melissa M. Ong

    Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Mannheim

    3 shared publications
  • Bernhard Schmidt

    Imaging & Therapy Division, Siemens Healthcare, Forchheim, Germany

    2 shared publications
  • Christianne Leidecker

    Imaging & Therapy Division, Siemens Healthcare, Forchheim, Germany

    2 shared publications

Latest Publications

  • Detection of Calcified Aortic Plaques in an Apolipoprotein E Animal Model Using a Human Computed Tomography System for Ultra–High-resolution Imaging

    by Calin Manta, Mathias Meyer, Cyrill Géraud, Mareike Roscher, Sergij Goerdt, Stefan O. Schoenberg, Thomas Henzler, Melissa M. Ong

    The purpose of this study was to prospectively evaluate the feasibility of detecting calcified aortic plaques in apolipoprotein E knockout (ApoE-KO) mice using a state-of-the-art human computed tomography (CT) system. Eleven ApoE-KO and 9 wild-type mice, all male, were examined in this study. After intraperitoneal injection of 6.6% ketamine all mice underwent 2 ultra–high-resolution CT protocols on a third-generation dual-source CT system at 120 kVp and 130 kVp tube voltage, both performed with a tube current time product of 1300 mAs. Images (0.4 mm) with an increment of 0.2 mm were reconstructed using an iterative reconstruction algorithm. Calcium detectability and scores (Agatston, volume, mass) were determined with a dedicated human calcium scoring software (CaScoring). After the CT examination, a calcium quantification assay of the aortae was performed to determine the aortic calcium content of each mouse. The CT scan time ranged between 40 and 48 seconds. All mice survived the procedure. Calcified plaques could be detected in 8 of 11 ApoE-KO mice. Quantification of calcium levels showed significant differences between those with morphologic calcium plaques detected in CT and those without (3.44±1.6 μg Ca2+/mg vs. 0.33±0.35 μg Ca2+/mg; P<0.05). The receiver-operating characteristics analysis revealed a total calcium cut-off value of 0.71 μg Ca2+/mg for the detection using calcium score algorithms (specificity: 100% and sensitivity: 90%). Using a state-of-the-art human CT protocol and an in-human–established calcium scoring system allows for the detection and quantification of calcified aortic plaques in ApoE-KO mice. These results may facilitate preclinical imaging for translational and longitudinal atherosclerotic research studies.


  • Open Access

    CT pulmonary angiography in patients with acute or chronic renal insufficiency: Evaluation of a low dose contrast material protocol

    by Mathias Meyer, Holger Haubenreisser, Christoph Schabel, Christianne Leidecker, Bernhard Schmidt, Stefan O. Schoenberg, Thomas Henzler

    Adverse effects of intravenous contrast media (CM) in patients with renal risk factors and acute kidney injury are still controversially discussed. The aim of this study was to investigate whether dual-energy (DE) pulmonary CT angiography (CTPA) in combination with a noise optimized virtual monoenergetic imaging algorithm allows for a reduction of CM. This IRB-approved study comprised 150 patients with suspected pulmonary embolism (78 male; mean age 65 ± 17years). 50 patients with acute/chronic renal failure were examined on a 3rd generation dual-source CT with an optimized DE CTPA protocol and a low CM injection protocol (5.4 g iodine). 100 further patients were either examined with a standard CTPA protocol or a standard DE CTPA (32 g iodine). For the DE CTPA virtual monoenergetic spectral datasets (40–100 keV) were reconstructed. Main pulmonary arteries at 50 keV and peripheral pulmonary arteries at 40 keV datasets provided the highest contrast-to-noise-ratio (CNR) for both the standard DE CTPA and the optimized protocol, with significantly higher CNR values for the standard DE CTPA protocol (p < 0.05). No pulmonary embolism was missed on the optimized CM protocol. DE CTPA utilizing image reconstruction at 40/50 keV allowed for a reduction of 84% in iodine load while maintaining CNR, which is especially important in patients with acute/chronic renal failure.


  • Management of Progressive Pulmonary Nodules Found during and outside of CT Lung Cancer Screening Studies

    by Mathias Meyer, Rozemarijn Vliegenthart, Thomas Henzler, Daniel Buergy, Frank A. Giordano, Michael Kostrzewa, Nils Rathmann, Odd Terje Brustugun, Lucio Crino, Anne-Marie C. Dingemans, et al.


  • Coronary artery calcium quantification on first, second and third generation dual source CT: A comparison study

    by Marleen Vonder, Gert Jan Pelgrim, Sèvrin E.M. Huijsse, Holger Haubenreisser, Mathias Meyer, Peter M.A. van Ooijen, Matthijs Oudkerk, Thomas Henzler, Rozemarijn Vliegenthart


  • Open Access

    Imaging of Patients with Complex Hemodialysis Arterio-Venous Fistulas using Time-Resolved Dynamic CT Angiography: Comparison with Duplex Ultrasound

    by Mathias Meyer, Nicole Geiger, Urs Benck, Daniela Rose, Sonja Sudarski, Melissa M. Ong, Stefan O. Schoenberg, Thomas Henzler

    To evaluate the feasibility and potential on therapy management of time-resolved dynamic computed tomography angiography (dCTA) in patients with forearm arterio-venous fistula (AVF)/arterio-venous grafts (AVG). Thirty-five patients with complex failing forearm AVF/AVGs were examined with ultrasound and a dCTA protocol. Diagnosis and therapy management was evaluated versus duplex ultrasound (DUS) in three different readouts: 1. all dCTA datasets; 2. one arterial phase of the dCTA dataset; 3. one arterial and one venous dataset out of the dCTA dataset. All reads were performed >30 days apart from each other. Using all data of the dCTA examination, 20 patients were classified as having a stenosis >50%, 12 high-shunt flow, 11 partial thrombosis, 5 venous aneurysms and 5 complete thrombosis of their AVF/AVG grafts. This lead to 13 additional pathologic findings not visible on DUS and reclassification as normal in one patient with suspected AVF stenosis and complete thrombus on DUS. These additional findings lead to a direct change of therapeutic management in 8 patients. Compared to readout 1 (53 pathologies), readout number 2 and 3 revealed only 33 and 41 pathologies, respectively. dCTA provides additional information, improving diagnostic confidence and leading to changes in therapy management when compared to DUS alone.


  • Radiation Dose Levels of Retrospectively ECG-Gated Coronary CT Angiography Using 70-kVp Tube Voltage in Patients with High or Irregular Heart Rates

    by Mathias Meyer, Holger Haubenreisser, Uwe. Joseph Schoepf, Rozemarijn Vliegenthart, Melissa M. Ong, Christina Doesch, Sonja Sudarski, Martin Borggrefe, Stefan O. Schoenberg, Thomas Henzler


  • Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging

    by Mathias Meyer, Holger Haubenreisser, Rainer Raupach, Bernhard Schmidt, Florian Lietzmann, Christianne Leidecker, Thomas Allmendinger, Thomas Flohr, Lothar R. Schad, Stefan O. Schoenberg, et al.

    To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm2 removesthe necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63 %/39 % lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. • Omitting the z-axis-filter allows a reduction in radiation dose of 50 % • A smaller focal spot of 0.2 mm 2 significantly improves spatial resolution • Ultra-high-resolution temporal-bone-CT helps to gain diagnostic information of the middle/inner ear


  • Whole-body CT for lymphoma staging: Feasibility of halving radiation dose and risk by iterative image reconstruction

    by M. Meyer, S.A. Klein, G. Brix, C. Fink, L. Pilz, H. Jafarov, W.K. Hofmann, S.O. Schoenberg, T. Henzler