Hiroshi Hosoi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hiroshi Hosoi has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Tadashi Nishimura
Department of Otolaryngology-Head & Neck Surgery, Nara Medical University, Nara 634-8521, Japan
18 shared publications - Tadashi Kitahara
Department of Otolaryngology-Head and Neck surgery, Nara Medical University, Kashihara, Japan
10 shared publications - Ryota Shimokura
Department of Systems Science, Graduate School of Engineering Science, Osaka University, Toyonaka 560-8531, Japan
9 shared publications Toshiaki Yamanaka
Department of Otorhinolaryngology - Head and Neck Surgery, Nara Medical University
9 shared publications- Tadao Okayasu
Department of Otolaryngology-Head and Neck surgery, Nara Medical University, 840 Shijo-cho, Kashihara, Nara 634-8522, Japan
7 shared publications - Akinori Yamashita
Department of Otolaryngology-Head and Neck surgery, Nara Medical University, 840 Shijo-cho, Kashihara, Nara 634-8522, Japan
5 shared publications
Latest Publications
- Open Access
- 9 November 2023
- Published by MDPI AG in Audiology Research
- Vol. 13 (6) , 898-909
Cartilage Conduction Sounds in Cases of Wearing Different Transducers on a Head and Torso Simulator with a Manipulated Ear Pinna Simulator
Cartilage conduction is known widely as a third hearing transmission mechanism after the air and bone conduction methods, and transducers dedicated to the production of cartilage conduction sounds have been developed by several Japanese companies. To estimate the acoustic performance of the five cartilage conduction transducers selected for this study, both airborne sounds and cartilage conduction sounds were measured. Airborne sounds can be measured using a commercial condenser microphone; however, cartilage conduction sounds are impossible to measure using a conventional head and torso simulator (HATS), because the standard-issue ear pinna simulator cannot reproduce cartilage conduction sounds with the same spectral characteristics as the corresponding sounds measured in humans. Therefore, this study replaced the standard-issue simulator with a developed pinna simulator that can produce similar spectral characteristics to those of humans. The HATS manipulated in this manner realized results demonstrating that transducers that fitted the entrance to the external auditory canal more densely could produce greater cartilage conduction sounds. Among the five transducers under test, the ring-shaped device, which was not much larger than the entrance to the canal, satisfied the spectral requirements.
- 9 November 2023
- Published by MDPI AG in Audiology Research
- Vol. 13 (6) , 898-909
Open AccessCartilage Conduction Sounds in Cases of Wearing Different Transducers on a Head and Torso Simulator with a Manipulated Ear Pinna Simulator
Cartilage conduction is known widely as a third hearing transmission mechanism after the air and bone conduction methods, and transducers dedicated to the production of cartilage conduction sounds have been developed by several Japanese companies. To estimate the acoustic performance of the five cartilage conduction transducers selected for this study, both airborne sounds and cartilage conduction sounds were measured. Airborne sounds can be measured using a commercial condenser microphone; however, cartilage conduction sounds are impossible to measure using a conventional head and torso simulator (HATS), because the standard-issue ear pinna simulator cannot reproduce cartilage conduction sounds with the same spectral characteristics as the corresponding sounds measured in humans. Therefore, this study replaced the standard-issue simulator with a developed pinna simulator that can produce similar spectral characteristics to those of humans. The HATS manipulated in this manner realized results demonstrating that transducers that fitted the entrance to the external auditory canal more densely could produce greater cartilage conduction sounds. Among the five transducers under test, the ring-shaped device, which was not much larger than the entrance to the canal, satisfied the spectral requirements.
- Open Access
- 16 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8244
Relationship between Effective Duration and Intelligibility of Japanese Monosyllables in Individuals with Sensorineural Hearing Loss
Among the temporal elements in the autocorrelation function, the effective duration (τe) is a useful indicator of speech recognition for patients with sensorineural hearing impairment. We assessed the influence of speech recognition performance on the relationship between the percentage of accurately perceived articulation and the median τe (τe-med) and the relationship between monosyllabic confusion and the τe-med. Significant correlations were observed between the articulation percentage and the average τe-med in groups with high, middle, and low speech recognition scores (SRSs). Two-factor mixed analysis of variance revealed significant main effects for the condition (presentation/response). There was no significant main effect for group (high-, middle-, or low-SRS) scores and no significant interaction between the groups. The average τe-med of the response was significantly longer than that of the presentation in all three groups. Monosyllables with short τe-med values tended to be misheard as monosyllables with a long τe-med when confusion occurred. The τe-med was useful for estimating monosyllables that patients with sensorineural hearing impairment find easy to listen to, independent of speech recognition performance.
- 16 July 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (14) , 8244
Open AccessRelationship between Effective Duration and Intelligibility of Japanese Monosyllables in Individuals with Sensorineural Hearing Loss
Among the temporal elements in the autocorrelation function, the effective duration (τe) is a useful indicator of speech recognition for patients with sensorineural hearing impairment. We assessed the influence of speech recognition performance on the relationship between the percentage of accurately perceived articulation and the median τe (τe-med) and the relationship between monosyllabic confusion and the τe-med. Significant correlations were observed between the articulation percentage and the average τe-med in groups with high, middle, and low speech recognition scores (SRSs). Two-factor mixed analysis of variance revealed significant main effects for the condition (presentation/response). There was no significant main effect for group (high-, middle-, or low-SRS) scores and no significant interaction between the groups. The average τe-med of the response was significantly longer than that of the presentation in all three groups. Monosyllables with short τe-med values tended to be misheard as monosyllables with a long τe-med when confusion occurred. The τe-med was useful for estimating monosyllables that patients with sensorineural hearing impairment find easy to listen to, independent of speech recognition performance.
- Open Access
- 13 July 2023
- Published by MDPI AG in Audiology Research
- Vol. 13 (4) , 506-515
Cartilage Conduction Hearing Aids in Clinical Practice
A relatively loud sound is audible when a vibrator is attached to the aural cartilage. This form of conduction is referred to as cartilage conduction (CC). In Japan, a new type of hearing aid has been developed using CC and has been available in clinical practice since 2017. A clinical study conducted prior to its launch demonstrated its benefits, particularly in patients with aural atresia who were unable to use air conduction hearing aids. Several studies have been published on the benefits of CC hearing aids since their introduction into clinical practice. Most of the patients included in these studies had canal stenosis or aural atresia, and the purchase rates of CC hearing aids in these patients were relatively high. However, the number of patients with canal-open ears was small, with overall poor results in the trials, with the exception of patients with continuous otorrhea. CC hearing aids are considered a good option for compensating for hearing loss in ears with canal stenosis or atresia in both bilateral and unilateral cases. However, CC hearing aids are not currently considered the first choice for patients with a canal-open ear.
- 13 July 2023
- Published by MDPI AG in Audiology Research
- Vol. 13 (4) , 506-515
Open AccessCartilage Conduction Hearing Aids in Clinical Practice
A relatively loud sound is audible when a vibrator is attached to the aural cartilage. This form of conduction is referred to as cartilage conduction (CC). In Japan, a new type of hearing aid has been developed using CC and has been available in clinical practice since 2017. A clinical study conducted prior to its launch demonstrated its benefits, particularly in patients with aural atresia who were unable to use air conduction hearing aids. Several studies have been published on the benefits of CC hearing aids since their introduction into clinical practice. Most of the patients included in these studies had canal stenosis or aural atresia, and the purchase rates of CC hearing aids in these patients were relatively high. However, the number of patients with canal-open ears was small, with overall poor results in the trials, with the exception of patients with continuous otorrhea. CC hearing aids are considered a good option for compensating for hearing loss in ears with canal stenosis or atresia in both bilateral and unilateral cases. However, CC hearing aids are not currently considered the first choice for patients with a canal-open ear.
- Open Access
- 7 June 2023
- Published by MDPI AG in Preprints.org
Cartilage Conduction Hearing Aids in Clinical Practice
A relatively loud sound is audible when a vibrator is attached to the aural cartilage. This form of conduction is referred to as cartilage conduction (CC). In Japan, a new type of hearing aid has been developed using CC and is available in clinical practice since 2017. A clinical study conducted prior to its launch demonstrated its benefits, particularly in patients with aural atresia who were unable to use air-conduction hearing aids. Several studies have been published on the benefits of CC hearing aids since their introduction in clinical practice. Most of the patients included in these studies had canal stenosis or aural atresia, and the purchase rates of CC hearing aids in these patients were relatively high. However, the number of patients with open ears was small, with overall poor results in the trials, with the exception in patients with continuous otorrhea. CC hearing aids are considered a good option for compensating hearing loss in ears with canal stenosis or atresia in both bilateral and unilateral cases. However, CC hearing aids are not currently considered the first choice for patients with an open ear,.
- 7 June 2023
- Published by MDPI AG in Preprints.org
Open AccessCartilage Conduction Hearing Aids in Clinical Practice
A relatively loud sound is audible when a vibrator is attached to the aural cartilage. This form of conduction is referred to as cartilage conduction (CC). In Japan, a new type of hearing aid has been developed using CC and is available in clinical practice since 2017. A clinical study conducted prior to its launch demonstrated its benefits, particularly in patients with aural atresia who were unable to use air-conduction hearing aids. Several studies have been published on the benefits of CC hearing aids since their introduction in clinical practice. Most of the patients included in these studies had canal stenosis or aural atresia, and the purchase rates of CC hearing aids in these patients were relatively high. However, the number of patients with open ears was small, with overall poor results in the trials, with the exception in patients with continuous otorrhea. CC hearing aids are considered a good option for compensating hearing loss in ears with canal stenosis or atresia in both bilateral and unilateral cases. However, CC hearing aids are not currently considered the first choice for patients with an open ear,.
- Open Access
- 17 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6152
Comparison of Cartilage Conduction Hearing Devices Designed by Ear Impression and Computed Tomography
The ear molds and shells of hearing devices are generally designed using ear impressions. Computed tomography (CT) can provide information concerning ear structure, which can be utilized in computer-aided design to create hearing devices. This study aimed to compare the differences in hearing devices designed using either ear impressions or CT images. The ear chip of a cartilage conduction (CC) hearing device was designed based on the ear impression and CT images of patients with aural atresia. Three patients with bilateral (n = 1) or unilateral (n = 2) aural atresia participated in this study. The aided thresholds and subjective evaluations were compared. There were no serious problems with the use of either device, and no remarkable differences were observed regarding their respective audiological and subjective benefits. Regarding the subjective patient preferences, the hearing aid with the device designed via CT imaging was better in three ears of two patients, whereas the wearing comfort of the transducer was better for the device designed via the ear impression. The subjective evaluation of appearance varied among the cases. Finally, a device that was designed using CT findings was purchased for one patient. CT images can be utilized in computer-aided design to create CC hearing devices.
- 17 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6152
Open AccessComparison of Cartilage Conduction Hearing Devices Designed by Ear Impression and Computed Tomography
The ear molds and shells of hearing devices are generally designed using ear impressions. Computed tomography (CT) can provide information concerning ear structure, which can be utilized in computer-aided design to create hearing devices. This study aimed to compare the differences in hearing devices designed using either ear impressions or CT images. The ear chip of a cartilage conduction (CC) hearing device was designed based on the ear impression and CT images of patients with aural atresia. Three patients with bilateral (n = 1) or unilateral (n = 2) aural atresia participated in this study. The aided thresholds and subjective evaluations were compared. There were no serious problems with the use of either device, and no remarkable differences were observed regarding their respective audiological and subjective benefits. Regarding the subjective patient preferences, the hearing aid with the device designed via CT imaging was better in three ears of two patients, whereas the wearing comfort of the transducer was better for the device designed via the ear impression. The subjective evaluation of appearance varied among the cases. Finally, a device that was designed using CT findings was purchased for one patient. CT images can be utilized in computer-aided design to create CC hearing devices.
- Open Access
- 7 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12532
Manipulating the Hardness of HATS-Mounted Ear Pinna Simulators to Reproduce Cartilage Sound Conduction
Although hearing devices based on cartilage conduction have become more widely used in Japan, methods for evaluating the output volume of such devices have not yet been established. Although the output of air-conduction-based sound-generating devices (e.g., earphones and hearing aids) can be standardized via the head and torso simulator (HATS), this is not applicable to cartilage conduction devices because the simulated pinna is too soft (hardness: A5) compared with human aural cartilage. In this study, we developed polyurethane pinna that had the same shape but different degrees of hardness (A40, A20, and A10). We then compared the HATS results for the new pinna simulators with data from human ears. We found that the spectral shapes of the outputs increasingly approximated those of human ears as the simulated pinna hardness decreased. When a durometer was pressed against the ear tragus of a human ear, the hardness value ranged from A10 to A20. Accordingly, cartilage-conduction-based sound information could be obtained using a HATS that had a simulated pinna with a similar hardness value.
- 7 December 2022
- Published by MDPI AG in Applied Sciences
- Vol. 12 (24) , 12532
Open AccessManipulating the Hardness of HATS-Mounted Ear Pinna Simulators to Reproduce Cartilage Sound Conduction
Although hearing devices based on cartilage conduction have become more widely used in Japan, methods for evaluating the output volume of such devices have not yet been established. Although the output of air-conduction-based sound-generating devices (e.g., earphones and hearing aids) can be standardized via the head and torso simulator (HATS), this is not applicable to cartilage conduction devices because the simulated pinna is too soft (hardness: A5) compared with human aural cartilage. In this study, we developed polyurethane pinna that had the same shape but different degrees of hardness (A40, A20, and A10). We then compared the HATS results for the new pinna simulators with data from human ears. We found that the spectral shapes of the outputs increasingly approximated those of human ears as the simulated pinna hardness decreased. When a durometer was pressed against the ear tragus of a human ear, the hardness value ranged from A10 to A20. Accordingly, cartilage-conduction-based sound information could be obtained using a HATS that had a simulated pinna with a similar hardness value.
- Open Access
- 1 September 2022
- Published by MDPI AG in Audiology Research
- Vol. 12 (5) , 476-484
Evaluation of the Recovery of Idiopathic Sudden Sensorineural Hearing Loss Based on Estimated Hearing Disorders
Various prognostic factors for idiopathic sudden sensorineural hearing loss (SSNHL) have been reported. Hearing loss directly derived from idiopathic SSNHL is important for understanding underlying pathogenesis and outcomes. We assessed the usefulness of evaluating hearing loss and recovery of idiopathic SSNHL on the basis of estimated hearing loss. The study included 115 patients whose characteristics and outcomes of hearing loss were investigated. The effects of vertigo/dizziness and age on hearing thresholds before/after treatment, nonaffected ear threshold, estimated hearing loss, improvement of hearing loss, and estimated remaining hearing loss were investigated. Vertigo/dizziness was a significant prognostic factor for hearing. In vertigo/dizziness patients, significantly more severe hearing loss and poorer improvement of hearing loss were observed above 500 Hz and below 1000 Hz, respectively. Severe hearing disorder remained at all frequencies. Conversely, post-treatment thresholds were significantly higher in the older population (≥65 years), although no differences in pretreatment thresholds were observed between the younger (≤64 years) and older populations. However, on the basis of nonaffected ear thresholds, previously existing hearing loss could have influenced the outcome. Thus, comparison of hearing outcomes between affected and nonaffected ears is essential for understanding hearing loss and outcomes in idiopathic SSNHL cases with existing hearing disorder.
- 1 September 2022
- Published by MDPI AG in Audiology Research
- Vol. 12 (5) , 476-484
Open AccessEvaluation of the Recovery of Idiopathic Sudden Sensorineural Hearing Loss Based on Estimated Hearing Disorders
Various prognostic factors for idiopathic sudden sensorineural hearing loss (SSNHL) have been reported. Hearing loss directly derived from idiopathic SSNHL is important for understanding underlying pathogenesis and outcomes. We assessed the usefulness of evaluating hearing loss and recovery of idiopathic SSNHL on the basis of estimated hearing loss. The study included 115 patients whose characteristics and outcomes of hearing loss were investigated. The effects of vertigo/dizziness and age on hearing thresholds before/after treatment, nonaffected ear threshold, estimated hearing loss, improvement of hearing loss, and estimated remaining hearing loss were investigated. Vertigo/dizziness was a significant prognostic factor for hearing. In vertigo/dizziness patients, significantly more severe hearing loss and poorer improvement of hearing loss were observed above 500 Hz and below 1000 Hz, respectively. Severe hearing disorder remained at all frequencies. Conversely, post-treatment thresholds were significantly higher in the older population (≥65 years), although no differences in pretreatment thresholds were observed between the younger (≤64 years) and older populations. However, on the basis of nonaffected ear thresholds, previously existing hearing loss could have influenced the outcome. Thus, comparison of hearing outcomes between affected and nonaffected ears is essential for understanding hearing loss and outcomes in idiopathic SSNHL cases with existing hearing disorder.
- Open Access
- 13 August 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (3) , 410-417
Clinical Trial for Cartilage Conduction Hearing Aid in Indonesia
Hearing improvement represents one of the may valuable outcomes in microtia and aural atresia reconstruction surgery. Most patients with poor development in their hearing function have had a severe microtia. Conventional methods to improve hearing function are bone conduction and bone anchored hearing aids. Cartilage conduction hearing aids (CCHA) represents a new amplification method. This study assessed the outcomes and evaluated the impact and its safety in the patients with microtia and aural atresia whose hearing dysfunction did not improve after surgery for ear reconstruction in our hospital. Hearing functions were evaluated with pure tone audiometry or sound field testing by behavioral audiometry and speech audiometry before and after CCHA fitting. As a result, there was a significant difference between unaided and aided thresholds (p < 0.001). Speech recognition threshold and speech discrimination level also significantly improved with CCHA. The average functional gains of 14 ears were 26.9 ± 2.3 dB. Almost all parents of the patients reported satisfaction with the performance of CCHA, and daily communication in children with hearing loss also became better than usual.
- 13 August 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (3) , 410-417
Open AccessClinical Trial for Cartilage Conduction Hearing Aid in Indonesia
Hearing improvement represents one of the may valuable outcomes in microtia and aural atresia reconstruction surgery. Most patients with poor development in their hearing function have had a severe microtia. Conventional methods to improve hearing function are bone conduction and bone anchored hearing aids. Cartilage conduction hearing aids (CCHA) represents a new amplification method. This study assessed the outcomes and evaluated the impact and its safety in the patients with microtia and aural atresia whose hearing dysfunction did not improve after surgery for ear reconstruction in our hospital. Hearing functions were evaluated with pure tone audiometry or sound field testing by behavioral audiometry and speech audiometry before and after CCHA fitting. As a result, there was a significant difference between unaided and aided thresholds (p < 0.001). Speech recognition threshold and speech discrimination level also significantly improved with CCHA. The average functional gains of 14 ears were 26.9 ± 2.3 dB. Almost all parents of the patients reported satisfaction with the performance of CCHA, and daily communication in children with hearing loss also became better than usual.
- Open Access
- 14 July 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (3) , 357-364
Word Categorization of Vowel Durational Changes in Speech-Modulated Bone-Conducted Ultrasound
Ultrasound can deliver speech information when it is amplitude-modulated with speech and presented via bone conduction. This speech-modulated bone-conducted ultrasound (SM-BCU) can also transmit prosodic information. However, there is insufficient research on the recognition of vowel duration in SM-BCU. The aim of this study was to investigate the categorization of vowel durational changes in SM-BCU using a behavioral test. Eight Japanese-speaking participants with normal hearing participated in a forced-choice behavioral task to discriminate between “hato” (pigeon) and “haato” (heart). Speech signal stimuli were presented in seven duration grades from 220 ms to 340 ms. The threshold at which 50% of responses were “haato” was calculated and compared for air-conducted audible sound (ACAS) and SM-BCU. The boundary width was also evaluated. Although the SM-BCU threshold (mean: 274.6 ms) was significantly longer than the ACAS threshold (mean: 269.6 ms), there were no differences in boundary width. These results suggest that SM-BCU can deliver prosodic information about vowel duration with a similar difference limen to that of ACAS in normal hearing.
- 14 July 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (3) , 357-364
Open AccessWord Categorization of Vowel Durational Changes in Speech-Modulated Bone-Conducted Ultrasound
Ultrasound can deliver speech information when it is amplitude-modulated with speech and presented via bone conduction. This speech-modulated bone-conducted ultrasound (SM-BCU) can also transmit prosodic information. However, there is insufficient research on the recognition of vowel duration in SM-BCU. The aim of this study was to investigate the categorization of vowel durational changes in SM-BCU using a behavioral test. Eight Japanese-speaking participants with normal hearing participated in a forced-choice behavioral task to discriminate between “hato” (pigeon) and “haato” (heart). Speech signal stimuli were presented in seven duration grades from 220 ms to 340 ms. The threshold at which 50% of responses were “haato” was calculated and compared for air-conducted audible sound (ACAS) and SM-BCU. The boundary width was also evaluated. Although the SM-BCU threshold (mean: 274.6 ms) was significantly longer than the ACAS threshold (mean: 269.6 ms), there were no differences in boundary width. These results suggest that SM-BCU can deliver prosodic information about vowel duration with a similar difference limen to that of ACAS in normal hearing.
- Open Access
- 1 July 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (3) , 327-334
Vibrational and Acoustical Characteristics of Ear Pinna Simulators That Differ in Hardness
Because cartilage conduction—the transmission of sound via the aural cartilage—has different auditory pathways from well-known air and bone conduction, how the output volume in the external auditory canal is stimulated remains unknown. To develop a simulator approximating the conduction of sound in ear cartilage, the vibrations of the pinna and sound in the external auditory canal were measured using pinna simulators made of silicon rubbers of different hardness (A40, A20, A10, A5, A0) as measured by a durometer. The same procedure, as well as a current calibration method for air conduction devices, was applied to an existing pinna simulator, the Head and Torso Simulator (hardness A5). The levels for vibration acceleration and sound pressure from these pinna simulators show spectral peaks at dominant frequencies (below 1.5 kHz) for the conduction of sound in cartilage. These peaks were likely to move to lower frequencies as hardness decreases. On approaching the hardness of actual aural cartilage (A10 to A20), the simulated levels for vibration acceleration and sound pressure approximated the measurements of human ears. The adjustment of the hardness used in pinna simulators is an important factor in simulating accurately the conduction of sound in cartilage.
- 1 July 2021
- Published by MDPI AG in Audiology Research
- Vol. 11 (3) , 327-334
Open AccessVibrational and Acoustical Characteristics of Ear Pinna Simulators That Differ in Hardness
Because cartilage conduction—the transmission of sound via the aural cartilage—has different auditory pathways from well-known air and bone conduction, how the output volume in the external auditory canal is stimulated remains unknown. To develop a simulator approximating the conduction of sound in ear cartilage, the vibrations of the pinna and sound in the external auditory canal were measured using pinna simulators made of silicon rubbers of different hardness (A40, A20, A10, A5, A0) as measured by a durometer. The same procedure, as well as a current calibration method for air conduction devices, was applied to an existing pinna simulator, the Head and Torso Simulator (hardness A5). The levels for vibration acceleration and sound pressure from these pinna simulators show spectral peaks at dominant frequencies (below 1.5 kHz) for the conduction of sound in cartilage. These peaks were likely to move to lower frequencies as hardness decreases. On approaching the hardness of actual aural cartilage (A10 to A20), the simulated levels for vibration acceleration and sound pressure approximated the measurements of human ears. The adjustment of the hardness used in pinna simulators is an important factor in simulating accurately the conduction of sound in cartilage.