JSJuan Sieira

Juan Sieira

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Juan Sieira has a total of 44 co-authors. Here are the top co-authors by number of shared publications:

  • Pedro Brugada

    Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium

    8 shared publications
  • Giulio Conte

    Cardiocentro Ticino Institute, Ente Ospedaliero Cantonale, Lugano, Switzerland

    7 shared publications
  • Yukio Saitoh

    Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium

    6 shared publications
  • Carlo de Asmundis

    Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Heart Rhythm Research Brussels, Postgraduate Program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium

    5 shared publications
  • Giacomo Di Giovanni

    Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium

    5 shared publications
  • Giannis Baltogiannis

    Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel, Postgraduate program in Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium

    5 shared publications

Latest Publications

  • Long-term prognosis of drug-induced Brugada syndrome

    by Juan Sieira, Giuseppe Ciconte, Giulio Conte, Carlo de Asmundis, Gian-Battista Chierchia, Giannis Baltogiannis, Giacomo Di Giovanni, Yukio Saitoh, Ruben Casado-Arroyo, Justo Juliá, et al.


  • Top Cited Papers
    Open Access

    A score model to predict risk of events in patients with Brugada Syndrome

    by Juan Sieira, Giulio Conte, Giuseppe Ciconte, Gian-Battista Chierchia, Ruben Casado-Arroyo, Giannis Baltogiannis, Giacomo Di Giovanni, Yukio Saitoh, Justo Juliá, Giacomo Mugnai, et al.

    Aims: Risk stratification in Brugada Syndrome (BS) remains challenging. Arrhythmic events can occur life-long and studies with long follow-ups are sparse. The aim of our study was to investigate long-term prognosis and risk stratification of BS patients. Methods and results: A single centre consecutive cohort of 400 BS patients was included and analysed. Mean age was 41.1 years, 78 patients (19.5%) had a spontaneous type I electrocardiogram (ECG). Clinical presentation was aborted sudden cardiac death (SCD) in 20 patients (5.0%), syncope in 111 (27.8%) and asymptomatic in 269 (67.3%). Familial antecedents of SCD were found in 184 individuals (46.0%), in 31 (7.8%) occurred in first-degree relatives younger than 35 years. An implantable cardioverter defibrillator (ICD) was placed in 176 (44.0%). During a mean follow-up of 80.7 months, 34 arrhythmic events occurred (event rate: 1.4% year). Variables significantly associated to events were: presentation as aborted SCD (Hazard risk [HR] 20.0), syncope (HR 3.7), spontaneous type I (HR 2.7), male gender (HR 2.7), early SCD in first-degree relatives (HR 2.9), SND (HR 5.0), inducible VA (HR 4.7) and proband status (HR 2.1). A score including ECG pattern, early familial SCD antecedents, inducible electrophysiological study, presentation as syncope or as aborted SCD and SND had a predictive performance of 0.82. A score greater than 2 conferred a 5-year event probability of 9.2%. Conclusions: BS patients remain at risk many years after diagnosis. Early SCD in first-degree relatives and SND are risk factors for arrhythmic events. A simple risk score might help in the stratification and management of BS patients.


  • Brugada Syndrome: Defining the Risk in Asymptomatic Patients

    by Juan Sieira, Pedro Brugada

    Since the first description of the Brugada syndrome (BS) in 1992, scientific progress in the understanding of this disease has been enormous; at the same time more and more individuals with the disease have been diagnosed. The profile of patients with BS has changed with more asymptomatic individuals and less expressive clinical features. Asymptomatic BS individuals are at lower arrhythmic risk than those presenting with syncope or sudden cardiac death (SCD). The event incidence rate is around 0.5 % per year; this figure is relevant due to the fact that individuals have a long life expectancy and are otherwise healthy. As a result of the risk of SCD, risk stratification is of utmost importance. As the implantation of a cardioverter defibrillator is the main treatment for those patients at higher risk, benefits and long-term potential risks have to be adequately considered. Some risk factors, such as spontaneous type 1 electrocardiogram (ECG) pattern, are widely accepted, whilst for others contradictory data are present. Furthermore, novel risk factors are now available that might help in the management of BS. The presence of a spontaneous type 1 ECG pattern, history of sinus node dysfunction and inducible ventricular arrhythmias during programmed electrical stimulation of the heart allow us to risk stratify these patients.


  • Asymptomatic Brugada Syndrome

    by Juan Sieira, Giuseppe Ciconte, Giulio Conte, Gian-Battista Chierchia, Carlo de Asmundis, Giannis Baltogiannis, Giacomo Di Giovanni, Yukio Saitoh, Ghazala Irfan, Rubén Casado-Arroyo, et al.

    Background—: Among Brugada syndrome patients, asymptomatic individuals are considered to be at the lowest risk. Nevertheless, arrhythmic events and sudden cardiac death are not negligible. Literature focused on this specific group of patients is sparse. The purpose of this study is to investigate the clinical characteristics, management, and long-term prognosis of asymptomatic Brugada syndrome patients. Methods and Results—: Patients presenting with spontaneous or drug-induced Brugada type I ECG and no symptoms at our institution were considered eligible. A total of 363 consecutive patients (200 men, 55.1%; mean age, 40.9±17.2 years; 41 [11.3%] with spontaneous type I ECG) were included. Electrophysiological study was performed in 321 (88.4%) patients, and ventricular arrhythmias were induced in 32 (10%) patients. An implantable cardioverter defibrillator was implanted in 61 (16.8%) patients. After a mean follow-up time of 73.2±58.9 months, 9 arrhythmic events occurred, accounting for an annual incidence rate of 0.5%. Event-free survival was 99.0% at 1 year, 96.2% at 5 years, and 95.4% at 10 and 15 years. Univariate analysis identified as risk factors: electrophysiological study inducibility (hazard ratio, 11.4; P P =0.04), and previous sinus node dysfunction (hazard ratio, 8.0; 95% confidence interval, 1.0–63.9; P =0.05). At the multivariate analysis, only inducibility remained significant (hazard ratio, 9.1; P <0.01) Conclusions—: Arrhythmic events in asymptomatic Brugada syndrome patients are not insignificant. Ventricular arrhythmia inducibility, spontaneous type I ECG, and presence of sinus node dysfunction might be considered as risk factors and used to drive long-term management.


    • 4 August 2015
      • Vol. 56  (4) , 279-84

    Contribution of the Endothelin System to the Genesis and Maintenance of Atrial Fibrillation: Review of the Literature and Clinical Implications.

    by Giannis G Baltogiannis, Theofilos M Kolettis, Gian Battista Chierchia, Juan Sieira, Giacomo Di Giovanni, Pedro Brugada


  • Prognostic Value of Programmed Electrical Stimulation in Brugada Syndrome

    by Juan Sieira, Giulio Conte, Giuseppe Ciconte, Carlo de Asmundis, Gian-Battista Chierchia, Giannis Baltogiannis, Giacomo Di Giovanni, Yukio Saitoh, Ghazala Irfan, Ruben Casado-Arroyo, et al.

    Background—: The prognostic value of electrophysiological investigations in individuals with Brugada syndrome remains controversial. Different groups have published contradictory data. Long-term follow-up is needed to clarify this issue. Methods and Results—: Patients presenting with spontaneous or drug-induced Brugada type I ECG and in whom programmed electric stimulation was performed at our institution were considered eligible for this study. A total of 403 consecutive patients (235 males, 58.2%; mean age, 43.2±16.2 years) were included. Ventricular arrhythmias during programmed electric stimulation were induced in 73 (18.1%) patients. After a mean follow-up time of 74.3±57.3 months (median 57.3), 25 arrhythmic events occurred (16 in the inducible group and 9 in the noninducible). Ventricular arrhythmias inducibility presented a hazard ratio for events of 8.3 (95% confidence interval, 3.6–19.4), P <0.01. Conclusions—: Programmed ventricular stimulation of the heart is a good predictor of outcome in individuals with Brugada syndrome. It might be of special value to guide further management when performed in asymptomatic individuals. The overall accuracy of the test makes it a suitable screening tool to reassure noninducible asymptomatic individuals


  • Spontaneous and Adenosine‐Induced Pulmonary Vein Reconnection After Cryoballoon Ablation with the Second‐Generation Device

    by Giuseppe Ciconte, Gian‐Battista Chierchia, Carlo DE Asmundis, Juan Sieira, Giulio Conte, Justo Juliá, Giacomo DI Giovanni, Kristel Wauters, Giannis Baltogiannis, Yukio Saitoh, et al.

    Longer observational time and adenosine challenge have proven to be able to detect pulmonary vein (PV) reconnections. The aim of this study was to assess incidence of spontaneous and adenosine-induced PV reconnection after ablation with second-generation cryoballoon (CB-Adv). Fifty consecutive patients (76% male, mean age 60.5 ± 11.9 years) having undergone PV isolation (PVI) using the CB-Adv were enrolled. After isolation, reconnections were evaluated using the Achieve catheter over 30 minutes observation and adenosine administration during isoproterenol infusion (adenosine challenge). Among 200 PVs, isolation was achieved in 190 (95%) during the first application. Lower nadir temperature and longer rewarming time were associated with successful PVI (P = 0.02 and 0.04). Spontaneous (4 veins) and adenosine-induced (4 veins) PV reconnections occurred in the 4% of initially isolated veins (8 veins) in 6 patients (12%). At receiver–operator curve analysis, nadir temperature <–51 °C and rewarming time >28 seconds identified absence of reconnections (sensitivity 100% and 87%, area under the curve 0.75 and 0.72). Patients with right-sided early branching frequently experienced reconnections (P < 0.01). After a mean follow-up of 7.0 ± 1.7 months, 86% of patients were free from atrial fibrillation. None of those with PV reconnections experienced recurrences. The incidence of spontaneous and adenosine-induced PV reconnection following ablation with the novel CB-Adv is very low occurring in 4% of initially isolated veins. Nadir temperature <−51 °C and rewarming time >28 seconds identified absence of acute reconnections, thus avoiding prolonged waiting time and adenosine challenge in such cases.


  • One Year Incidence of Iatrogenic Atrial Septal Defect After Cryoballoon Ablation for Atrial Fibrillation

    by Juan Sieira, Gian‐Battista Chierchia, Giacomo DI Giovanni, Giulio Conte, Carlo DE Asmundis, Andrea Sarkozy, Steven Droogmans, Giannis Baltogiannis, Yukio Saitoh, Giuseppe Ciconte, et al.

    Pulmonary vein (PV) isolation by means of cryoballoon (CB) technology is an effective treatment for symptomatic paroxysmal atrial fibrillation (AF) refractory to antiarrhythmic drug therapy. The CB requires a 15F transseptal sheath that may lead to the creation of a iatrogenic atrial septal defect (IASD). Individuals having undergone PV isolation by the means of CB ablation and a subsequent transesophageal echocardiography (TEE) examination during postablation follow-up were consecutively included. Thirty-nine patients formed the study group (31 male, 76.9%; mean age 57.4 ± 13.7 years). IASD was present in 8 (20%) of them after a mean follow-up time of 11.7 months. Mean diameter of the defect was 0.57 cm × 0.48 cm; only left to right shunt was observed. No adverse events were recorded in these patients during the follow-up. IASD after CB ablation of AF is present in up to 20% of patients after 1 year. Although no adverse clinical events were recorded in patients with persistence of IASD, this complication should not be underestimated and systematic echocardiographic examinations might be advised at regular intervals in the follow-up period after CB. Further studies with larger population and follow-up might be required to confirm our findings.


  • Atrial fibrillation outcomes: Changing the paradigm

    by Ruben Casado-Arroyo, Gian Battista Chierchia, Moisés Rodriguez-Mañero, Moisés Levinstein, Mehdi Namdar, Giulio Conte, Juan Sieira, Andrea Sarkozy, Carlo de Asmundis, Kristel Wauters, et al.


  • Open Access

    "Giant R wave" electrocardiogram pattern during exercise treadmill test: A case report

    by Ana Testa-Fernández, Ramón Rios-Vazquez, Juan Sieira-Rodríguez-Moret, Raúl Franco-Gutierrez, Carlos Peña-Gil, Ruth Pérez-Fernández, Victor Puebla-Rojo, Margarita Regueiro-Abel, Carlos Gonzalez-Juanatey

    The exercise treadmill test is widely used in the evaluation of patients with suspected or known coronary artery disease. The typical ischemic response used to be ST-segment depression.