Ethan J. Halpern
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Ethan J. Halpern has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Leonard G. Gomella
4 shared publicationsFerdinand Frauscher
3 shared publicationsLevon N. Nazarian
2 shared publicationsPatrick O’kAne
2 shared publicationsStephen E. Strup
2 shared publicationsAnne K. Aksnes
1 shared publication
Latest Publications
- 1 October 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 225 (1) , 71-77
Prostate: High-Frequency Doppler US Imaging for Cancer Detection
To evaluate cancer detection with targeted biopsy of the prostate performed on the basis of high-frequency Doppler ultrasonographic (US) imaging findings versus cancer detection with a modified sextant biopsy approach with laterally directed cores. Sixty-two patients were prospectively evaluated with gray-scale, color, and power Doppler transrectal US performed with patients in the lithotomy position. Gray-scale and Doppler findings within each sextant were rated on a five-point scale. Up to four targeted biopsy specimens were obtained from each patient on the basis of Doppler findings; this was followed by a modified sextant biopsy. Conditional logistic regression analysis was performed to compare the positive yields for targeted and sextant biopsy specimens. Clustered receiver operating characteristic analysis was performed to compare gray-scale, color, and power Doppler detection of cancer at sextant biopsy sites. Cancer was detected in 18 (29%) of 62 patients, including 11 patients in whom cancer was detected with both sextant and targeted biopsy, six in whom cancer was detected only with sextant biopsy, and one in whom cancer was detected only with targeted biopsy. The positive biopsy rate for targeted biopsy (24 [13%] of 185 cores) was slightly higher than that for sextant biopsy (36 [9.7%] of 372 cores; P =.1). The odds ratio for cancer detection with targeted versus sextant cores was 1.8 (95% CI: 0.9, 3.7). Receiver operating characteristic analysis demonstrated that overall identification of positive sextant biopsy sites was close to random chance for gray-scale (area under the curve, 0.53), color Doppler (area under the curve, 0.50), and power Doppler (area under the curve, 0.47) imaging. Targeted biopsy performed on the basis of high-frequency color or power Doppler findings will miss a substantial number of cancers detected with sextant biopsy.
- 1 October 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 225 (1) , 71-77
Prostate: High-Frequency Doppler US Imaging for Cancer Detection
To evaluate cancer detection with targeted biopsy of the prostate performed on the basis of high-frequency Doppler ultrasonographic (US) imaging findings versus cancer detection with a modified sextant biopsy approach with laterally directed cores. Sixty-two patients were prospectively evaluated with gray-scale, color, and power Doppler transrectal US performed with patients in the lithotomy position. Gray-scale and Doppler findings within each sextant were rated on a five-point scale. Up to four targeted biopsy specimens were obtained from each patient on the basis of Doppler findings; this was followed by a modified sextant biopsy. Conditional logistic regression analysis was performed to compare the positive yields for targeted and sextant biopsy specimens. Clustered receiver operating characteristic analysis was performed to compare gray-scale, color, and power Doppler detection of cancer at sextant biopsy sites. Cancer was detected in 18 (29%) of 62 patients, including 11 patients in whom cancer was detected with both sextant and targeted biopsy, six in whom cancer was detected only with sextant biopsy, and one in whom cancer was detected only with targeted biopsy. The positive biopsy rate for targeted biopsy (24 [13%] of 185 cores) was slightly higher than that for sextant biopsy (36 [9.7%] of 372 cores; P =.1). The odds ratio for cancer detection with targeted versus sextant cores was 1.8 (95% CI: 0.9, 3.7). Receiver operating characteristic analysis demonstrated that overall identification of positive sextant biopsy sites was close to random chance for gray-scale (area under the curve, 0.53), color Doppler (area under the curve, 0.50), and power Doppler (area under the curve, 0.47) imaging. Targeted biopsy performed on the basis of high-frequency color or power Doppler findings will miss a substantial number of cancers detected with sextant biopsy.
- 1 March 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (3) , 634-639
High-Frequency Doppler US of the Prostate: Effect of Patient Position
To evaluate cancer detection with directed biopsy of the prostate on the basis of high-frequency Doppler ultrasonographic (US) findings, and to determine the effect of patient position on the observed flow pattern. Thirty-two patients were evaluated in the left lateral decubitus position with gray-scale, color Doppler, and power Doppler transrectal US. Up to four directed biopsy specimens were obtained on the basis of gray-scale and Doppler US findings, and modified sextant biopsy followed. Analysis of variance and the Wilcoxon signed rank test were used to evaluate the distribution of Doppler signals within the prostate. Three healthy volunteers with no known prostate disease were also examined in supine and both decubitus positions. In the patient group, both color and power Doppler US demonstrated increased flow on the left side of the prostate, with greater flow toward the base of the gland (P <.002). Consequently, 62 of 90 directed-biopsy cores were obtained in the left base and mid-gland. The positive biopsy rate for directed biopsy was not significantly different from that of sextant biopsy (P =.4). Seven patients had cancer that was identified with sextant biopsy, but only four cancers were identified with directed biopsy. Each of the three healthy volunteers demonstrated increased Doppler flow on the dependent side when the subject was in the lateral decubitus position. The positive yield of directed biopsy was similar to the yield of sextant biopsy. On the basis of observations made in healthy volunteers, the authors conclude that flow asymmetry in patients who underwent biopsy may have been related to patient position.
- 1 March 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (3) , 634-639
High-Frequency Doppler US of the Prostate: Effect of Patient Position
To evaluate cancer detection with directed biopsy of the prostate on the basis of high-frequency Doppler ultrasonographic (US) findings, and to determine the effect of patient position on the observed flow pattern. Thirty-two patients were evaluated in the left lateral decubitus position with gray-scale, color Doppler, and power Doppler transrectal US. Up to four directed biopsy specimens were obtained on the basis of gray-scale and Doppler US findings, and modified sextant biopsy followed. Analysis of variance and the Wilcoxon signed rank test were used to evaluate the distribution of Doppler signals within the prostate. Three healthy volunteers with no known prostate disease were also examined in supine and both decubitus positions. In the patient group, both color and power Doppler US demonstrated increased flow on the left side of the prostate, with greater flow toward the base of the gland (P <.002). Consequently, 62 of 90 directed-biopsy cores were obtained in the left base and mid-gland. The positive biopsy rate for directed biopsy was not significantly different from that of sextant biopsy (P =.4). Seven patients had cancer that was identified with sextant biopsy, but only four cancers were identified with directed biopsy. Each of the three healthy volunteers demonstrated increased Doppler flow on the dependent side when the subject was in the lateral decubitus position. The positive yield of directed biopsy was similar to the yield of sextant biopsy. On the basis of observations made in healthy volunteers, the authors conclude that flow asymmetry in patients who underwent biopsy may have been related to patient position.
- 1 February 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (2) , 361-366
Contrast-enhanced US of the Prostate with Sonazoid: Comparison with Whole-Mount Prostatectomy Specimens in 12 Patients
To compare areas of contrast material enhancement in the prostate at ultrasonography (US) with whole-mount radical prostatectomy specimens to determine if the use of contrast material improves the detection rate of prostate cancer. Transrectal US was performed in 12 subjects with cancer of the prostate prior to radical prostatectomy. Each gland was evaluated with conventional gray-scale and wide-band harmonic US at baseline and again during intravenous infusion of a microbubble contrast agent. Focal areas of contrast enhancement were identified prospectively in the transverse plane at the base, midgland, and apex of the prostate. US findings were then compared with whole-mount prostatectomy specimens. Baseline and contrast-enhanced findings were compared by using the Wilcoxon signed rank test. Thirty-one foci of prostate cancer were present at pathologic evaluation, with multiple foci of cancer in 11 of the 12 glands. Three of 10 inner-gland cancers and five of 21 outer-gland cancers were detected at baseline imaging. Diffuse inner-gland enhancement was identified in all subjects during contrast agent infusion. Contrast-enhanced imaging demonstrated an additional five cancer foci in the outer gland (P =.025), for an overall sensitivity of 42% (13 of 31 foci). Seven additional sites of focal contrast enhancement were identified. Five of these sites corresponded to foci of hyperplasia. Two sites were false-positive with no pathologic abnormality. Increased flow was not demonstrated posteriorly in the midline, even when a tumor was present. Contrast-enhanced US of the prostate with Sonazoid can improve sensitivity for the detection of cancers in the outer gland, but it can also demonstrate focal enhancement in areas of benign hyperplasia.
- 1 February 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 222 (2) , 361-366
Contrast-enhanced US of the Prostate with Sonazoid: Comparison with Whole-Mount Prostatectomy Specimens in 12 Patients
To compare areas of contrast material enhancement in the prostate at ultrasonography (US) with whole-mount radical prostatectomy specimens to determine if the use of contrast material improves the detection rate of prostate cancer. Transrectal US was performed in 12 subjects with cancer of the prostate prior to radical prostatectomy. Each gland was evaluated with conventional gray-scale and wide-band harmonic US at baseline and again during intravenous infusion of a microbubble contrast agent. Focal areas of contrast enhancement were identified prospectively in the transverse plane at the base, midgland, and apex of the prostate. US findings were then compared with whole-mount prostatectomy specimens. Baseline and contrast-enhanced findings were compared by using the Wilcoxon signed rank test. Thirty-one foci of prostate cancer were present at pathologic evaluation, with multiple foci of cancer in 11 of the 12 glands. Three of 10 inner-gland cancers and five of 21 outer-gland cancers were detected at baseline imaging. Diffuse inner-gland enhancement was identified in all subjects during contrast agent infusion. Contrast-enhanced imaging demonstrated an additional five cancer foci in the outer gland (P =.025), for an overall sensitivity of 42% (13 of 31 foci). Seven additional sites of focal contrast enhancement were identified. Five of these sites corresponded to foci of hyperplasia. Two sites were false-positive with no pathologic abnormality. Increased flow was not demonstrated posteriorly in the midline, even when a tumor was present. Contrast-enhanced US of the prostate with Sonazoid can improve sensitivity for the detection of cancers in the outer gland, but it can also demonstrate focal enhancement in areas of benign hyperplasia.
- 1 April 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 219 (1) , 219-225
Prostate Cancer: Contrast-enhanced US for Detection
To assess the detection of prostate cancer with contrast material-enhanced transrectal sonography. Sixty subjects were examined with conventional gray-scale, harmonic gray-scale, and power Doppler sonography. Evaluation was repeated during intravenous infusion of contrast agent. Gray-scale imaging was performed in continuous mode and with intermittent imaging by using interscan delay times of 0.5, 1.0, 2.0, and 5.0 seconds. Sextant biopsy sites were scored prospectively as benign or malignant at baseline imaging and again during enhanced transrectal sonography. Prostate cancer was present in 37 biopsy sites from 20 subjects. Baseline imaging demonstrated prostate cancer in 14 sites in 11 subjects. Enhanced transrectal sonography depicted prostate cancer in 24 sites in 15 subjects. Each of the five subjects in whom prostate cancer was missed had only a single biopsy core with positive findings (Gleason score < or = 6). In three of these five subjects, prostate cancer made up less than 10% of the core. The improvement in sensitivity from 38% (14 of 37 malignant foci) at baseline to 65% (24 of 37 malignant foci) with contrast enhancement was significant (P<.004, McNemar chi(2) test). Specificity was similar at baseline (267 [83%] of 323 malignant foci) and during enhanced transrectal sonography (257 [80%] of 323 malignant foci). Clustered receiver operating characteristic analysis demonstrated significant improvement in diagnostic accuracy during enhanced transrectal sonography (P =.027). Enhanced transrectal sonography improves sensitivity for the detection of malignant foci within the prostate without substantial loss of specificity. Low-volume tumors with a Gleason score of 6 or less may not be detected with enhanced transrectal sonography.
- 1 April 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 219 (1) , 219-225
Prostate Cancer: Contrast-enhanced US for Detection
To assess the detection of prostate cancer with contrast material-enhanced transrectal sonography. Sixty subjects were examined with conventional gray-scale, harmonic gray-scale, and power Doppler sonography. Evaluation was repeated during intravenous infusion of contrast agent. Gray-scale imaging was performed in continuous mode and with intermittent imaging by using interscan delay times of 0.5, 1.0, 2.0, and 5.0 seconds. Sextant biopsy sites were scored prospectively as benign or malignant at baseline imaging and again during enhanced transrectal sonography. Prostate cancer was present in 37 biopsy sites from 20 subjects. Baseline imaging demonstrated prostate cancer in 14 sites in 11 subjects. Enhanced transrectal sonography depicted prostate cancer in 24 sites in 15 subjects. Each of the five subjects in whom prostate cancer was missed had only a single biopsy core with positive findings (Gleason score < or = 6). In three of these five subjects, prostate cancer made up less than 10% of the core. The improvement in sensitivity from 38% (14 of 37 malignant foci) at baseline to 65% (24 of 37 malignant foci) with contrast enhancement was significant (P<.004, McNemar chi(2) test). Specificity was similar at baseline (267 [83%] of 323 malignant foci) and during enhanced transrectal sonography (257 [80%] of 323 malignant foci). Clustered receiver operating characteristic analysis demonstrated significant improvement in diagnostic accuracy during enhanced transrectal sonography (P =.027). Enhanced transrectal sonography improves sensitivity for the detection of malignant foci within the prostate without substantial loss of specificity. Low-volume tumors with a Gleason score of 6 or less may not be detected with enhanced transrectal sonography.
- 1 August 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 216 (2) , 434-439
Preoperative Evaluation of Living Renal Donors: Comparison of CT Angiography and MR Angiography
To compare computed tomographic (CT) angiography and magnetic resonance (MR) angiography for preoperative evaluation of living renal donors. Thirty-five living renal donors underwent preoperative contrast material-enhanced CT angiography and gadolinium-enhanced MR angiography. Each study was interpreted by two independent radiologists blinded to all other studies and to interpretations provided by other reviewers. Eighteen kidneys had surgical correlation. CT demonstrated 33 supernumerary arteries in 19 patients, bilateral solitary arteries in 16 patients, and 18 proximal arterial branches in 16 patients. MR demonstrated 26 supernumerary arteries in 15 patients, bilateral solitary renal arteries in 20 patients, and 21 proximal arterial branches in 16 patients. Interobserver agreements for MR (kappa = 0. 74) and CT (kappa = 0.73) were similar to the agreement between MR and CT (kappa = 0.74). Among the kidneys chosen for nephrectomy, one small accessory artery and one proximal arterial branch were missed with CT and MR. Two of the accessory arteries suggested at CT were not found at nephrectomy. By averaging data for both modalities, supernumerary arteries were present in 49% of kidney donors and were bilateral in approximately 17%. Proximal arterial branches were present in 46% of kidney donors. Preoperative CT and MR angiography of the renal arteries in renal donors demonstrate substantial agreement. Interobserver disagreement in the interpretation of CT and MR angiograms is related to 1-2-mm-diameter vessels.
- 1 August 2000
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 216 (2) , 434-439
Preoperative Evaluation of Living Renal Donors: Comparison of CT Angiography and MR Angiography
To compare computed tomographic (CT) angiography and magnetic resonance (MR) angiography for preoperative evaluation of living renal donors. Thirty-five living renal donors underwent preoperative contrast material-enhanced CT angiography and gadolinium-enhanced MR angiography. Each study was interpreted by two independent radiologists blinded to all other studies and to interpretations provided by other reviewers. Eighteen kidneys had surgical correlation. CT demonstrated 33 supernumerary arteries in 19 patients, bilateral solitary arteries in 16 patients, and 18 proximal arterial branches in 16 patients. MR demonstrated 26 supernumerary arteries in 15 patients, bilateral solitary renal arteries in 20 patients, and 21 proximal arterial branches in 16 patients. Interobserver agreements for MR (kappa = 0. 74) and CT (kappa = 0.73) were similar to the agreement between MR and CT (kappa = 0.74). Among the kidneys chosen for nephrectomy, one small accessory artery and one proximal arterial branch were missed with CT and MR. Two of the accessory arteries suggested at CT were not found at nephrectomy. By averaging data for both modalities, supernumerary arteries were present in 49% of kidney donors and were bilateral in approximately 17%. Proximal arterial branches were present in 46% of kidney donors. Preoperative CT and MR angiography of the renal arteries in renal donors demonstrate substantial agreement. Interobserver disagreement in the interpretation of CT and MR angiograms is related to 1-2-mm-diameter vessels.