Jane P. Ko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jane P. Ko has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- David P. Naidich
Department of Radiology, New York University-Langone Medical Center, New York, NY
4 shared publications - Georgeann McGuinness
Department of Radiology, New York University Medical Center, New York 10016, USA
2 shared publications Henry Rusinek
2 shared publicationsJo-Anne O. Shepard
2 shared publicationsMargrit Betke
2 shared publicationsAmi N. Rubinowitz
1 shared publication
Latest Publications
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 19 (3) , 136-155
Computer-Aided Diagnosis and the Evaluation of Lung Disease
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 19 (3) , 136-155
Computer-Aided Diagnosis and the Evaluation of Lung Disease
- 1 September 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (3) , 864-870
Small Pulmonary Nodules: Volume Measurement at Chest CT—Phantom Study
Three-dimensional methods for quantifying pulmonary nodule volume at computed tomography (CT) and the effect of imaging variables were studied by using a realistic phantom. Two fixed-threshold methods, a partial-volume method (PVM) and a variable method, were used to calculate volumes of 40 plastic nodules (largest dimension, <5 mm: 20 nodules with solid attenuation and 20 with ground-glass attenuation) of known volume. Tube current times (20 and 120 mAs), reconstruction algorithms (high and low frequency), and nodule characteristics were studied. Higher precision was associated with use of a PVM with predetermined pure nodule attenuation, high-frequency algorithm, and diagnostic CT technique (120 mAs). A PVM is promising for volume quantification and follow-up of nodules. © RSNA, 2003
- 1 September 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (3) , 864-870
Small Pulmonary Nodules: Volume Measurement at Chest CT—Phantom Study
Three-dimensional methods for quantifying pulmonary nodule volume at computed tomography (CT) and the effect of imaging variables were studied by using a realistic phantom. Two fixed-threshold methods, a partial-volume method (PVM) and a variable method, were used to calculate volumes of 40 plastic nodules (largest dimension, <5 mm: 20 nodules with solid attenuation and 20 with ground-glass attenuation) of known volume. Tube current times (20 and 120 mAs), reconstruction algorithms (high and low frequency), and nodule characteristics were studied. Higher precision was associated with use of a PVM with predetermined pure nodule attenuation, high-frequency algorithm, and diagnostic CT technique (120 mAs). A PVM is promising for volume quantification and follow-up of nodules. © RSNA, 2003
- 1 July 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (1) , 70-75
Wavelet Compression of Low-Dose Chest CT Data: Effect on Lung Nodule Detection
PURPOSE: To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS: One hundred sets of lung CT data (“cases”) were compressed to 30:1, 20:1, and 10:1 levels by using a wavelet-based JPEG2000 method, resulting in 400 test cases. Each case consisted of nine 1.25-mm sections that had been obtained with 20–40 mAs. Four thoracic radiologists independently interpreted the test case images. Performance was measured by using area under the receiver operating characteristic (ROC) curve (Az) and conventional sensitivity and specificity analyses. RESULTS: There were 51 cases with and 49 without lung nodules. Az values were 0.984, 0.988, 0.972, 0.921, respectively, for original and 10:1, 20:1, and 30:1 compressed images. Az values decreased significantly at 30:1 (P = .014) but not at 10:1 compression, with a trend toward significant decrease at 20:1 (P = .051). Spec...
- 1 July 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (1) , 70-75
Wavelet Compression of Low-Dose Chest CT Data: Effect on Lung Nodule Detection
PURPOSE: To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS: One hundred sets of lung CT data (“cases”) were compressed to 30:1, 20:1, and 10:1 levels by using a wavelet-based JPEG2000 method, resulting in 400 test cases. Each case consisted of nine 1.25-mm sections that had been obtained with 20–40 mAs. Four thoracic radiologists independently interpreted the test case images. Performance was measured by using area under the receiver operating characteristic (ROC) curve (Az) and conventional sensitivity and specificity analyses. RESULTS: There were 51 cases with and 49 without lung nodules. Az values were 0.984, 0.988, 0.972, 0.921, respectively, for original and 10:1, 20:1, and 30:1 compressed images. Az values decreased significantly at 30:1 (P = .014) but not at 10:1 compression, with a trend toward significant decrease at 20:1 (P = .051). Spec...
- 1 May 2003
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 41 (3) , 575-597
Lung nodule detection and characterization with multislice CT
- 1 May 2003
- Published by Elsevier in Radiologic Clinics of North America
- Vol. 41 (3) , 575-597
Lung nodule detection and characterization with multislice CT
- 1 January 2002
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 17 (1) , 70-73
Pulmonary Aspergillosis in an Immunocompetent Patient
A case of an immunocompetent patient with severe Aspergillus infection and radiographic findings typically described with angioinvasive aspergillosis is presented. When Aspergillus is isolated from the sputum in a patient with normal immunity, invasive aspergillosis should be considered when there are extensive radiographic findings characteristic of invasive fungal disease.
- 1 January 2002
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 17 (1) , 70-73
Pulmonary Aspergillosis in an Immunocompetent Patient
A case of an immunocompetent patient with severe Aspergillus infection and radiographic findings typically described with angioinvasive aspergillosis is presented. When Aspergillus is isolated from the sputum in a patient with normal immunity, invasive aspergillosis should be considered when there are extensive radiographic findings characteristic of invasive fungal disease.
- 1 February 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 218 (2) , 491-496
Factors Influencing Pneumothorax Rate at Lung Biopsy: Are Dwell Time and Angle of Pleural Puncture Contributing Factors?
To study factors that may influence pneumothorax and chest tube placement rate, especially needle dwell time and pleural puncture angle. In 159 patients, 160 coaxial computed tomography (CT)-guided lung biopsies were performed. Dwell time, the time between pleural puncture and needle removal, was calculated. The smallest angle of the needle with the pleura ("needle-pleural angle") was measured. These and other variables were correlated with pneumothorax and chest tube rates. One hundred fifty biopsies were included. There were 58 (39%) pneumothoraces (14 noted only at CT), with eight (5%) biopsies resulting in chest tube placement. Longer dwell times (mean, 29 minutes; range, 12-66 minutes) did not correlate with pneumothoraces (P =.81). Smaller needle-pleural angles (< 80 degrees) [corrected], decreased forced expiratory volume in 1 second to vital capacity ratio (<50%), lateral pleural puncture, and lesions along fissures were associated with higher [corrected] pneumothorax rates (P <.05). Emphysema along the needle path, pulmonary function tests showing ventilatory obstruction, and lesions along fissures predisposed patients to chest tube placement (P <.05). Pleural thickening and prior surgery were associated with lower pneumothorax rates (P <.05). Longer dwell times do not correlate with pneumothorax and should not influence the decision to obtain more biopsy samples. A shallow pleural puncture angle may increase the pneumothorax rate.
- 1 February 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 218 (2) , 491-496
Factors Influencing Pneumothorax Rate at Lung Biopsy: Are Dwell Time and Angle of Pleural Puncture Contributing Factors?
To study factors that may influence pneumothorax and chest tube placement rate, especially needle dwell time and pleural puncture angle. In 159 patients, 160 coaxial computed tomography (CT)-guided lung biopsies were performed. Dwell time, the time between pleural puncture and needle removal, was calculated. The smallest angle of the needle with the pleura ("needle-pleural angle") was measured. These and other variables were correlated with pneumothorax and chest tube rates. One hundred fifty biopsies were included. There were 58 (39%) pneumothoraces (14 noted only at CT), with eight (5%) biopsies resulting in chest tube placement. Longer dwell times (mean, 29 minutes; range, 12-66 minutes) did not correlate with pneumothoraces (P =.81). Smaller needle-pleural angles (< 80 degrees) [corrected], decreased forced expiratory volume in 1 second to vital capacity ratio (<50%), lateral pleural puncture, and lesions along fissures were associated with higher [corrected] pneumothorax rates (P <.05). Emphysema along the needle path, pulmonary function tests showing ventilatory obstruction, and lesions along fissures predisposed patients to chest tube placement (P <.05). Pleural thickening and prior surgery were associated with lower pneumothorax rates (P <.05). Longer dwell times do not correlate with pneumothorax and should not influence the decision to obtain more biopsy samples. A shallow pleural puncture angle may increase the pneumothorax rate.
- 1 January 1999
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 245-252
Detection of Pulmonary Nodules on CT and Volumetric Assessment of Change over Time
- 1 January 1999
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 245-252
Detection of Pulmonary Nodules on CT and Volumetric Assessment of Change over Time