RWRichard Watts

Richard Watts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard Watts has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Martin R. Prince

    Department of Radiology, Weill Cornell Medicine, New York, NY

    3 shared publications
  • Neil M. Khilnani

    All authors: Department of Radiology, Weill Medical College of Cornell University, 416 E 55th St., Cornell MRI, New York, NY 10022

    2 shared publications
  • Priscilla A. Winchester

    All authors: Department of Radiology, Weill Medical College of Cornell University, 416 E 55th St., Cornell MRI, New York, NY 10022

    2 shared publications
  • Yi Wang

    All authors: Department of Radiology, Weill Medical College of Cornell University, 416 E 55th St., Cornell MRI, New York, NY 10022

    2 shared publications
  • Hale Ersoy

    Department of Radiology, Weill Medical College of Cornell University, New York, New York, USA

    1 shared publication
  • Harry L. Bush

    Department of Vascular Surgery, Weill Medical College of Cornell University, New York, New York

    1 shared publication

Latest Publications

  • Diagnostic Accuracy of Time-Resolved 2D Projection MR Angiography for Symptomatic Infrapopliteal Arterial Occlusive Disease

    by Hong Lei Zhang, Neil M. Khilnani, Martin R. Prince, Priscilla A. Winchester, Piyush Golia, Patrick Veit, Richard Watts, Yi Wang

    OBJECTIVE. Our objective was to evaluate the diagnostic accuracy of time-resolved 2D projection MR angiography in detecting calf and pedal artery occlusive disease. MATERIALS AND METHODS. Time-resolved MR angiography of calf and pedal arteries was performed on 59 symptomatic legs of 52 patients using the head coil and bolus injections of 6 mL of gadolinium contrast medium. Selective X-ray digital subtraction angiography was performed within 30 days after MR angiography. Calf and pedal arteries were divided into 10 segments. X-ray digital subtraction angiography and MR angiography images were retrospectively interpreted by three expert observers, who graded segments as having no significant stenosis, significant stenosis (> 50%), or occlusion. The accuracy of MR angiography interpretations was compared with the accuracy of consensus X-ray digital subtraction angiography interpretations as the standard of reference. Arterial segments with discrepant grading on X-ray digital subtraction angiography and MR angiography were reviewed again to determine the reasons for disagreement. RESULTS. Arterial phase MR angiography images free of venous contamination were obtained in every case. The agreement between MR angiography and X-ray digital subtraction angiography in depicting infrapopliteal arterial disease was fair to good (κ = 0.44–0.92). Overall sensitivity and specificity were 83% and 87%, respectively, for detecting significant stenosis of calf and pedal arteries and 86% and 93%, respectively, for detecting occlusions. Accuracy was higher in the larger vessels—for example, calf (84%) compared with foot (71%). In 21% (22/105) of the segments graded differently on MR angiography than on X-ray digital subtraction angiography, it was believed that MR angiography was more likely to be correct than X-ray digital subtraction angiography because of visualization of late-filling arteries on MR angiography that did not opacify on X-ray digital subtraction angiography. CONCLUSION. Time-resolved 2D projection MR angiography accurately evaluates calf and pedal arteries without degradation from venous contamination.


  • Atherosclerotic disease distribution in carotid and vertebrobasilar arteries: Clinical experience in 100 patients undergoing fluoro-triggered 3D Gd-MRA

    by Hale Ersoy, Richard Watts, Pina Sanelli, Robert D. Zimmerman, K. Craig Kent, Harry L. Bush, Martin R. Prince

    Purpose To determine how often three‐dimensional gadolinium‐enhanced magnetic resonance angiography (3D Gd‐MRA) shows disease outside of the standard two‐dimensional time‐of‐flight magnetic resonance angiography (2D TOF‐MRA) imaging volume. Materials and Methods One hundred consecutive patients with known or suspected cerebrovascular disease were examined using fluoro‐triggered 3D Gd‐MRA with a 1.5 Tesla scanner. All vessel segments from the aortic arch to the circle of Willis were independently evaluated for the presence of occlusive disease, ulceration, aneurysm, and anatomic variations by two radiologists blinded to clinical information. Branch vessel and circle of Willis visibility were also assessed. Kappa statistics were calculated to determine interobserver agreement. Results Interobserver agreement for the degree of stenosis was good to excellent (κ = 0.83–1.0). Disagreement was more frequent in the cases of mild stenoses and was less frequent for stenoses ≥ 50%. In 38% of the patients, 3D Gd‐MRA demonstrated either ulcerated plaques in carotid arteries (N = 14) or stenosis ≥ 50% in great vessel (N = 20) and/or vertebral artery (N = 38) origins, none of which can be readily evaluated on standard TOF‐MRA. Conclusion Fluoro‐triggered 3D Gd‐MRA provides a comprehensive evaluation of the carotid arteries including all vessel segments from the aortic arch to the circle of Willis. J. Magn. Reson. Imaging 2003;17:545–558.


  • Anatomically Tailored k-Space Sampling for Bolus-Chase Three-dimensional MR Digital Subtraction Angiography

    by Richard Watts, Yi Wang, Martin R. Prince, Priscilla A. Winchester, Neil M. Khilnani, K. Craig Kent

    The purpose of this study was to evaluate a variable k-space sampling method for bolus-chase three-dimensional magnetic resonance digital subtraction angiography in the arterial system from the abdomen to the calf. Imaging time was minimized by tailoring the acquisition according to the vascular anatomy of the station. For images obtained in 30 patients, results with the modified protocol were compared to those with the previously published protocol. For all stations, significant improvement (P <.001) was found with the modified protocol.