Jacob A. Quick
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jacob A. Quick has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Stephen L. Barnes
University of Missouri
7 shared publications Alex D. Bukoski
University of Missouri, College of Veterinary Medicine, Columbia, Missouri
3 shared publicationsMegan Crane
University of Missouri, School of Medicine, Department of Surgery, Columbia, Missouri
3 shared publicationsBethany J. Bennett
University of Missouri, School of Medicine, Department of Surgery, Columbia, Missouri
2 shared publicationsJennifer Doty
University of Missouri, School of Medicine, Department of Surgery, Columbia, Missouri
2 shared publications- Salman Ahmad
Salman Ahmad, MD, FACS, is Assistant Professor of Surgery, Medical Director Surgical Intensive Care Unit, Acute Care Surgery Division, Department of Surgery, University of Missouri Healthcare, Columbia, Missouri
2 shared publications
Latest Publications
- 1 August 2021
- Published by Elsevier in Surgical Clinics of North America
- Vol. 101 (4) , 667-677
Evidence-Based Selection of Surgical Residents
- 1 August 2021
- Published by Elsevier in Surgical Clinics of North America
- Vol. 101 (4) , 667-677
Evidence-Based Selection of Surgical Residents
- 1 March 2019
- Published by Elsevier in Journal of Surgical Education
- Vol. 76 (2) , 354-361
Case Difficulty, Postgraduate Year, and Resident Surgeon Stress: Effects on Operative Times
- 1 March 2019
- Published by Elsevier in Journal of Surgical Education
- Vol. 76 (2) , 354-361
Case Difficulty, Postgraduate Year, and Resident Surgeon Stress: Effects on Operative Times
- 1 January 2019
- Published by Elsevier in Journal of Surgical Education
- Vol. 76 (1) , 234-241
Surgical Simulation: Markers of Proficiency
- 1 January 2019
- Published by Elsevier in Journal of Surgical Education
- Vol. 76 (1) , 234-241
Surgical Simulation: Markers of Proficiency
- 6 November 2018
- Vol. 115 (5) , 447-450
Simulation Training in Trauma.
Trauma care is the classic high-acuity event for which simulation training has the potential to greatly improve outcomes. While not a new concept, the variability and availability of training modalities in trauma continues to rapidly multiply. Spanning the continuum of fidelity, simulation extends from simple trauma scenario discussion, to advanced virtual reality experiences. The choice of simulation is largely dependent upon the desired outcome, which is broadly divided into either task-oriented or non-technical skill acquisition.
- 6 November 2018
- Vol. 115 (5) , 447-450
Simulation Training in Trauma.
Trauma care is the classic high-acuity event for which simulation training has the potential to greatly improve outcomes. While not a new concept, the variability and availability of training modalities in trauma continues to rapidly multiply. Spanning the continuum of fidelity, simulation extends from simple trauma scenario discussion, to advanced virtual reality experiences. The choice of simulation is largely dependent upon the desired outcome, which is broadly divided into either task-oriented or non-technical skill acquisition.
- 1 June 2018
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 28 (6) , 736-739
Laparoscopic Management of Penetrating Thoracoabdominal Trauma
Background: Traumatic thoracoabdominal injuries can involve multiple organs and multiple cavities, which increases the complexity of surgical management. Traditionally, these injuries required laparotomy and thoracotomy. However, minimally invasive intervention may be reasonable for stable patients. Materials and Methods: We present a case of a thoracoabdominal gunshot wound resulting in multiorgan, multicavity injury to the lung, diaphragm, and liver. We performed hepatorrhaphy and diaphragm repair, and addressed a retained hemothorax through a transabdominal laparoscopic approach. Results: The patient tolerated the procedure well. He required no further procedures, and had no evidence of retained hemothorax or bile leak from the liver injury. After a short stay in the hospital, the patient recovered uneventfully. Conclusions: In hemodynamically stable patients, the transabdominal laparoscopic approach is a feasible and effective approach to penetrating thoracoabdominal trauma.
- 1 June 2018
- Published by SAGE Publications in Journal of Laparoendoscopic & Advanced Surgical Techniques
- Vol. 28 (6) , 736-739
Laparoscopic Management of Penetrating Thoracoabdominal Trauma
Background: Traumatic thoracoabdominal injuries can involve multiple organs and multiple cavities, which increases the complexity of surgical management. Traditionally, these injuries required laparotomy and thoracotomy. However, minimally invasive intervention may be reasonable for stable patients. Materials and Methods: We present a case of a thoracoabdominal gunshot wound resulting in multiorgan, multicavity injury to the lung, diaphragm, and liver. We performed hepatorrhaphy and diaphragm repair, and addressed a retained hemothorax through a transabdominal laparoscopic approach. Results: The patient tolerated the procedure well. He required no further procedures, and had no evidence of retained hemothorax or bile leak from the liver injury. After a short stay in the hospital, the patient recovered uneventfully. Conclusions: In hemodynamically stable patients, the transabdominal laparoscopic approach is a feasible and effective approach to penetrating thoracoabdominal trauma.
- 13 March 2018
- Published by SAGE Publications in Respiratory Care
- Vol. 63 (8) , 950-954
Pulmonary Contusion in Mechanically Ventilated Subjects After Severe Trauma
BACKGROUND: Pulmonary contusions are thought to worsen outcomes. We aimed to evaluate the effects of pulmonary contusion on mechanically ventilated trauma subjects with severe thoracic injuries and hypothesized that contusion would not increase morbidity. METHODS: We conducted a single-center, retrospective review of 163 severely injured trauma subjects (injury severity score ≥ 15) with severe thoracic injury (chest abbreviated injury score ≥ 3), who required mechanical ventilation for >24 h at a verified Level 1 trauma center. Subject data were analyzed for those with radiographic documentation of pulmonary contusion and those without. Statistical analysis was performed to determine the effects of coexisting pulmonary contusion in severe thoracic trauma. RESULTS: Pulmonary contusion was present in 91 subjects (55.8%), whereas 72 (44.2%) did not have pulmonary contusions. Mean chest abbreviated injury score (3.54 vs 3.47, P = .53) and mean injury severity score (32.6 vs 30.2, P = .12) were similar. There was no difference in mortality (11 [12.1%] vs 9 [12.5%], P > .99) or length of stay (16.29 d vs 17.29 d, P = .60). Frequency of ventilator-associated pneumonia was comparable (43 [47.3%] vs 32 [44.4%], P = .75). Subjects with contusions were more likely to grow methicillin-sensitive Staphylococcus aureus in culture (33 vs 10, P = .004) as opposed to Pseudomonas aeruginosa in culture (6 vs 13, P = .003). CONCLUSIONS: Overall, no significant differences were noted in mortality, length of stay, or pneumonia rates between severely injured trauma subjects with and without pulmonary contusions.
- 13 March 2018
- Published by SAGE Publications in Respiratory Care
- Vol. 63 (8) , 950-954
Pulmonary Contusion in Mechanically Ventilated Subjects After Severe Trauma
BACKGROUND: Pulmonary contusions are thought to worsen outcomes. We aimed to evaluate the effects of pulmonary contusion on mechanically ventilated trauma subjects with severe thoracic injuries and hypothesized that contusion would not increase morbidity. METHODS: We conducted a single-center, retrospective review of 163 severely injured trauma subjects (injury severity score ≥ 15) with severe thoracic injury (chest abbreviated injury score ≥ 3), who required mechanical ventilation for >24 h at a verified Level 1 trauma center. Subject data were analyzed for those with radiographic documentation of pulmonary contusion and those without. Statistical analysis was performed to determine the effects of coexisting pulmonary contusion in severe thoracic trauma. RESULTS: Pulmonary contusion was present in 91 subjects (55.8%), whereas 72 (44.2%) did not have pulmonary contusions. Mean chest abbreviated injury score (3.54 vs 3.47, P = .53) and mean injury severity score (32.6 vs 30.2, P = .12) were similar. There was no difference in mortality (11 [12.1%] vs 9 [12.5%], P > .99) or length of stay (16.29 d vs 17.29 d, P = .60). Frequency of ventilator-associated pneumonia was comparable (43 [47.3%] vs 32 [44.4%], P = .75). Subjects with contusions were more likely to grow methicillin-sensitive Staphylococcus aureus in culture (33 vs 10, P = .004) as opposed to Pseudomonas aeruginosa in culture (6 vs 13, P = .003). CONCLUSIONS: Overall, no significant differences were noted in mortality, length of stay, or pneumonia rates between severely injured trauma subjects with and without pulmonary contusions.
- 1 October 2017
- Published by Elsevier in Journal of Surgical Research
- Vol. 218, 144-149
Surgical resident technical skill self-evaluation: increased precision with training progression
- 1 October 2017
- Published by Elsevier in Journal of Surgical Research
- Vol. 218, 144-149
Surgical resident technical skill self-evaluation: increased precision with training progression
- 25 September 2015
- Published by Springer Nature in Emergency Radiology
- Vol. 23 (1) , 3-7
In-flight ultrasound identification of pneumothorax
Ultrasound is a standard adjunct to the initial evaluation of injured patients in the emergency department. We sought to evaluate the ability of prehospital, in-flight thoracic ultrasound to identify pneumothorax. Non-physician aeromedical providers were trained to perform and interpret thoracic ultrasound. All adult trauma patients and adult medical patients requiring endotracheal intubation underwent both in-flight and emergency department ultrasound evaluations. Findings were documented independently and reviewed to ensure quality and accuracy. Results were compared to chest X-ray and computed tomography (CT). One hundred forty-nine patients (136 trauma/13 medical) met inclusion criteria. Mean age was 44.4 (18–94) years; 69 % were male. Mean injury severity score was 17.68 (1–75), and mean chest injury score was 2.93 (0–6) in the injured group. Twenty pneumothoraces and one mainstem intubation were identified. Sixteen pneumothoraces were correctly identified in the field. A mainstem intubation was misinterpreted. When compared to chest CT (n = 116), prehospital ultrasound had a sensitivity of 68 % (95 % confidence interval (CI) 46–85 %), a specificity of 96 % (95 % CI 90–98 %), and an overall accuracy of 91 % (95 % CI 85–95 %). In comparison, emergency department (ED) ultrasound had a sensitivity of 84 % (95 % CI 62–94 %), specificity of 98 % (95 % CI 93–99 %), and an accuracy of 96 % (95 % CI 90–98 %). The unique characteristics of the aeromedical environment render the auditory element of a reliable physical exam impractical. Thoracic ultrasonography should be utilized to augment the diagnostic capabilities of prehospital aeromedical providers.
- 25 September 2015
- Published by Springer Nature in Emergency Radiology
- Vol. 23 (1) , 3-7
In-flight ultrasound identification of pneumothorax
Ultrasound is a standard adjunct to the initial evaluation of injured patients in the emergency department. We sought to evaluate the ability of prehospital, in-flight thoracic ultrasound to identify pneumothorax. Non-physician aeromedical providers were trained to perform and interpret thoracic ultrasound. All adult trauma patients and adult medical patients requiring endotracheal intubation underwent both in-flight and emergency department ultrasound evaluations. Findings were documented independently and reviewed to ensure quality and accuracy. Results were compared to chest X-ray and computed tomography (CT). One hundred forty-nine patients (136 trauma/13 medical) met inclusion criteria. Mean age was 44.4 (18–94) years; 69 % were male. Mean injury severity score was 17.68 (1–75), and mean chest injury score was 2.93 (0–6) in the injured group. Twenty pneumothoraces and one mainstem intubation were identified. Sixteen pneumothoraces were correctly identified in the field. A mainstem intubation was misinterpreted. When compared to chest CT (n = 116), prehospital ultrasound had a sensitivity of 68 % (95 % confidence interval (CI) 46–85 %), a specificity of 96 % (95 % CI 90–98 %), and an overall accuracy of 91 % (95 % CI 85–95 %). In comparison, emergency department (ED) ultrasound had a sensitivity of 84 % (95 % CI 62–94 %), specificity of 98 % (95 % CI 93–99 %), and an accuracy of 96 % (95 % CI 90–98 %). The unique characteristics of the aeromedical environment render the auditory element of a reliable physical exam impractical. Thoracic ultrasonography should be utilized to augment the diagnostic capabilities of prehospital aeromedical providers.
- 1 May 2015
- Published by Elsevier in The Lancet
- Vol. 385 (9982) , 2024-2026
Correct coagulopathy: quickly and effectively
- 1 May 2015
- Published by Elsevier in The Lancet
- Vol. 385 (9982) , 2024-2026
Correct coagulopathy: quickly and effectively
- 19 September 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 21 (1) , 11-15
Provider X-ray exposure in the trauma bay: results of a radiation field analysis
Radiation exposure during trauma care has increased in recent years. Radiation risk to providers during the care of injured patients is not well defined. We aimed to gather environmental exposure data from dosimeters placed at fixed points in the trauma bay to act as surrogates for personnel radiation exposure during trauma team activations. Forty-four (44) radiation dosimeters were placed throughout a single trauma bay in a university level 1 trauma center. We analyzed shallow (SDE) and deep dose equivalents (DDE) over 6 months. We measured distance from the radiation source for each dosimeter. Four controls were included. We recorded patient injury and X-ray data for each patient. During the study period, 417 patients were evaluated in the trauma bay under study. Mean ISS was 14.3 (range 0-75). A total of 2,107 plain X-rays were taken, with a mean of 5.1 X-rays per patient (range 0-32). Extremity films were most often performed, followed by chest and shoulder films. No measurable dose was identified with the dosimeter controls. The majority (27, 68 %) of dosimeters registered the lowest doses (<1 mSv DDE). Five dosimeters revealed doses between 1 and 2 mSv DDE. Four dosimeters registered over 2 mSv DDE, with a mean DDE of 3 mSv. Distances of less than 5 ft from the radiation source had the highest DDE dose. Maximum annual occupational DDE dose is conventionally 50 mSv. None of the dosimeters registered DDE doses over 4.31 mSv during the study period, supporting low radiation risk to providers in the trauma bay.
- 19 September 2013
- Published by Springer Nature in Emergency Radiology
- Vol. 21 (1) , 11-15
Provider X-ray exposure in the trauma bay: results of a radiation field analysis
Radiation exposure during trauma care has increased in recent years. Radiation risk to providers during the care of injured patients is not well defined. We aimed to gather environmental exposure data from dosimeters placed at fixed points in the trauma bay to act as surrogates for personnel radiation exposure during trauma team activations. Forty-four (44) radiation dosimeters were placed throughout a single trauma bay in a university level 1 trauma center. We analyzed shallow (SDE) and deep dose equivalents (DDE) over 6 months. We measured distance from the radiation source for each dosimeter. Four controls were included. We recorded patient injury and X-ray data for each patient. During the study period, 417 patients were evaluated in the trauma bay under study. Mean ISS was 14.3 (range 0-75). A total of 2,107 plain X-rays were taken, with a mean of 5.1 X-rays per patient (range 0-32). Extremity films were most often performed, followed by chest and shoulder films. No measurable dose was identified with the dosimeter controls. The majority (27, 68 %) of dosimeters registered the lowest doses (<1 mSv DDE). Five dosimeters revealed doses between 1 and 2 mSv DDE. Four dosimeters registered over 2 mSv DDE, with a mean DDE of 3 mSv. Distances of less than 5 ft from the radiation source had the highest DDE dose. Maximum annual occupational DDE dose is conventionally 50 mSv. None of the dosimeters registered DDE doses over 4.31 mSv during the study period, supporting low radiation risk to providers in the trauma bay.