GGGuan-Yun Peng Guan-yun

Guan-Yun Peng Guan-yun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Guan-Yun Peng Guan-yun has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Detection of complex vascular system in bamboo node by X-ray μCT imaging technique

    by Guanyun Peng, Zehui Jiang, Xing’e Liu, Benhua Fei, Shumin Yang, Daochun Qin, Haiqing Ren, Yan Yu, Honglan Xie

    Bamboo is one of the world’s fastest growing plants. They reach a final height of 15–40 m during a period of 40–120 days. The full height is reached by intercalary growth of each node. However, it is very difficult to detect the complex vascular system in a bamboo node using traditional methods. X-ray computed microtomography (μCT) is a noninvasive novel approach to the three-dimensional (3D) visualization and quantification of biological structures. In the present article, μCT has been applied to provide insights into the internal structure of bamboo node, where three branches are connected. The picture obtained could hardly be obtained by any other means. The bamboo nodal characteristics of three transverse and axial sections are presented. The complex 3D network of vascular bundles has been directly obtained for the first time.


    • 1 March 2013
      • Vol. 33  (3) , 829-33

    [Investigation of characteristic microstructures of adhesive interface in wood/bamboo composite material by synchrotron radiation X-ray phase contrast microscopy].

    by Guan-Yun Peng, Yu-Rong Wang, Hai-Qing Ren, Shu-Min Yang, Hong-Xia Ma, Hong-Lan Xie, Biao Deng, Guo-Hao Du, Ti-Qiao Xiao

    Third-generation synchrotron radiation X-ray phase-contrast microscopy(XPCM)can be used for obtaining image with edge enhancement, and achieve the high contrast imaging of low-Z materials with the spatial coherence peculiarity of X-rays. In the present paper, the characteristic microstructures of adhesive at the interface and their penetration in wood/bamboo composite material were investigated systematically by XPCM at Shanghai Synchrotron Radiation Facility (SSRF). And the effect of several processing techniques was analyzed for the adhesive penetration in wood/bamboo materials. The results show that the synchrotron radiation XPCM is expected to be one of the important precision detection methods for wood-based panels.

  • Measuring the Density of Wood and Bamboo Using Computed Tomography

    by Guan-Yun Peng Guan-yun, Ze-Hui Jiang Ze-hui, Xing-E Liu Xing-e, Yu Yan, Shu-Min Yang Shu-min, Biao Deng Biao, Ti-Qiao Xiao Ti-qiao, Xiao-Huan Wang Xiao-huan

    CT is widespread non-destructive detection technique for wood materials, and the density measurement is a key role during this application. In the present report, the use of CT for air-dry density measurement of wood and bamboo is described. The authors found that there were marked linear correlations between air-dry density(0. 303 similar to 1. 061 g . cm(-3)) of 24 kinds of woods and their respective CT value, as well as 25 kinds of lignin materials (including 24 kinds of woods and 1 kind of bamboo) and the CT value, both with correlation coefficient of 0. 99, which belonged to the CT technological breakthrough for wood quantitative detection. These research results show that CT is an appropriate way to measure density for wood and bamboo, and would provide technical support for CT used in the field of wood science research and wood processing.