Makoto Abe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Makoto Abe has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Norihiro Sugita
Graduate School of Engineering, Tohoku University, Sendai, Japan
7 shared publications Akira Tanaka
Fac. of Symbiotic Syst. Sci., Fukushima Univ., Fukushima, Japan
4 shared publicationsMakoto Yoshizawa
Cyberscience Center, Tohoku Univ., Sendai, Japan
4 shared publications- Noriyasu Homma
Department of Radiological Imaging and Informatics, Tohoku University Graduate School of Medicine, Sendai, Japan
4 shared publications Shigeru Chiba
Sharp Corp., Chiba, Japan
4 shared publicationsShin-Ichi Nitta
Inst. of Dev., Tohoku Univ., Sendai, Japan
4 shared publications
Latest Publications
- 1 January 2014
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences
- Vol. E97.A (3) , 809-819
A Faster 1-D Phase-Only Correlation-Based Method for Estimations of Translations, Rotation and Scaling in Images
- 1 January 2014
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Fundamentals of Electronics, Communications and Computer Sciences
- Vol. E97.A (3) , 809-819
A Faster 1-D Phase-Only Correlation-Based Method for Estimations of Translations, Rotation and Scaling in Images
- Open Access
- 11 November 2013
- Published by Wiley in Electronics and Communications in Japan
- Vol. 96 (12) , 1-8
Improving the Detection Algorithm for Life-Threatening Arrhythmias: Implementation in Implantable Cardioverter-Defibrillators
- 11 November 2013
- Published by Wiley in Electronics and Communications in Japan
- Vol. 96 (12) , 1-8
Open AccessImproving the Detection Algorithm for Life-Threatening Arrhythmias: Implementation in Implantable Cardioverter-Defibrillators
- 23 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8316, 831639
Tumor image extraction from fluoroscopy for a markerless lung tumor motion tracking and prediction
We develop a markerless tumor motion tracking technique for accurate and safer image-guided radiation therapy (IGRT). The technique is implemented based on a new image model of the moving tumor and the background structure in an x-ray fluorocopic image sequence. By using the technique, the moving tumor image can be extracted from the sequential fluoroscopic images. The extraction from the fluoroscopy is obviously ill- posed, but we have suggested that it can be regularized into a well-posed problem by temporally accumulating constraints that must be satisfied by the extracted tumor image and the background. In this paper, the effect of the tumor extraction and motion of both the tumor and background in the image model is extensively studied on the tracking accuracy. The tracking accuracy of the proposed method with extraction of both the moving tumor and background was within $0.2$ mm of the spatial resolution for a phantom dataset. The accuracy within 1 mm can be clinically sufficient and is superior to the results by the previous method with extraction model of only the moving tumor and by a conventional method without extraction. Thus, the results clearly demonstrate the efficiency and usefulness of the proposed extraction model for the IGRT.- 23 February 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8316, 831639
Tumor image extraction from fluoroscopy for a markerless lung tumor motion tracking and prediction
We develop a markerless tumor motion tracking technique for accurate and safer image-guided radiation therapy (IGRT). The technique is implemented based on a new image model of the moving tumor and the background structure in an x-ray fluorocopic image sequence. By using the technique, the moving tumor image can be extracted from the sequential fluoroscopic images. The extraction from the fluoroscopy is obviously ill- posed, but we have suggested that it can be regularized into a well-posed problem by temporally accumulating constraints that must be satisfied by the extracted tumor image and the background. In this paper, the effect of the tumor extraction and motion of both the tumor and background in the image model is extensively studied on the tracking accuracy. The tracking accuracy of the proposed method with extraction of both the moving tumor and background was within $0.2$ mm of the spatial resolution for a phantom dataset. The accuracy within 1 mm can be clinically sufficient and is superior to the results by the previous method with extraction model of only the moving tumor and by a conventional method without extraction. Thus, the results clearly demonstrate the efficiency and usefulness of the proposed extraction model for the IGRT.- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2009 (1094687X) , 348-351
Estimation of blood pressure variability using independent component analysis of photoplethysmographic signal
The maximum cross-correlation coefficient rho max between blood pressure variability and heart rate variability, whose frequency components are limited to the Mayer wave-related band, is a useful index to evaluate the state of the autonomic nervous function related to baroreflex. However, measurement of continuous blood pressure with an expensive and bulky measuring device is required to calculate rho max . The present study has proposed an easier method for obtaining rho max with measurement of finger photoplethysmography (PPG). In the proposed method, independent components are extracted from feature variables specified by the PPG signal by using the independent component analysis (ICA), and then the most appropriate component is chosen out of them so that the rho max based on the component can fit its true value. The results from the experiment with a postural change performed in 17 healthy subjects suggested that the proposed method is available for estimating rho max by using the ICA to extract blood pressure information from the PPG signal.
- 1 September 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2009 (1094687X) , 348-351
Estimation of blood pressure variability using independent component analysis of photoplethysmographic signal
The maximum cross-correlation coefficient rho max between blood pressure variability and heart rate variability, whose frequency components are limited to the Mayer wave-related band, is a useful index to evaluate the state of the autonomic nervous function related to baroreflex. However, measurement of continuous blood pressure with an expensive and bulky measuring device is required to calculate rho max . The present study has proposed an easier method for obtaining rho max with measurement of finger photoplethysmography (PPG). In the proposed method, independent components are extracted from feature variables specified by the PPG signal by using the independent component analysis (ICA), and then the most appropriate component is chosen out of them so that the rho max based on the component can fit its true value. The results from the experiment with a postural change performed in 17 healthy subjects suggested that the proposed method is available for estimating rho max by using the ICA to extract blood pressure information from the PPG signal.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 4591-4594
A method for evaluating effects of visually-induced motion sickness using ICA for photoplethysmography
A human watching a swaying image displayed on a wide-field display or screen sometimes suffers from visually-induced motion sickness (VIMS) that causes symptoms related to the autonomic nervous system such as nausea, vomiting, and dizziness. Previous studies indicated that the maximum cross-correlation coefficient (ρ max ) between blood pressure and heart rate, whose frequency components were limited to the neighborhood of 0.1Hz, was a useful index to evaluate the effects of VIMS on humans. The present study proposed a new method for obtaining ρ max with measurement of neither continuous blood pressure nor ECG but using only finger photoplethysmography (PPG). In this study, heart rate was obtained from the foot-to-foot-interval of the PPG signal, and blood pressure-related and event-related pieces of information were obtained from the parameter extracted from using the independent component analysis. The adequacy of the proposed method was evaluated by two experiments with the Valsalva maneuver and with presentation of a swaying video image. The experimental results have shown that the proposed method could extract the independent component related to blood pressure and an event signal of Valsalva maneuver. In addition, the effects of VIMS could be estimated with the independent component.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 4591-4594
A method for evaluating effects of visually-induced motion sickness using ICA for photoplethysmography
A human watching a swaying image displayed on a wide-field display or screen sometimes suffers from visually-induced motion sickness (VIMS) that causes symptoms related to the autonomic nervous system such as nausea, vomiting, and dizziness. Previous studies indicated that the maximum cross-correlation coefficient (ρ max ) between blood pressure and heart rate, whose frequency components were limited to the neighborhood of 0.1Hz, was a useful index to evaluate the effects of VIMS on humans. The present study proposed a new method for obtaining ρ max with measurement of neither continuous blood pressure nor ECG but using only finger photoplethysmography (PPG). In this study, heart rate was obtained from the foot-to-foot-interval of the PPG signal, and blood pressure-related and event-related pieces of information were obtained from the parameter extracted from using the independent component analysis. The adequacy of the proposed method was evaluated by two experiments with the Valsalva maneuver and with presentation of a swaying video image. The experimental results have shown that the proposed method could extract the independent component related to blood pressure and an event signal of Valsalva maneuver. In addition, the effects of VIMS could be estimated with the independent component.
- Open Access
- 28 September 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 35
Evaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate
Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data.
- 28 September 2007
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 4 (1) , 35
Open AccessEvaluation of adaptation to visually induced motion sickness based on the maximum cross-correlation between pulse transmission time and heart rate
Computer graphics and virtual reality techniques are useful to develop automatic and effective rehabilitation systems. However, a kind of virtual environment including unstable visual images presented to wide field screen or a head mounted display tends to induce motion sickness. The motion sickness induced in using a rehabilitation system not only inhibits effective training but also may harm patients' health. There are few studies that have objectively evaluated the effects of the repetitive exposures to these stimuli on humans. The purpose of this study is to investigate the adaptation to visually induced motion sickness by physiological data.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 5501-5504
Estimation of Effects of Visually-Induced Motion Sickness Using Independent Component Analysis
To quantify the effect of visually-induced motion sickness on the autonomic nervous system, the authors previously proposed a new physiological index rhomax representing the maximum cross-correlation coefficient between blood pressure variability and heart rate variability whose frequency components are limited to the Mayer wave band. However, rhomax requires measurement of continuous blood pressure with an expensive and bulky measuring device. In the present study, an easier method for obtaining rhomax with measurement of neither continuous blood pressure nor ECG but using finger photoplethysmography (PPG) only has been developed. A blood pressure-related parameter was extracted from the PPG by using the independent component analysis. Two experiments in which subjects performed the Valsalva maneuver and then they watched a swaying video image were carried out to evaluate the adequacy of the proposed method. The experimental results have shown that the proposed method worked successfully as good as the conventional method. This means that the proposed method can contribute to increase in the number of subjects because multiple subjects can be used even in a single experiment.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2007 (1094687X) , 5501-5504
Estimation of Effects of Visually-Induced Motion Sickness Using Independent Component Analysis
To quantify the effect of visually-induced motion sickness on the autonomic nervous system, the authors previously proposed a new physiological index rhomax representing the maximum cross-correlation coefficient between blood pressure variability and heart rate variability whose frequency components are limited to the Mayer wave band. However, rhomax requires measurement of continuous blood pressure with an expensive and bulky measuring device. In the present study, an easier method for obtaining rhomax with measurement of neither continuous blood pressure nor ECG but using finger photoplethysmography (PPG) only has been developed. A blood pressure-related parameter was extracted from the PPG by using the independent component analysis. Two experiments in which subjects performed the Valsalva maneuver and then they watched a swaying video image were carried out to evaluate the adequacy of the proposed method. The experimental results have shown that the proposed method worked successfully as good as the conventional method. This means that the proposed method can contribute to increase in the number of subjects because multiple subjects can be used even in a single experiment.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2340-2343
Physiological Evaluation of Effects of Visually-Induced Motion Sickness Using Finger Photoplethysmography
The human watching moving images displayed on a wide-field display or screen sometimes suffers from the visually-induced motion sickness (VIMS) that induces symptoms related to the autonomic nervous system such as nausea, vomiting, and dizziness. The previous study indicated that the maximum cross-correlation coefficient (rhomax) between blood pressure and heart rate whose frequency components are limited to the neighborhood of 0.1 Hz is a useful index to evaluate the effects of the VIMS on humans [1]. The present study has proposed a new method for obtaining rhomax with measurement of neither continuous blood pressure nor ECG but using only finger photoplethysmography. The adequacy of the proposed method was evaluated on the basis of comparison with the conventional method. An experiment in which multiple subjects were simultaneously watching the same swaying video image was carried out. The experimental result has shown that the proposed method worked successfully as well as the conventional method
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2340-2343
Physiological Evaluation of Effects of Visually-Induced Motion Sickness Using Finger Photoplethysmography
The human watching moving images displayed on a wide-field display or screen sometimes suffers from the visually-induced motion sickness (VIMS) that induces symptoms related to the autonomic nervous system such as nausea, vomiting, and dizziness. The previous study indicated that the maximum cross-correlation coefficient (rhomax) between blood pressure and heart rate whose frequency components are limited to the neighborhood of 0.1 Hz is a useful index to evaluate the effects of the VIMS on humans [1]. The present study has proposed a new method for obtaining rhomax with measurement of neither continuous blood pressure nor ECG but using only finger photoplethysmography. The adequacy of the proposed method was evaluated on the basis of comparison with the conventional method. An experiment in which multiple subjects were simultaneously watching the same swaying video image was carried out. The experimental result has shown that the proposed method worked successfully as well as the conventional method