DHDaniela B. Husarik

Daniela B. Husarik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Daniela B. Husarik has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Model-based iterative reconstruction for improvement of low-contrast detectability in liver CT at reduced radiation dose: ex-vivo experience

    by D.B. Husarik, H. Alkadhi, G.D. Puippe, C.S. Reiner, N.C. Chuck, F. Morsbach, Z. Szucs-Farkas, S.T. Schindera


  • Open Access

    Combining automated attenuation-based tube voltage selection and iterative reconstruction: a liver phantom study

    by Daniela B. Husarik, Sebastian T. Schindera, Fabian Morsbach, Natalie Chuck, Burkhardt Seifert, Zsolt Szucs-Farkas, Hatem Alkadhi

    To determine the value of combined automated attenuation-based tube-potential selection and iterative reconstructions (IRs) for optimising computed tomography (CT) imaging of hypodense liver lesions.


  • Ligaments and Plicae of the Elbow: Normal MR Imaging Variability in 60 Asymptomatic Subjects

    by Daniela B. Husarik, Nadja Saupe, Christian W. A. Pfirrmann, Bernhard Jost, Juerg Hodler, Marco Zanetti

    To prospectively evaluate the normal variability of ligaments, plicae, and the posterior capitellum on conventional magnetic resonance (MR) images of the elbow in asymptomatic volunteers. The study was approved by the institutional ethics board, and informed consent was obtained from all subjects. MR imaging was performed at 1.5 T in 60 asymptomatic volunteers (30 women, 30 men; age range, 22-51 years; median age, 32.8 years) by using the following five pulse sequences: transverse T1-weighted spin-echo, sagittal T2-weighted fast spin-echo, coronal fast spin-echo short-inversion-time inversion recovery, transverse intermediate-weighted with fat saturation, and coronal three-dimensional water-excitation true fast imaging with steady-state precession. The visibility (completely visible over the entire course, partially visible, or not visible) and signal intensity characteristics (hypointense or hyperintense to muscle, homogeneous signal intensity vs striation) of the elbow ligaments and plicae were evaluated by three independent readers. The presence of pseudodefects at the posterior capitellum was determined. The dimensions of all structures were measured by two independent readers. The anterior ulnar collateral ligament (UCL) and radial collateral ligament (RCL) were visible over their entire course in all 60 subjects (100%). The posterior UCL, lateral UCL, and annular ligament (AL) were completely visible in 58 (97%), 51 (85%), and 59 (98%) of the 60 subjects, respectively, and partially visible in the remaining subjects. Increased signal intensity with fluid-sensitive sequences was found in the anterior UCL in nine of the 60 subjects (15%), posterior UCL in four subjects (7%), RCL in one subject (2%), lateral UCL in six subjects (10%), and AL in one subject (2%). The median thickness and 90th percentile were 2.5 and 3.5 mm, respectively, for the anterior UCL, 1.0 and 1.7 mm for the posterior UCL, 1.9 and 2.8 mm for the RCL, 2.3 and 3.8 mm for the lateral UCL, and 1.0 and 1.3 mm for the AL. A posterolateral plica (median dimension, 4.3 × 1.9 × 3.9 mm) was found in 59 of the 60 subjects (98%), whereas a posterior plica (median dimension, 1.8 × 1.4 mm) could be detected in only 20 (33%). A pseudodefect of the capitellum was noted in 51 of the 60 subjects (85%). The elbow ligaments and the posterolateral plica are consistently visible on conventional MR images of asymptomatic subjects. Most normal ligaments are thinner than 4 mm, and most plicae are thinner than 3 mm.


  • Elbow Nerves: MR Findings in 60 Asymptomatic Subjects—Normal Anatomy, Variants, and Pitfalls

    by Daniela B. Husarik, Nadja Saupe, Christian W. A. Pfirrmann, Bernhard Jost, Juerg Hodler, Marco Zanetti

    To prospectively evaluate the signal intensity (SI), course, and diameter of elbow nerves and to identify anatomic variants that are potentially associated with nerve compression syndromes on magnetic resonance (MR) images of asymptomatic elbows. This study was approved by the institutional review board. Informed consent was obtained from each volunteer. Sixty subjects with asymptomatic elbows (age range, 22.4-51.7 years; median age, 32.8 years) underwent MR imaging. Increased SI compared with surrounding muscles on fluid-sensitive MR images, anatomic course, anatomic nerve and muscle variants potentially associated with nerve compression syndromes, and qualitative changes in nerve diameters were evaluated. Quantitative data on the shortest and longest nerve diameters were obtained. Increased SI on fluid-sensitive MR images was seen in the ulnar nerve in 60% (36 of 60) of subjects but was never observed in the median and radial nerves. An atypical intermuscular course of the median nerve between the brachialis and pronator muscles was detected in 17% (10 of 60) of subjects. Ulnar nerve subluxation at the level of the cubital tunnel was seen in 2% (one of 60) of subjects; an anconeus epitrochlearis muscle, in 23% (14 of 60); and a hypertrophic leash of Henry, in 15% (nine of 60). Median nerve dimensions were 2.4 x 4.0 mm (range, 1.0-4.0 x 3.0-7.0 mm) for the ulnar nerve, 1.0 x 1.9 mm (range, 0.8-2.0 x 0.9-5.0 mm) for the radial nerve, and 3.0 x 5.4 mm (range, 1.0-5.0 x 3.0-9.0 mm) for the median nerve. Increased SI of the ulnar nerve on fluid-sensitive images (60%), an atypical intermuscular course of the median nerve (17%), and an anconeus epitrochlearis muscle (23%) are common MR findings in asymptomatic elbows.