Maarten Christian Niekel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maarten Christian Niekel has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Frank J. Wessels
Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, PO Box 85500, 3508 GA Utrecht, the Netherlands
1 shared publication - Hugo J. Kuijf
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
1 shared publication Jaap Stoker
1 shared publication- Josien P. W. Pluim
Eindhoven University of Technology
1 shared publication - Mariëlle J. A. Jansen
UMC Utrecht Utrecht University Image Sciences Institute P.O. Box 85500 Q02.445 3508 GA Utrecht the Netherlands
1 shared publication - Max A. Viergever
Image Sciences Institute, University Medical Center Utrecht, Utrecht, The Netherlands
1 shared publication
Latest Publications
- 15 October 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 6 (04) , 044003-10
Liver segmentation and metastases detection in MR images using convolutional neural networks
Primary tumors have a high likelihood of developing metastases in the liver, and early detection of these metastases is crucial for patient outcome. We propose a method based on convolutional neural networks to detect liver metastases. First, the liver is automatically segmented using the six phases of abdominal dynamic contrast-enhanced (DCE) MR images. Next, DCE-MR and diffusion weighted MR images are used for metastases detection within the liver mask. The liver segmentations have a median Dice similarity coefficient of 0.95 compared with manual annotations. The metastases detection method has a sensitivity of 99.8% with a median of two false positives per image. The combination of the two MR sequences in a dual pathway network is proven valuable for the detection of liver metastases. In conclusion, a high quality liver segmentation can be obtained in which we can successfully detect liver metastases.
- 15 October 2019
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 6 (04) , 044003-10
Liver segmentation and metastases detection in MR images using convolutional neural networks
Primary tumors have a high likelihood of developing metastases in the liver, and early detection of these metastases is crucial for patient outcome. We propose a method based on convolutional neural networks to detect liver metastases. First, the liver is automatically segmented using the six phases of abdominal dynamic contrast-enhanced (DCE) MR images. Next, DCE-MR and diffusion weighted MR images are used for metastases detection within the liver mask. The liver segmentations have a median Dice similarity coefficient of 0.95 compared with manual annotations. The metastases detection method has a sensitivity of 99.8% with a median of two false positives per image. The combination of the two MR sequences in a dual pathway network is proven valuable for the detection of liver metastases. In conclusion, a high quality liver segmentation can be obtained in which we can successfully detect liver metastases.
- Top Cited Papers
- 1 December 2010
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 257 (3) , 674-684
Diagnostic Imaging of Colorectal Liver Metastases with CT, MR Imaging, FDG PET, and/or FDG PET/CT: A Meta-Analysis of Prospective Studies Including Patients Who Have Not Previously Undergone Treatment
To obtain diagnostic performance values of computed tomography (CT), magnetic resonance (MR) imaging, fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET), and FDG PET/CT in the detection of colorectal liver metastases in patients who have not previously undergone therapy. A comprehensive search was performed for articles published from January 1990 to January 2010 that fulfilled the following criteria: a prospective study design was used; the study population included at least 10 patients; patients had histopathologically proved colorectal cancer; CT, MR imaging, FDG PET, or FDG PET/CT was performed for the detection of liver metastases; intraoperative findings or those from histopathologic examination or follow-up were used as the reference standard; and data for calculating sensitivity and specificity were included. Study design characteristics, patient characteristics, imaging features, reference tests, and 2 × 2 tables were recorded. Thirty-nine articles (3391 patients) were included. Variation existed in study design characteristics, patient descriptions, imaging features, and reference tests. The sensitivity estimates of CT, MR imaging, and FDG PET on a per-lesion basis were 74.4%, 80.3%, and 81.4%, respectively. On a per-patient basis, the sensitivities of CT, MR imaging, and FDG PET were 83.6%, 88.2%, and 94.1%, respectively. The per-patient sensitivity of CT was lower than that of FDG PET (P = .025). Specificity estimates were comparable. For lesions smaller than 10 mm, the sensitivity estimates for MR imaging were higher than those for CT. No differences were seen for lesions measuring at least 10 mm. The sensitivity of MR imaging increased significantly after January 2004. The use of liver-specific contrast material and multisection CT scanners did not provide improved results. Data about FDG PET/CT were too limited for comparisons with other modalities. MR imaging is the preferred first-line modality for evaluating colorectal liver metastases in patients who have not previously undergone therapy. FDG PET can be used as the second-line modality. The role of FDG PET/CT is not yet clear owing to the small number of studies. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100729/-/DC1.
- 1 December 2010
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 257 (3) , 674-684
Top Cited PapersDiagnostic Imaging of Colorectal Liver Metastases with CT, MR Imaging, FDG PET, and/or FDG PET/CT: A Meta-Analysis of Prospective Studies Including Patients Who Have Not Previously Undergone Treatment
To obtain diagnostic performance values of computed tomography (CT), magnetic resonance (MR) imaging, fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET), and FDG PET/CT in the detection of colorectal liver metastases in patients who have not previously undergone therapy. A comprehensive search was performed for articles published from January 1990 to January 2010 that fulfilled the following criteria: a prospective study design was used; the study population included at least 10 patients; patients had histopathologically proved colorectal cancer; CT, MR imaging, FDG PET, or FDG PET/CT was performed for the detection of liver metastases; intraoperative findings or those from histopathologic examination or follow-up were used as the reference standard; and data for calculating sensitivity and specificity were included. Study design characteristics, patient characteristics, imaging features, reference tests, and 2 × 2 tables were recorded. Thirty-nine articles (3391 patients) were included. Variation existed in study design characteristics, patient descriptions, imaging features, and reference tests. The sensitivity estimates of CT, MR imaging, and FDG PET on a per-lesion basis were 74.4%, 80.3%, and 81.4%, respectively. On a per-patient basis, the sensitivities of CT, MR imaging, and FDG PET were 83.6%, 88.2%, and 94.1%, respectively. The per-patient sensitivity of CT was lower than that of FDG PET (P = .025). Specificity estimates were comparable. For lesions smaller than 10 mm, the sensitivity estimates for MR imaging were higher than those for CT. No differences were seen for lesions measuring at least 10 mm. The sensitivity of MR imaging increased significantly after January 2004. The use of liver-specific contrast material and multisection CT scanners did not provide improved results. Data about FDG PET/CT were too limited for comparisons with other modalities. MR imaging is the preferred first-line modality for evaluating colorectal liver metastases in patients who have not previously undergone therapy. FDG PET can be used as the second-line modality. The role of FDG PET/CT is not yet clear owing to the small number of studies. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100729/-/DC1.