Gerard van Burken
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gerard van Burken has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Antonius F. W. van der Steen
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
3 shared publications - Johannes G. Bosch
Department of Cardiology, Erasmus MC University Medical Center, Rotterdam, The Netherlands
3 shared publications - Marijn van Stralen
Image Sciences Institute University Medical Center Utrecht Utrecht the Netherlands
2 shared publications - Nico de Jong
Biomedical Engineering, Department of Cardiology, Cardiovascular Institute, Erasmus MC, Rotterdam, The Netherlands
2 shared publications Alexander Haak
Department of Biomedical Engineering of the Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
1 shared publication- Arend F. L. Schinkel
Department of Cardiology, Thoraxcenter, Erasmus MC, Rotterdam, The Netherlands
1 shared publication
Latest Publications
- 8 April 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (7) , 1991-2000
Improved Segmentation of Multiple Cavities of the Heart in Wide-View 3-D Transesophageal Echocardiograms
- 8 April 2015
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 41 (7) , 1991-2000
Improved Segmentation of Multiple Cavities of the Heart in Wide-View 3-D Transesophageal Echocardiograms
- 14 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 19 (1) , 332-338
Carotid Intraplaque Neovascularization Quantification Software (CINQS)
Intraplaque neovascularization (IPN) is an important biomarker of atherosclerotic plaque vulnerability. As IPN can be detected by contrast enhanced ultrasound (CEUS), imaging-biomarkers derived from CEUS may allow early prediction of plaque vulnerability. To select the best quantitative imaging-biomarkers for prediction of plaque vulnerability, a systematic analysis of IPN with existing and new analysis algorithms is necessary. Currently available commercial contrast quantification tools are not applicable for quantitative analysis of carotid IPN due to substantial motion of the carotid artery, artifacts, and intermittent perfusion of plaques. We therefore developed a specialized software package called Carotid intraplaque neovascularization quantification software (CINQS). It was designed for effective and systematic comparison of sets of quantitative imaging biomarkers. CINQS includes several analysis algorithms for carotid IPN quantification and overcomes the limitations of current contrast quantification tools and existing carotid IPN quantification approaches. CINQS has a modular design which allows integrating new analysis tools. Wizard-like analysis tools and its graphical-user-interface facilitate its usage. In this paper, we describe the concept, analysis tools, and performance of CINQS and present analysis results of 45 plaques of 23 patients. The results in 45 plaques showed excellent agreement with visual IPN scores for two quantitative imaging-biomarkers (The area under the receiver operating characteristic curve was 0.92 and 0.93).
- 14 February 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 19 (1) , 332-338
Carotid Intraplaque Neovascularization Quantification Software (CINQS)
Intraplaque neovascularization (IPN) is an important biomarker of atherosclerotic plaque vulnerability. As IPN can be detected by contrast enhanced ultrasound (CEUS), imaging-biomarkers derived from CEUS may allow early prediction of plaque vulnerability. To select the best quantitative imaging-biomarkers for prediction of plaque vulnerability, a systematic analysis of IPN with existing and new analysis algorithms is necessary. Currently available commercial contrast quantification tools are not applicable for quantitative analysis of carotid IPN due to substantial motion of the carotid artery, artifacts, and intermittent perfusion of plaques. We therefore developed a specialized software package called Carotid intraplaque neovascularization quantification software (CINQS). It was designed for effective and systematic comparison of sets of quantitative imaging biomarkers. CINQS includes several analysis algorithms for carotid IPN quantification and overcomes the limitations of current contrast quantification tools and existing carotid IPN quantification approaches. CINQS has a modular design which allows integrating new analysis tools. Wizard-like analysis tools and its graphical-user-interface facilitate its usage. In this paper, we describe the concept, analysis tools, and performance of CINQS and present analysis results of 45 plaques of 23 patients. The results in 45 plaques showed excellent agreement with visual IPN scores for two quantitative imaging-biomarkers (The area under the receiver operating characteristic curve was 0.92 and 0.93).
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6144, 614418
Registration of 2D cardiac images to real-time 3D ultrasound volumes for 3D stress echocardiography
Three-dimensional (3D) stress echocardiography is a novel technique for diagnosing cardiac dysfunction, by comparing wall motion of the left ventricle under different stages of stress. For quantitative comparison of this motion, it is essential to register the ultrasound data. We propose an intensity based rigid registration method to retrieve two-dimensional (2D) four-chamber (4C), two-chamber, and short-axis planes from the 3D data set acquired in the stress stage, using manually selected 2D planes in the rest stage as reference. The algorithm uses the Nelder-Mead simplex optimization to find the optimal transformation of one uniform scaling, three rotation, and three translation parameters. We compared registration using the SAD, SSD, and NCC metrics, performed on four resolution levels of a Gaussian pyramid. The registration's effectiveness was assessed by comparing the 3D positions of the registered apex and mitral valve midpoints and 4C direction with the manually selected results. The registration was tested on data from 20 patients. Best results were found using the NCC metric on data downsampled with factor two: mean registration errors were 8.1mm, 5.4mm, and 8.0° in the apex position, mitral valve position, and 4C direction respectively. The errors were close to the interobserver (7.1mm, 3.8mm, 7.4°) and intraobserver variability (5.2mm, 3.3mm, 7.0°), and better than the error before registration (9.4mm, 9.0mm, 9.9°). We demonstrated that the registration algorithm visually and quantitatively improves the alignment of rest and stress data sets, performing similar to manual alignment. This will improve automated analysis in 3D stress echocardiography.
- 2 March 2006
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6144, 614418
Registration of 2D cardiac images to real-time 3D ultrasound volumes for 3D stress echocardiography
Three-dimensional (3D) stress echocardiography is a novel technique for diagnosing cardiac dysfunction, by comparing wall motion of the left ventricle under different stages of stress. For quantitative comparison of this motion, it is essential to register the ultrasound data. We propose an intensity based rigid registration method to retrieve two-dimensional (2D) four-chamber (4C), two-chamber, and short-axis planes from the 3D data set acquired in the stress stage, using manually selected 2D planes in the rest stage as reference. The algorithm uses the Nelder-Mead simplex optimization to find the optimal transformation of one uniform scaling, three rotation, and three translation parameters. We compared registration using the SAD, SSD, and NCC metrics, performed on four resolution levels of a Gaussian pyramid. The registration's effectiveness was assessed by comparing the 3D positions of the registered apex and mitral valve midpoints and 4C direction with the manually selected results. The registration was tested on data from 20 patients. Best results were found using the NCC metric on data downsampled with factor two: mean registration errors were 8.1mm, 5.4mm, and 8.0° in the apex position, mitral valve position, and 4C direction respectively. The errors were close to the interobserver (7.1mm, 3.8mm, 7.4°) and intraobserver variability (5.2mm, 3.3mm, 7.0°), and better than the error before registration (9.4mm, 9.0mm, 9.9°). We demonstrated that the registration algorithm visually and quantitatively improves the alignment of rest and stress data sets, performing similar to manual alignment. This will improve automated analysis in 3D stress echocardiography.