Minia Hellan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Minia Hellan has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Alessio Pigazzi
University of California
2 shared publicationsJames Ouellette
Division of Surgical Oncology, Wright State University, Dayton, OH, USA
2 shared publications- James Ouellette
Boonshoft School of Medicine, Wright State University
2 shared publications Jorge A. Lagares-Garcia
Roper St. Francis Hospital
2 shared publicationsJustin P. Fox
Wright State University Department of Surgery Dayton OH USA
2 shared publicationsRebecca M. Tuttle
2 shared publications
Latest Publications
- 25 December 2019
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 16 (2) , e2073
Totally robotic vs hybrid abdominoperineal resection: A retrospective multicenter analysis
Introduction: Laparoscopic abdominoperineal resection (APR) for low rectal cancers is technically demanding. Robotic assistance may be of help and can be hybrid (HAPR) or totally robotic (RAPR). The present study describes outcomes of robotic APR and compares both approaches.Material and methods: A multicentric retrospective analysis of rectal cancer patients undergoing either HAPR or RAPR was conducted. Patients' demographics, surgeons' experience, oncologic results, and intraoperative and postoperative outcomes were collected.Results: One hundred twenty‐five patients were included, 48 in HAPR group and 77 in RAPR group. Demographics and comorbidities were comparable. Operative time was reduced in RAPR group (266.9 ± 107.8 min vs 318.9 ± 75.1 min, P = .001). RAPR patients were discharged home more frequently (91.18% vs 66.67%, P = .001), and experienced fewer parastomal hernias (3.71% vs 9.86%, P = .001).Conclusion: RAPR is safe and feasible with appropriate oncologic outcomes. Totally robotic approach reduces operative time and may improve functional outcomes.
- 25 December 2019
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 16 (2) , e2073
Totally robotic vs hybrid abdominoperineal resection: A retrospective multicenter analysis
Introduction: Laparoscopic abdominoperineal resection (APR) for low rectal cancers is technically demanding. Robotic assistance may be of help and can be hybrid (HAPR) or totally robotic (RAPR). The present study describes outcomes of robotic APR and compares both approaches.Material and methods: A multicentric retrospective analysis of rectal cancer patients undergoing either HAPR or RAPR was conducted. Patients' demographics, surgeons' experience, oncologic results, and intraoperative and postoperative outcomes were collected.Results: One hundred twenty‐five patients were included, 48 in HAPR group and 77 in RAPR group. Demographics and comorbidities were comparable. Operative time was reduced in RAPR group (266.9 ± 107.8 min vs 318.9 ± 75.1 min, P = .001). RAPR patients were discharged home more frequently (91.18% vs 66.67%, P = .001), and experienced fewer parastomal hernias (3.71% vs 9.86%, P = .001).Conclusion: RAPR is safe and feasible with appropriate oncologic outcomes. Totally robotic approach reduces operative time and may improve functional outcomes.
- Open Access
- 1 January 2017
- Published by Open Access Text Pvt, Ltd. in Liver and Pancreatic Sciences
- Vol. 2 (1)
Irreversible electroporation of locally recurrent pancreatic cancer with 5-year survival
- 1 January 2017
- Published by Open Access Text Pvt, Ltd. in Liver and Pancreatic Sciences
- Vol. 2 (1)
Open AccessIrreversible electroporation of locally recurrent pancreatic cancer with 5-year survival
- 20 July 2016
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 13 (3) , e1764
Novel technique of robotic extralevator abdominoperineal resection with gracilis flap closure
Background: The purpose of this paper is to introduce a robotic assisted approach to extralevator abdominoperineal excision in the modified Lloyd‐Davis position with reconstruction of the perineum using pedicled gracilis flaps, and to discuss outcomes in a cohort of six patients.Methods: Data was collected by chart review on six patients who underwent extralevator excision with gracilis flap reconstruction from 10/2013 to 06/2015. Technical details, operative data, oncologic outcomes, and wound healing complications were evaluated.Results: There were no instances of intraoperative perforation or positive circumferential resection margin, and one case of locoregional recurrence. Two patients experienced flap venous congestion and one patient developed a perineal abscess. All patients went on to complete healing.Conclusions: The combination of a minimally invasive robotic assisted extralevator abdominoperineal excision performed in the modified Lloyd‐Davis position with reconstruction of the perineum with pedicled gracilis flaps has excellent oncologic outcomes and acceptable wound healing complications. Copyright © 2016 John Wiley & Sons, Ltd. StartCopTextCopyright © 2016 John Wiley & Sons, Ltd.
- 20 July 2016
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 13 (3) , e1764
Novel technique of robotic extralevator abdominoperineal resection with gracilis flap closure
Background: The purpose of this paper is to introduce a robotic assisted approach to extralevator abdominoperineal excision in the modified Lloyd‐Davis position with reconstruction of the perineum using pedicled gracilis flaps, and to discuss outcomes in a cohort of six patients.Methods: Data was collected by chart review on six patients who underwent extralevator excision with gracilis flap reconstruction from 10/2013 to 06/2015. Technical details, operative data, oncologic outcomes, and wound healing complications were evaluated.Results: There were no instances of intraoperative perforation or positive circumferential resection margin, and one case of locoregional recurrence. Two patients experienced flap venous congestion and one patient developed a perineal abscess. All patients went on to complete healing.Conclusions: The combination of a minimally invasive robotic assisted extralevator abdominoperineal excision performed in the modified Lloyd‐Davis position with reconstruction of the perineum with pedicled gracilis flaps has excellent oncologic outcomes and acceptable wound healing complications. Copyright © 2016 John Wiley & Sons, Ltd. StartCopTextCopyright © 2016 John Wiley & Sons, Ltd.
- 9 December 2014
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 22 (7) , 2151-2158
Robotic Rectal Cancer Resection: A Retrospective Multicenter Analysis
Conventional laparoscopy has been applied to colorectal resections for more than 2 decades. However, laparoscopic rectal resection is technically demanding, especially when performing a tumor-specific mesorectal excision in a difficult pelvis. Robotic surgery is uniquely designed to overcome most of these technical limitations. The aim of this study was to confirm the feasibility of robotic rectal cancer surgery in a large multicenter study. Retrospective data of 425 patients who underwent robotic tumor-specific mesorectal excision for rectal lesions at seven institutions were collected. Outcome data were analyzed for the overall cohort and were stratified according to obese versus non-obese and low versus ultra-low resection patients. Mean age was 60.9 years, and 57.9 % of patients were male. Overall, 51.3 % of patients underwent neoadjuvant therapy, while operative time was 240 min, mean blood loss 119 ml, and intraoperative complication rate 4.5 %. Mean number of lymph nodes was 17.4, with a positive circumferential margin rate of 0.9 %. Conversion rate to open was 5.9 %, anastomotic leak rate was 8.7 %, with a mean length of stay of 5.7 days. Operative times were significantly longer and re-admission rate higher for the obese population, with all other parameters comparable. Ultra-low resections also had longer operative times. Robotic-assisted minimally invasive surgery for the treatment of rectal cancer is safe and can be performed according to current oncologic principles. BMI seems to play a minor role in influencing outcomes. Thus, robotics might be an excellent treatment option for the challenging patient undergoing resection for rectal cancer.
- 9 December 2014
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 22 (7) , 2151-2158
Robotic Rectal Cancer Resection: A Retrospective Multicenter Analysis
Conventional laparoscopy has been applied to colorectal resections for more than 2 decades. However, laparoscopic rectal resection is technically demanding, especially when performing a tumor-specific mesorectal excision in a difficult pelvis. Robotic surgery is uniquely designed to overcome most of these technical limitations. The aim of this study was to confirm the feasibility of robotic rectal cancer surgery in a large multicenter study. Retrospective data of 425 patients who underwent robotic tumor-specific mesorectal excision for rectal lesions at seven institutions were collected. Outcome data were analyzed for the overall cohort and were stratified according to obese versus non-obese and low versus ultra-low resection patients. Mean age was 60.9 years, and 57.9 % of patients were male. Overall, 51.3 % of patients underwent neoadjuvant therapy, while operative time was 240 min, mean blood loss 119 ml, and intraoperative complication rate 4.5 %. Mean number of lymph nodes was 17.4, with a positive circumferential margin rate of 0.9 %. Conversion rate to open was 5.9 %, anastomotic leak rate was 8.7 %, with a mean length of stay of 5.7 days. Operative times were significantly longer and re-admission rate higher for the obese population, with all other parameters comparable. Ultra-low resections also had longer operative times. Robotic-assisted minimally invasive surgery for the treatment of rectal cancer is safe and can be performed according to current oncologic principles. BMI seems to play a minor role in influencing outcomes. Thus, robotics might be an excellent treatment option for the challenging patient undergoing resection for rectal cancer.
- 3 January 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (5) , 1695-1702
The influence of fluorescence imaging on the location of bowel transection during robotic left-sided colorectal surgery
Hypoperfusion is an important risk factor for anastomotic leakage in colorectal surgery. This study was designed to evaluate the impact of fluorescence imaging on visualization of perfusion and subsequent change of transection line during left-sided robotic colorectal resections. Patients scheduled for robotic left-sided colon or rectal resections were enrolled in this prospective, multicenter study. Resections were performed as per each surgeon’s preference. After complete colorectal mobilization, ligation of blood vessels, and distal transection of the bowel, the mesocolon was completely divided to the planned proximal or distal transection line, which was marked in white light. Indocyanine green was injected intravenously and the transection location(s) and/or distal rectal stump, if applicable, were re-assessed in fluorescent imaging mode. Imaging information, perioperative, and early postoperative outcomes were recorded. An independent video review of the surgeries was performed. Data for 40 patients (20 female/20 male) with a mean age of 63.9 years and a mean body mass index of 27.6 kg/m2 were analyzed. Fluorescence imaging resulted in a change of the proximal transection location in 40 % (16/40) of patients. There was one change in the distal transection location in a patient with benign disease. The use of fluorescence imaging took an average of 5.1 min of the mean overall operative room time of 232 min. Two patients (5 %) with a change in transection line developed an anastomotic leak at postoperative days 15 and 40. Fluorescence imaging provides additional information during determination of transection location in left-sided colorectal procedures. This results in a significant change of transection location, particularly at the proximal transection site. Further research needs to be conducted with larger patient cohorts and in comparative design to determine actual effect on anastomotic leak rate.
- 3 January 2014
- Published by Springer Nature in Surgical Endoscopy
- Vol. 28 (5) , 1695-1702
The influence of fluorescence imaging on the location of bowel transection during robotic left-sided colorectal surgery
Hypoperfusion is an important risk factor for anastomotic leakage in colorectal surgery. This study was designed to evaluate the impact of fluorescence imaging on visualization of perfusion and subsequent change of transection line during left-sided robotic colorectal resections. Patients scheduled for robotic left-sided colon or rectal resections were enrolled in this prospective, multicenter study. Resections were performed as per each surgeon’s preference. After complete colorectal mobilization, ligation of blood vessels, and distal transection of the bowel, the mesocolon was completely divided to the planned proximal or distal transection line, which was marked in white light. Indocyanine green was injected intravenously and the transection location(s) and/or distal rectal stump, if applicable, were re-assessed in fluorescent imaging mode. Imaging information, perioperative, and early postoperative outcomes were recorded. An independent video review of the surgeries was performed. Data for 40 patients (20 female/20 male) with a mean age of 63.9 years and a mean body mass index of 27.6 kg/m2 were analyzed. Fluorescence imaging resulted in a change of the proximal transection location in 40 % (16/40) of patients. There was one change in the distal transection location in a patient with benign disease. The use of fluorescence imaging took an average of 5.1 min of the mean overall operative room time of 232 min. Two patients (5 %) with a change in transection line developed an anastomotic leak at postoperative days 15 and 40. Fluorescence imaging provides additional information during determination of transection location in left-sided colorectal procedures. This results in a significant change of transection location, particularly at the proximal transection site. Further research needs to be conducted with larger patient cohorts and in comparative design to determine actual effect on anastomotic leak rate.
- 31 May 2010
- Published by Elsevier in Gastroenterology
- Vol. 138 (5) , -872-872
M1638 Open Versus Laparoscopic Liver Resection: Looking Beyond the Immediate Post-Operative Period
- 31 May 2010
- Published by Elsevier in Gastroenterology
- Vol. 138 (5) , -872-872
M1638 Open Versus Laparoscopic Liver Resection: Looking Beyond the Immediate Post-Operative Period