JDJames A. D'Arcy

James A. D'Arcy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James A. D'Arcy has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Primary Human Breast Adenocarcinoma: Imaging and Histologic Correlates of Intrinsic Susceptibility-weighted MR Imaging before and during Chemotherapy

    by Sonia P. Li, N. Jane Taylor, Andreas Makris, Mei-Lin W. Ah-See, Mark J. Beresford, J. James Stirling, James A. D’arcy, David J. Collins, Anwar R. Padhani

    To investigate the histopathologic and dynamic magnetic resonance (MR) imaging correlates of intrinsic susceptibility-weighted (ISW) MR imaging in patients with primary human breast adenocarcinoma and to assess the relationship between baseline transverse relaxation rate (R2*) and T2* relaxivity change (ΔR2*) and the response to neoadjuvant chemotherapy (NAC). Institutional ethics approval and informed consent were obtained. Between September 2001 and January 2008, 83 women (median age, 46 years; age range, 26-72 years) with breast cancer were recruited to undergo dynamic contrast medium-enhanced (DCE), dynamic susceptibility contrast-enhanced (DSC), and ISW MR imaging before and after two cycles of NAC. After excluding necrotic, infiltrating, and invasive lobular carcinomas, 31 patients were available for baseline assessment and 27 were available for response assessment. Transfer constant, leakage space, rate constant, initial area under the gadolinium concentration-time curve at 60 seconds, relative blood volume (rBV), relative blood flow (rBF), and R2* were calculated. Relationships between baseline R2* and histopathologic variables (tumor grade, estrogen receptor status, progesterone receptor status, human epidermal growth factor 2 status), tumor size, and dynamic MR imaging parameters were sought. Baseline adenocarcinoma R2* (n = 31) and ΔR2* (n = 27) were correlated with final pathologic response. Inverse correlations between baseline R2* and rBV (ρ = -0.48, P = .013) and rBF (ρ = -0.44, P = .024) were found, but not after NAC. No relationships were observed between baseline R2* and other kinetic imaging parameters, histopathologic characteristics, or tumor size (P > .05). Baseline R2* values were lower in tumors than in normal breast tissue (31.8 sec(-1) vs 36.2 sec(-1), P = .017) but not after NAC. Increases in R2* were observed after treatment (31.1 sec(-1) vs 34.8 sec(-1), P = .006), with larger increases correlating with pathologic response. ΔR2* was not as effective as DCE or DSC MR imaging parameters in the prediction of response. R2* is influenced by blood volume in untreated breast adenocarcinomas. Increases in R2* after two cycles of NAC correlate with pathologic response. Therapy-induced uncoupling of the relationship between R2* and rBV and rBF is consistent with responding tumors becoming hypoxic early during treatment. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10100421/-/DC1.


  • Inter- and intraobserver variability in the evaluation of dynamic breast cancer MRI

    by Mark J. Beresford, Anwar R. Padhani, N. Jane Taylor, Mei-Lin Ah-See, J. James Stirling, Andreas Makris, James A. D'Arcy, David J. Collins


  • Magnetic Resonance Imaging Workbench: Analysis and Visualization of Dynamic Contrast-enhanced MR Imaging Data

    by James A. D’aRcy, David J. Collins, Anwar R. Padhani, Simon Walker-Samuel, John Suckling, Martin O. Leach

    Magnetic Resonance Imaging Workbench (MRIW) allows analysis of T1- and T2*-weighted dynamic contrast-enhanced magnetic resonance imaging data sets to extract tissue permeability and perfusion characteristics by using standard pharmacokinetic models. Parametric maps are calculated from individual pixel enhancement curves in regions of interest (ROIs) and displayed as color overlays on the anatomic images. User-defined ROIs can be saved to ensure consistency of later reanalysis. Individual parametric maps are visualized together with user-selected parameter time-series plots. The following selections are available: overall ROI enhancement curve and fit, histogram, and individual pixel enhancement curve and fit. Summary data (transfer constant, leakage space, rate constant, integrated area under the gadolinium curve after 60 seconds, relative blood volume, relative blood flow, and mean transit time) may be exported to permanent storage along with per-pixel results for statistical analysis. Numerical values for parameters are displayed below the plot for easy reference. The dynamic range of plots and parametric map overlays is interactively adjustable. Viewing individual enhancement curves and parametric maps allows radiologists to investigate the heterogeneity of contrast agent kinetics for lesion characterization and to scrutinize serial changes in response to therapy. MRIW is written in IDL, enabling it to be used on a variety of computer systems.


  • Open Access

    Applications of sliding window reconstruction with cartesian sampling for dynamic contrast enhanced MRI

    by J. A. D'ARcy, D. J. Collins, I. J. Rowland, A. R. Padhani, M. O. Leach

    Applications of dynamic contrast enhanced MR imaging are increasing and require both high spatial resolution and high temporal resolution. Perfusion studies using susceptibility contrast in particular require very high temporal resolution. The sliding window reconstruction is a technique for increasing temporal resolution. It has previously been applied to radial and spiral sampling, but these schemes require extensive correction and interpolation during image reconstruction. Fourier raw data can be reconstructed simply and quickly using the fast fourier transform (FFT). This paper presents a new Fourier‐based sampling scheme and sliding window reconstruction that facilitates fast scanning without needing correction or interpolation. This technique can be used on virtually any MR scanner since it requires no specialized hardware. It is implemented here as a dual gradient echo sequence providing simultaneous T1‐ and T2*‐weighted images with a time resolution of 1.1 s. Copyright © 2002 John Wiley & Sons, Ltd.