Grant M. Stevens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Grant M. Stevens has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Norbert J. Pelc
2 shared publications- Bruce L. Daniel
Department of Radiology, Lucas MRS/I Center, Stanford University, California 94305-5488, USA
1 shared publication Christopher F. Beaulieu
1 shared publicationDavid L. Ergun
Lunar Corporation, Madison, Wisconsin
1 shared publication- Debra Masako Ikeda
Department of Radiology, Stanford University School of Medicine, Stanford, California
1 shared publication John A. Rowlands
Department of Medical Biophysics, University of Toronto, and Sunnybrook Health Sciences Center
1 shared publication
Latest Publications
- 1 August 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (2) , 569-575
Circular Tomosynthesis: Potential in Imaging of Breast and Upper Cervical Spine—Preliminary Phantom and in Vitro Study
Phantom and in vitro studies were performed to evaluate the potential application of digital circular tomosynthesis in imaging of the breast and upper cervical spine. A prototype volumetric x-ray system was used to image a mammographic phantom, a fresh mastectomy specimen, and a head phantom containing the upper cervical spine. Results show that breast tissue visualization is improved by the ability to produce sectional images that blur overlying structures and yield three-dimensional information about calcification clusters. In upper cervical spine imaging, digital circular tomosynthesis effectively blurs overlying jaw and skull structures so that C1 and C2 can be visualized in a standard anteroposterior view.
- 1 August 2003
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 228 (2) , 569-575
Circular Tomosynthesis: Potential in Imaging of Breast and Upper Cervical Spine—Preliminary Phantom and in Vitro Study
Phantom and in vitro studies were performed to evaluate the potential application of digital circular tomosynthesis in imaging of the breast and upper cervical spine. A prototype volumetric x-ray system was used to image a mammographic phantom, a fresh mastectomy specimen, and a head phantom containing the upper cervical spine. Results show that breast tissue visualization is improved by the ability to produce sectional images that blur overlying structures and yield three-dimensional information about calcification clusters. In upper cervical spine imaging, digital circular tomosynthesis effectively blurs overlying jaw and skull structures so that C1 and C2 can be visualized in a standard anteroposterior view.
- Open Access
- 16 January 2001
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 13 (2) , 294-300
A truly hybrid interventional MR/X‐ray system: Feasibility demonstration
- 16 January 2001
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 13 (2) , 294-300
Open AccessA truly hybrid interventional MR/X‐ray system: Feasibility demonstration
- 5 May 2000
- Published by Wiley in Medical Physics
- Vol. 27 (5) , 1174-1184
Depth-segmented detector for x-ray absorptiometry
A new energy-dependent multi-cell detector, which is a generalization of the conventional front-back detector, was studied using computer simulations. The noise performance of the detector for bone quantitation was examined in comparison to an ideal energy discriminating detector, and front-back detectors with and without inter-detector filters. The front-back detectors were optimized for a reference object composed of water and bone, and then compared to the new detector over a range of object compositions. In this paper, precision in calculated bone thickness is used as the criterion for evaluating detector performance. Simulations show that the segmented detector always performs better than the front-back detector without an inter-detector filter. It outperforms the detector incorporating a filter by an amount that depends on the heterogeneity of the x-ray spectrum. In addition, for single component radiographic images, this multi-cell detector retains information which is lost in the front-back detector with a filter layer.
- 5 May 2000
- Published by Wiley in Medical Physics
- Vol. 27 (5) , 1174-1184
Depth-segmented detector for x-ray absorptiometry
A new energy-dependent multi-cell detector, which is a generalization of the conventional front-back detector, was studied using computer simulations. The noise performance of the detector for bone quantitation was examined in comparison to an ideal energy discriminating detector, and front-back detectors with and without inter-detector filters. The front-back detectors were optimized for a reference object composed of water and bone, and then compared to the new detector over a range of object compositions. In this paper, precision in calculated bone thickness is used as the criterion for evaluating detector performance. Simulations show that the segmented detector always performs better than the front-back detector without an inter-detector filter. It outperforms the detector incorporating a filter by an amount that depends on the heterogeneity of the x-ray spectrum. In addition, for single component radiographic images, this multi-cell detector retains information which is lost in the front-back detector with a filter layer.