Peter N. Burns
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Peter N. Burns has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Hyun-Jung Jang
Medical Imaging, University of Toronto, Toronto, ON, Canada
2 shared publications - Tae Kyoung Kim
Department of Medical Imaging, University of Toronto, Toronto, Canada
2 shared publications - An Tang
Department of Radiology, Centre Hospitalier de l’Université de Montréal (CHUM), Montreal, Canada
1 shared publication Bina Lanka
Department of Medical Imaging, Toronto General Hospital, University of Toronto, Toronto, Ontario, Canada
1 shared publicationCharles J. Pavlin
Mount Sinai Hospital, Toronto, Ontario, Canada (C.J.P.)
1 shared publicationDerek Muradali
1 shared publication
Latest Publications
- 31 December 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (12) , 1963-1969
Does Hepatic Vein Transit Time Performed with Contrast-Enhanced Ultrasound Predict the Severity of Hepatic Fibrosis?
- 31 December 2011
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 37 (12) , 1963-1969
Does Hepatic Vein Transit Time Performed with Contrast-Enhanced Ultrasound Predict the Severity of Hepatic Fibrosis?
- 1 December 2007
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 26 (12) , 1703-1714
Impact of Contrast-Enhanced Ultrasonography in a Tertiary Clinical Practice
- 1 December 2007
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 26 (12) , 1703-1714
Impact of Contrast-Enhanced Ultrasonography in a Tertiary Clinical Practice
- 1 June 2007
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 26 (6) , 731-738
Insonation of the Eye in the Presence of Microbubbles
Objective The purpose of this study was to investigate the presence and duration of vascular permeability changes induced by the combination of ultrasound and an intravascular microbubble contrast a...
- 1 June 2007
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 26 (6) , 731-738
Insonation of the Eye in the Presence of Microbubbles
Objective The purpose of this study was to investigate the presence and duration of vascular permeability changes induced by the combination of ultrasound and an intravascular microbubble contrast a...
- 1 January 2007
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (1) , 162-174
Focal Liver Masses: Enhancement Patterns on Contrast-enhanced Images—Concordance of US Scans with CT Scans and MR Images
To assess prospectively the concordance of enhancement patterns of focal liver masses on contrast material-enhanced ultrasonographic (US) scans with patterns on contrast-enhanced computed tomographic (CT) scans or magnetic resonance (MR) images. This study was approved by the institutional review board; patients gave informed consent. Contrast-enhanced US and contrast-enhanced CT or MR imaging were performed in 135 patients (62 men, 73 women; mean age, 51 years) with 144 confirmed liver masses. Masses included 49 hepatocellular carcinomas, 13 metastases, 30 hemangiomas, 41 lesions of focal nodular hyperplasia, and 11 others. Randomized image sets from each modality were shown independently to three blinded readers, who answered identical questions about enhancement of the lesion and liver in the arterial and portal venous phases and changes with time. Concordance for modalities was calculated from answers of readers and consensus answers between readers, with 95% confidence intervals (CIs). The kappa values were calculated for interreader agreement. Features of arterial phase enhancement showed concordance of more than 76% for modalities. The highest concordance of 92% (132 of 144), with 95% CI of 86% and 95% (kappa>0.84), was for the presence of peripheral pools and centripetal progression. Concordance in the portal venous phase was lower, with agreement for predominant enhancement of the lesion in 61% (86 of 142), with 95% CI of 52% and 68% (kappa>0.83). Portal venous phase washout occurred in 75% (106 of 142), with 95% CI of 67% and 81% (kappa>0.81). The majority of discordances were for malignancies for which only US depicted no sustained enhancement in the portal venous phase. US shows high concordance with CT or MR imaging, especially for the arterial phase. Discordance in the portal venous phase may reflect the tendency of CT and MR contrast agents, unlike microbubbles, to diffuse into interstitium.
- 1 January 2007
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 242 (1) , 162-174
Focal Liver Masses: Enhancement Patterns on Contrast-enhanced Images—Concordance of US Scans with CT Scans and MR Images
To assess prospectively the concordance of enhancement patterns of focal liver masses on contrast material-enhanced ultrasonographic (US) scans with patterns on contrast-enhanced computed tomographic (CT) scans or magnetic resonance (MR) images. This study was approved by the institutional review board; patients gave informed consent. Contrast-enhanced US and contrast-enhanced CT or MR imaging were performed in 135 patients (62 men, 73 women; mean age, 51 years) with 144 confirmed liver masses. Masses included 49 hepatocellular carcinomas, 13 metastases, 30 hemangiomas, 41 lesions of focal nodular hyperplasia, and 11 others. Randomized image sets from each modality were shown independently to three blinded readers, who answered identical questions about enhancement of the lesion and liver in the arterial and portal venous phases and changes with time. Concordance for modalities was calculated from answers of readers and consensus answers between readers, with 95% confidence intervals (CIs). The kappa values were calculated for interreader agreement. Features of arterial phase enhancement showed concordance of more than 76% for modalities. The highest concordance of 92% (132 of 144), with 95% CI of 86% and 95% (kappa>0.84), was for the presence of peripheral pools and centripetal progression. Concordance in the portal venous phase was lower, with agreement for predominant enhancement of the lesion in 61% (86 of 142), with 95% CI of 52% and 68% (kappa>0.83). Portal venous phase washout occurred in 75% (106 of 142), with 95% CI of 67% and 81% (kappa>0.81). The majority of discordances were for malignancies for which only US depicted no sustained enhancement in the portal venous phase. US shows high concordance with CT or MR imaging, especially for the arterial phase. Discordance in the portal venous phase may reflect the tendency of CT and MR contrast agents, unlike microbubbles, to diffuse into interstitium.
- 1 March 2006
- Vol. 22 (1) , 5-13
Microbubble contrast for radiological imaging: 1. Principles.
Microbubble contrast for ultrasound imaging in radiology has finally come of age, adding entirely new capabilities to real time imaging. Following a bolus injection into a peripheral vein of as little as 0.1mL of an aqueous suspension, contrast specific imaging modes show parenchymal and lesional perfusion in real time in the major organs of the abdomen and pelvis as well as breast, thyroid and prostate. These new imaging modes exploit the unique interaction between ultrasound and microbubbles, which gives rise to nonlinear echoes that are readily distinguishable from those of tissue. Furthermore, microbubbles can be deliberately disrupted by the ultrasound imaging field. The rate at which fresh bubbles then replenish the scanplane can be metered in subsequent images, offering a means to quantify both flowrate and relative vascular volume of the microvasculature in both organs and solid lesions.
- 1 March 2006
- Vol. 22 (1) , 5-13
Microbubble contrast for radiological imaging: 1. Principles.
Microbubble contrast for ultrasound imaging in radiology has finally come of age, adding entirely new capabilities to real time imaging. Following a bolus injection into a peripheral vein of as little as 0.1mL of an aqueous suspension, contrast specific imaging modes show parenchymal and lesional perfusion in real time in the major organs of the abdomen and pelvis as well as breast, thyroid and prostate. These new imaging modes exploit the unique interaction between ultrasound and microbubbles, which gives rise to nonlinear echoes that are readily distinguishable from those of tissue. Furthermore, microbubbles can be deliberately disrupted by the ultrasound imaging field. The rate at which fresh bubbles then replenish the scanplane can be metered in subsequent images, offering a means to quantify both flowrate and relative vascular volume of the microvasculature in both organs and solid lesions.
- 1 August 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 429-435
Echogenic Ovarian Foci without Shadowing: Are They Caused by Psammomatous Calcifications?
- 1 August 2002
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 429-435
Echogenic Ovarian Foci without Shadowing: Are They Caused by Psammomatous Calcifications?