Barry B. Goldberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Barry B. Goldberg has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Flemming Forsberg
Department of Radiology, Thomas Jefferson University, Philadelphia, PA, 19107, USA
3 shared publications Audun Tornes
1 shared publication- Daniel A. Merton
Jefferson Ultrasound Research and Education Institute, Thomas Jefferson University, 132 South 10th Street, Philadelphia, PA 19107
1 shared publication - Daniel A. Merton
Emergency Care Research Institute, Plymouth Meeting, PA, USA
1 shared publication - George F. Murphy
Center for Regenerative Medicine of Boston University and Boston Medical Center, Boston, MA 02118, USA
1 shared publication Ji-Bin Liu
Departments of Radiology and Diagnostic Imaging, Thomas Jefferson University, 132 S. 10th Street, Suite 763J, Main Building, Philadelphia, PA 19107
1 shared publication
Latest Publications
- 1 March 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (3) , 727-734
Sentinel Lymph Nodes in a Swine Model with Melanoma: Contrast-enhanced Lymphatic US
To determine if lymphatic channels and sentinel lymph nodes (SLNs) with and without metastases can be detected with lymphatic ultrasonography (US) after peritumoral injection of a US contrast agent and to determine if lymphatic US can be used to assess SLNs for the presence of metastatic infiltration. Six swine with 17 melanomas were evaluated. Conventional gray-scale, color flow, and gray-scale phase-inversion harmonic US examinations were performed. A US contrast agent was administered in four sites around each melanoma (1-mL total dose). Lymphoscintigraphy was followed by injection of a blue dye and then dissection. SLNs identified at lymphatic US were characterized by two readers in consensus as normal or as having metastases; results were compared with histologic findings. Statistical analyses included the sign test and the kappa statistic. Lymphatic US depicted 28 SLNs, while lymphoscintigraphy depicted 27 "hot spots" suspected of representing SLNs (including two false-positive findings). Dissection after blue dye injection helped identify 31 SLNs. There were no false-positive US findings for SLN detection. Five of six nodes not seen with lymphoscintigraphy were detected with lymphatic US. The accuracy of SLN detection was 90% (28 of 31) for lymphatic US and 81% (25 of 31) for lymphoscintigraphy (P =.29). Lymphatic US correctly depicted metastases in 19 of 20 SLNs, and five of the eight normal SLNs were correctly characterized, with an accuracy of 86% (kappa = 0.62). Detection of SLNs with lymphatic US compared favorably with that at lymphoscintigraphy. Lymphatic US can depict metastases within the SLN, which was not possible with lymphoscintigraphy.
- 1 March 2004
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 230 (3) , 727-734
Sentinel Lymph Nodes in a Swine Model with Melanoma: Contrast-enhanced Lymphatic US
To determine if lymphatic channels and sentinel lymph nodes (SLNs) with and without metastases can be detected with lymphatic ultrasonography (US) after peritumoral injection of a US contrast agent and to determine if lymphatic US can be used to assess SLNs for the presence of metastatic infiltration. Six swine with 17 melanomas were evaluated. Conventional gray-scale, color flow, and gray-scale phase-inversion harmonic US examinations were performed. A US contrast agent was administered in four sites around each melanoma (1-mL total dose). Lymphoscintigraphy was followed by injection of a blue dye and then dissection. SLNs identified at lymphatic US were characterized by two readers in consensus as normal or as having metastases; results were compared with histologic findings. Statistical analyses included the sign test and the kappa statistic. Lymphatic US depicted 28 SLNs, while lymphoscintigraphy depicted 27 "hot spots" suspected of representing SLNs (including two false-positive findings). Dissection after blue dye injection helped identify 31 SLNs. There were no false-positive US findings for SLN detection. Five of six nodes not seen with lymphoscintigraphy were detected with lymphatic US. The accuracy of SLN detection was 90% (28 of 31) for lymphatic US and 81% (25 of 31) for lymphoscintigraphy (P =.29). Lymphatic US correctly depicted metastases in 19 of 20 SLNs, and five of the eight normal SLNs were correctly characterized, with an accuracy of 86% (kappa = 0.62). Detection of SLNs with lymphatic US compared favorably with that at lymphoscintigraphy. Lymphatic US can depict metastases within the SLN, which was not possible with lymphoscintigraphy.
- 1 May 1997
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 101 (5_Suppleme) , 3139
Subharmonic imaging with gas-filled microbubbles
- 1 May 1997
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 101 (5_Suppleme) , 3139
Subharmonic imaging with gas-filled microbubbles
- 1 January 1997
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 8 (1) , 69-81
Harmonic imaging with gas-filled microspheres: Initial experiences
- 1 January 1997
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 8 (1) , 69-81
Harmonic imaging with gas-filled microspheres: Initial experiences