Daniel R. Thedens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniel R. Thedens has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Z. Faranesh
National Heart, Lung, and Blood Institute, Bethesda, USA
1 shared publication - Barry London
Division of Cardiovascular Medicine, University of Iowa, Iowa City, Iowa, USA
1 shared publication Benton Purnell
Department of Neurology, University of Iowa, Iowa City, IA 52242, USA
1 shared publication- Bryan G. Allen
Department of Radiation Oncology, University of Iowa, Iowa City, USA
1 shared publication - Chong Wang
Department of Statistics, Iowa State University
1 shared publication - Christina Meyer
Department of Biomedical Sciences, College of Veterinary Medicine, Iowa State University, Ames, USA
1 shared publication
Latest Publications
- Open Access
- 9 January 2026
- Published by Springer Nature in Acta Neuropathologica Communications
- Vol. 14 (1)
Dual targeting of iNOS and Src tyrosine kinase as a superior therapeutic strategy against soman-induced long-term neurotoxicity: multimodal biomarker, imaging, and neurobehavioral outcome analyses
Acute exposure to the organophosphate nerve agent (OPNA) soman (GD) triggers severe and persistent brain injury characterized by seizures, oxidative stress
- 9 January 2026
- Published by Springer Nature in Acta Neuropathologica Communications
- Vol. 14 (1)
Open AccessDual targeting of iNOS and Src tyrosine kinase as a superior therapeutic strategy against soman-induced long-term neurotoxicity: multimodal biomarker, imaging, and neurobehavioral outcome analyses
Acute exposure to the organophosphate nerve agent (OPNA) soman (GD) triggers severe and persistent brain injury characterized by seizures, oxidative stress
- Open Access
- 11 July 2024
- Published by MDPI AG in Tomography
- Vol. 10 (7) , 1074-1088
An Improved Postprocessing Method to Mitigate the Macroscopic Cross-Slice B0 Field Effect on Measurements in the Mouse Brain at 7TThe MR transverse relaxation rate, , has been widely used to detect iron and myelin content in tissue. However, it is also sensitive to macroscopic B0 inhomogeneities. One approach to correct for the B0 effect is to fit gradient-echo signals with the three-parameter model, a sinc function-weighted monoexponential decay. However, such three-parameter models are subject to increased noise sensitivity. To address this issue, this study presents a two-stage fitting procedure based on the three-parameter model to mitigate the B0 effect and reduce the noise sensitivity of measurement in the mouse brain at 7T. MRI scans were performed on eight healthy mice. The gradient-echo signals were fitted with the two-stage fitting procedure to generate . The signals were also fitted with the monoexponential and three-parameter models to generate and , respectively. Regions of interest (ROIs), including the corpus callosum, internal capsule, somatosensory cortex, caudo-putamen, thalamus, and lateral ventricle, were selected to evaluate the within-ROI mean and standard deviation (SD) of the measurements. The results showed that the Akaike information criterion of the monoexponential model was significantly reduced by using the three-parameter model in the selected ROIs (p = 0.0039–0.0078). However, the within-ROI SD of using the three-parameter model was significantly higher than that of the in the internal capsule, caudo-putamen, and thalamus regions (p = 0.0039), a consequence partially due to the increased noise sensitivity of the three-parameter model. With the two-stage fitting procedure, the within-ROI SD of was significantly reduced by 7.7–30.2% in all ROIs, except for the somatosensory cortex region with a fast in-plane variation of the B0 gradient field (p = 0.0039–0.0078). These results support the utilization of the two-stage fitting procedure to mitigate the B0 effect and reduce noise sensitivity for measurement in the mouse brain.- 11 July 2024
- Published by MDPI AG in Tomography
- Vol. 10 (7) , 1074-1088
Open AccessAn Improved Postprocessing Method to Mitigate the Macroscopic Cross-Slice B0 Field Effect on Measurements in the Mouse Brain at 7TThe MR transverse relaxation rate, , has been widely used to detect iron and myelin content in tissue. However, it is also sensitive to macroscopic B0 inhomogeneities. One approach to correct for the B0 effect is to fit gradient-echo signals with the three-parameter model, a sinc function-weighted monoexponential decay. However, such three-parameter models are subject to increased noise sensitivity. To address this issue, this study presents a two-stage fitting procedure based on the three-parameter model to mitigate the B0 effect and reduce the noise sensitivity of measurement in the mouse brain at 7T. MRI scans were performed on eight healthy mice. The gradient-echo signals were fitted with the two-stage fitting procedure to generate . The signals were also fitted with the monoexponential and three-parameter models to generate and , respectively. Regions of interest (ROIs), including the corpus callosum, internal capsule, somatosensory cortex, caudo-putamen, thalamus, and lateral ventricle, were selected to evaluate the within-ROI mean and standard deviation (SD) of the measurements. The results showed that the Akaike information criterion of the monoexponential model was significantly reduced by using the three-parameter model in the selected ROIs (p = 0.0039–0.0078). However, the within-ROI SD of using the three-parameter model was significantly higher than that of the in the internal capsule, caudo-putamen, and thalamus regions (p = 0.0039), a consequence partially due to the increased noise sensitivity of the three-parameter model. With the two-stage fitting procedure, the within-ROI SD of was significantly reduced by 7.7–30.2% in all ROIs, except for the somatosensory cortex region with a fast in-plane variation of the B0 gradient field (p = 0.0039–0.0078). These results support the utilization of the two-stage fitting procedure to mitigate the B0 effect and reduce noise sensitivity for measurement in the mouse brain. - Open Access
- 4 January 2023
- Published by Elsevier in Toxicology
- Vol. 485, 153424
Acute hydrogen sulfide-induced neurochemical and morphological changes in the brainstem
- 4 January 2023
- Published by Elsevier in Toxicology
- Vol. 485, 153424
Open AccessAcute hydrogen sulfide-induced neurochemical and morphological changes in the brainstem
- Open Access
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 47-14
High-energy external defibrillation and transcutaneous pacing during MRI: feasibility and safety
- 1 January 2019
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 21 (1) , 47-14
Open AccessHigh-energy external defibrillation and transcutaneous pacing during MRI: feasibility and safety
- 3 November 2010
- Published by Springer Nature
- p. 3-33
Image Acquisition for Cardiovascular and Pulmonary Applications
- 3 November 2010
- Published by Springer Nature
- p. 3-33
Image Acquisition for Cardiovascular and Pulmonary Applications