SYShan-Wei Yang

Shan-Wei Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shan-Wei Yang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-term functional outcomes of diffuse pigmented villonodular synovitis of knee

    by Ju Chun Chien, Yi Ping Wei, Chun Yu Chen, Wei Hsin Hsiang, Yuan You Wang, Wen Shan Liu, Shan Wei Yang

    Diffuse pigmented villonodular synovitis (PVNS) of knee is a rare benign disease that has a destructive clinical course. Synovectomy and adjuvant radiotherapy (RT) have been reported as treatment options but literatures reporting functional outcomes were sparse. This study aimed to evaluate the long-term functional outcomes and disease control among treatment modalities through the 22 years of experience. A single-center database was searched for patients who received synovectomy of knee with the pathologic diagnosis of PVNS. General data, treatment modalities, and recurrent status were retrospectively collected from medical records. Functional outcomes were evaluated by Western Ontario and McMaster Universities Osteoarthritis Index through phone interviews by an independent orthopedist. From January 1995 to December 2017, 24 patients with diffuse PVNS of knee were identified, including 19 receiving open synovectomy (OP) and 5 undergoing arthroscopic surgery. Adjuvant RT was performed on 14 patients with a median dose of 35 Gy (range 20–40 Gy). After median follow up of 6 years, recurrences were recorded in 10 cases. The recurrence rate was significantly lower in the OP + RT group than the OP group (8.3% vs 57.1%, P = .038). Among those with preserved knee joints, there was no significant difference in the Western Ontario and McMaster Universities Osteoarthritis Index score and stiffness score between patients in the OP + RT and OP groups. For patients with diffuse PVNS of knee, the addition of moderate-dose adjuvant RT following OP provided excellent local control while maintaining good joint function with limited treatment-related morbidity. Our study emphasized the importance of moderate dose RT in diffuse PVNS of knee joint.


  • Open Access

    Simultaneous bilateral ulnar neuropathy: an unusual complication caused by neuroleptic treatment-induced tardive dyskinesia

    by Yi-Ping Wei, Shan-Wei Yang

    Rationale: In the past decade, only a few studies have focused on simultaneous bilateral ulnar neuropathy. Patient concerns: A 54-year-old Asian male who has suffered from paranoid schizophrenia for 2 years. He reported that flexion contracture occurring over his fourth and fifth fingers on both hands appeared since six months after he started taking the antipsychotic drug. The electromyogram revealed bilateral ulnar neuropathy with chronic axonal degeneration at the elbow level. McGowan classification was performed to evaluate the severity of the ulnar nerve injury, and the patient was diagnosed with a grade 3 injury on his left hand and a grade 2 injury on his right hand. Diagnosis: Simultaneous bilateral ulnar neuropathy at the elbow, a complication caused by tardive dyskinesia in a patient under the high-dose, first-generation, antipsychotic drug. Interventions: We consulted a psychiatrist to assist in adjusting the patient's kind of the antipsychotic drug and performed the anterior transposition of ulnar nerve to avoid nerve entrapment caused by tardive dyskinesia. Outcomes: Numbness of the palms continued to regress over the following 6 months after the anterior transposition of the ulnar nerve. Regression of the involuntary movements, including repeated bending of the elbows, and shaking of both feet, was noted from the patient but was incomplete. Lessons: Two literatures concluded that parkinsonian rigidity is the main cause of simultaneous bilateral ulnar neuropathy by Sampath et al and Kurlan et al. Unlike the cases of stereotyped posture-caused neural compression reported previously, we inferred that repeated involuntary motion caused by first-generation antipsychotic drug might have been one of the causes of the patient's nerve compression.


  • A simple technique of suture loop for acute acromioclavicular joint dislocation

    by Chun-Yu Chen, Shan-Wei Yang, Kuan-Yu Lin, Yih-Wen Tarng, Jenn-Huei Renn, Chien-Jen Hsu, Kai-Cheng Lin


  • Comparison of Dynamic and Locked Compression Plates for Treating Midshaft Clavicle Fractures

    by Yu-Cheng Lai, Yih-Wen Tarng, Chien-Jen Hsu, Wei-Ning Chang, Shan-Wei Yang, Jenn-Huei Renn

    The purpose of this study was to compare the parameters of perioperative course and cost-effectiveness for patients with midshaft clavicle fractures treated by dynamic compression plates or locked compression plates. This retrospective, case-controlled study involved 54 patients with midshaft clavicle fractures who received dynamic compression plates (n=21) or locked compression plates (n=33) between January 2002 and December 2008. Indications for surgery included displacement or shortening >2 cm, comminuted fractures, and skin tenting. Patients with previous malunion, nonunion, multiple injuries of the shoulder girdle, or open fractures were excluded. Preoperative demographics showed no statistically significant differences between the 2 groups. Eighteen patients with dynamic compression plates and 28 patients with locked compression plates with postoperative follow-up >1 year were included for comparison. Statistical analyses for operative time, blood loss, complication rate, hospital stay, and union rate demonstrated no statistically significant difference between the 2 groups. The only statistically significant difference was a higher rate of plate removal requests in the dynamic compression plate group. Considering medical expenditure, locked compression plates cost 6 times more than dynamic compression plates in the authors’ institution (US $600 vs $100, respectively). Other than more plate removal requests in the dynamic compression plate group and greater expense in the locked compression plate group, dynamic compression plates and locked compression plates achieved satisfactory operative outcomes in treating midshaft clavicle fractures, with no statistically significant difference between perioperative course and eventual fracture union observed between the 2 groups.