Pieter Vanderniepen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
Pieter Vanderniepen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Manuel Dierick
UGCT-Department of Physics and Astronomy, Faculty of Sciences, Ghent University, Proeftuinstraat 86, 9000, Ghent, Belgium
2 shared publications - Camille Sonnenfeld
Brussels Photonics Team (B-PHOT), Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussel, Belgium
1 shared publication - Eli Voet
Department of Material Science and Engineering, Ghent University, Technologiepark 903, 9052 Gent-Zwijnaarde, Belgium
1 shared publication - F. Vandervoort
Belgian Nuclear Research Center (SCK·CEN), Mol, Belgium
1 shared publication - Francis Berghmans
Vrije Universiteit Brussel
1 shared publication - Gabriele Chiesura
Department of Material Science and Engineering, Ghent University, Technologiepark 903, 9052 Zwijnaarde, Belgium
1 shared publication
Latest Publications
- Open Access
A Micro-Computed Tomography Technique to Study the Quality of Fibre Optics Embedded in Composite Materials
Quality of embedment of optical fibre sensors in carbon fibre-reinforced polymers plays an important role in the resultant properties of the composite, as well as for the correct monitoring of the structure. Therefore, availability of a tool able to check the optical fibre sensor-composite interaction becomes essential. High-resolution 3D X-ray Micro-Computed Tomography, or Micro-CT, is a relatively new non-destructive inspection technique which enables investigations of the internal structure of a sample without actually compromising its integrity. In this work the feasibility of inspecting the position, the orientation and, more generally, the quality of the embedment of an optical fibre sensor in a carbon fibre reinforced laminate at unit cell level have been proven.
Open AccessA Micro-Computed Tomography Technique to Study the Quality of Fibre Optics Embedded in Composite Materials
Quality of embedment of optical fibre sensors in carbon fibre-reinforced polymers plays an important role in the resultant properties of the composite, as well as for the correct monitoring of the structure. Therefore, availability of a tool able to check the optical fibre sensor-composite interaction becomes essential. High-resolution 3D X-ray Micro-Computed Tomography, or Micro-CT, is a relatively new non-destructive inspection technique which enables investigations of the internal structure of a sample without actually compromising its integrity. In this work the feasibility of inspecting the position, the orientation and, more generally, the quality of the embedment of an optical fibre sensor in a carbon fibre reinforced laminate at unit cell level have been proven.
- 29 November 2012
- Published by Springer Nature in Rock Mechanics and Rock Engineering
- Vol. 47 (1) , 87-99
Thermal Impact on Damaged Boom Clay and Opalinus Clay: Permeameter and Isostatic Tests with μCT Scanning
- 29 November 2012
- Published by Springer Nature in Rock Mechanics and Rock Engineering
- Vol. 47 (1) , 87-99
Thermal Impact on Damaged Boom Clay and Opalinus Clay: Permeameter and Isostatic Tests with μCT Scanning