Kevin Cleary
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kevin Cleary has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Filip Banovac
Georgetown Univ. Medical Ctr. (United States)
3 shared publications Seong K. Mun
Georgetown Univ. (United States)
3 shared publications- David Lindisch2 shared publications
- Emmanuel Wilson
Children’s National Medical Center
2 shared publications Hui Zhang
2 shared publicationsRussell Taylor
2 shared publications
Latest Publications
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7625, 762523
Evaluation of nonholonomic needle steering using a robotic needle driver
Accurate needle placement is a common need in the medical environment. While the use of small diameter needles for clinical applications such as biopsy, anesthesia and cholangiography is preferred over the use of larger diameter needles, precision placement can often be challenging, particularly for needles with a bevel tip. This is due to deflection of the needle shaft caused by asymmetry of the needle tip. Factors such as the needle shaft material, bevel design, and properties of the tissue penetrated determine the nature and extent to which a needle bends. In recent years, several models have been developed to characterize the bending of the needle, which provides a method of determining the trajectory of the needle through tissue. This paper explores the use of a nonholonomic model to characterize needle bending while providing added capabilities of path planning, obstacle avoidance, and path correction for lung biopsy procedures. We used a ballistic gel media phantom and a robotic needle placement device to experimentally assess the accuracy of simulated needle paths based on the nonholonomic model. Two sets of experiments were conducted, one for a single bend profile of the needle and the second set of tests for double bending of the needle. The tests provided an average error between the simulated path and the actual path of 0.8 mm for the single bend profile and 0.9 mm for the double bend profile tests over a 110 mm long insertion distance. The maximum error was 7.4 mm and 6.9 mm for the single and double bend profile tests respectively. The nonholonomic model is therefore shown to provide a reasonable prediction of needle bending.
- 4 March 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7625, 762523
Evaluation of nonholonomic needle steering using a robotic needle driver
Accurate needle placement is a common need in the medical environment. While the use of small diameter needles for clinical applications such as biopsy, anesthesia and cholangiography is preferred over the use of larger diameter needles, precision placement can often be challenging, particularly for needles with a bevel tip. This is due to deflection of the needle shaft caused by asymmetry of the needle tip. Factors such as the needle shaft material, bevel design, and properties of the tissue penetrated determine the nature and extent to which a needle bends. In recent years, several models have been developed to characterize the bending of the needle, which provides a method of determining the trajectory of the needle through tissue. This paper explores the use of a nonholonomic model to characterize needle bending while providing added capabilities of path planning, obstacle avoidance, and path correction for lung biopsy procedures. We used a ballistic gel media phantom and a robotic needle placement device to experimentally assess the accuracy of simulated needle paths based on the nonholonomic model. Two sets of experiments were conducted, one for a single bend profile of the needle and the second set of tests for double bending of the needle. The tests provided an average error between the simulated path and the actual path of 0.8 mm for the single bend profile and 0.9 mm for the double bend profile tests over a 110 mm long insertion distance. The maximum error was 7.4 mm and 6.9 mm for the single and double bend profile tests respectively. The nonholonomic model is therefore shown to provide a reasonable prediction of needle bending.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6919
ImTK: an open source multi-center information management toolkit
The Information Management Toolkit (ImTK) Consortium is an open source initiative to develop robust, freely available tools related to the information management needs of basic, clinical, and translational research. An open source framework and agile programming methodology can enable distributed software development while an open architecture will encourage interoperability across different environments. The ISIS Center has conceptualized a prototype data sharing network that simulates a multi-center environment based on a federated data access model. This model includes the development of software tools to enable efficient exchange, sharing, management, and analysis of multimedia medical information such as clinical information, images, and bioinformatics data from multiple data sources. The envisioned ImTK data environment will include an open architecture and data model implementation that complies with existing standards such as Digital Imaging and Communications (DICOM), Health Level 7 (HL7), and the technical framework and workflow defined by the Integrating the Healthcare Enterprise (IHE) Information Technology Infrastructure initiative, mainly the Cross Enterprise Document Sharing (XDS) specifications.
- 6 March 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6919
ImTK: an open source multi-center information management toolkit
The Information Management Toolkit (ImTK) Consortium is an open source initiative to develop robust, freely available tools related to the information management needs of basic, clinical, and translational research. An open source framework and agile programming methodology can enable distributed software development while an open architecture will encourage interoperability across different environments. The ISIS Center has conceptualized a prototype data sharing network that simulates a multi-center environment based on a federated data access model. This model includes the development of software tools to enable efficient exchange, sharing, management, and analysis of multimedia medical information such as clinical information, images, and bioinformatics data from multiple data sources. The envisioned ImTK data environment will include an open architecture and data model implementation that complies with existing standards such as Digital Imaging and Communications (DICOM), Health Level 7 (HL7), and the technical framework and workflow defined by the Integrating the Healthcare Enterprise (IHE) Information Technology Infrastructure initiative, mainly the Cross Enterprise Document Sharing (XDS) specifications.
- 28 February 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (2) , 303-307
Electromagnetic Tracking–Guided Percutaneous Intrahepatic Portosystemic Shunt Creation in a Swine Model
- 28 February 2007
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 18 (2) , 303-307
Electromagnetic Tracking–Guided Percutaneous Intrahepatic Portosystemic Shunt Creation in a Swine Model
- 1 October 2006
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 17 (10) , 1671-1675
Needle Biopsy of Anatomically Unfavorable Liver Lesions with an Electromagnetic Navigation Assist Device in a Computed Tomography Environment
- 1 October 2006
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 17 (10) , 1671-1675
Needle Biopsy of Anatomically Unfavorable Liver Lesions with an Electromagnetic Navigation Assist Device in a Computed Tomography Environment
- 1 January 2005
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 01 (02) , 40
Precision placement of instruments for minimally invasive procedures using a "Needle Driver" robot
- 1 January 2005
- Published by Wiley in The International Journal of Medical Robotics and Computer Assisted Surgery
- Vol. 01 (02) , 40
Precision placement of instruments for minimally invasive procedures using a "Needle Driver" robot
- 1 January 2002
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 7 (5) , 291-299
Assessment of hepatic motion secondary to respiration for computer assisted interventions
This article reviews the published efforts to characterize hepatic motion secondary to respiration, with the specific goal of defining the limitations and potential applications of image-guided systems in percutaneous liver interventions (computer assisted interventions). Hepatic motion and deformation due to respiration remain obstacles to applying stereotactic localization techniques to the liver. Respiratory-associated hepatic motion is complex. Nine studies using diagnostic imaging or modeling are reviewed, and their findings are tabulated herein. The significant variations in their findings are discussed, including cranio-caudal translation, anterior-posterior and lateral translation, movement secondary to tissue deformation, and motion with respect to surrounding tissue. Techniques for correcting for hepatic respiratory motion are then described, including gating techniques, modeling approaches, real-time liver tracking, and magnetic tracking technology.
- 1 January 2002
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 7 (5) , 291-299
Assessment of hepatic motion secondary to respiration for computer assisted interventions
This article reviews the published efforts to characterize hepatic motion secondary to respiration, with the specific goal of defining the limitations and potential applications of image-guided systems in percutaneous liver interventions (computer assisted interventions). Hepatic motion and deformation due to respiration remain obstacles to applying stereotactic localization techniques to the liver. Respiratory-associated hepatic motion is complex. Nine studies using diagnostic imaging or modeling are reviewed, and their findings are tabulated herein. The significant variations in their findings are discussed, including cranio-caudal translation, anterior-posterior and lateral translation, movement secondary to tissue deformation, and motion with respect to surrounding tissue. Techniques for correcting for hepatic respiratory motion are then described, including gating techniques, modeling approaches, real-time liver tracking, and magnetic tracking technology.
- 24 August 2000
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 5 (3) , 180-215
Final report of the Technical Requirements for Image-Guided Spine Procedures Workshop*, April 17-20, 1999, Ellicott City, Maryland, USA
- 24 August 2000
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 5 (3) , 180-215
Final report of the Technical Requirements for Image-Guided Spine Procedures Workshop*, April 17-20, 1999, Ellicott City, Maryland, USA
- 22 May 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3035, 237-247
Challenges encountered while implementing a multivendor teleradiology network using DICOM 3.0
The ISIS Center at Georgetown University was the systems integrator for a project to design, develop, and implement a commercial off-the-shelf teleradiology system to support the US troops in Bosnia-Herzegovina. Computed radiography (CR), computed tomography (CT), film digitization (FD), and ultrasound (US) were the modalities to connect to the network. Dry laser printing and multiple display workstations were also part of the network. All systems were integrated into this network using the Digital Imaging Communications (DICOM) 3.0 standard. The modalities communicate to the workstations using the DICOM 3.0 standard and the workstations send images to the printers and other vendors' workstations using DICOM 3.0. Among the seven DICOM implementations encountered for this project, none were connected without modification to configuration files, changes or patches by vendors, or operational changes by the user. Some problems encountered include missing or ignored required data elements, padding data values, unique study identifiers to differentiate studies and images, and the use of application entity titles. This paper will discuss multi- vendor connectivity and describe the DICOM 3.0 inconsistencies which were encountered. It will also detail the problems encountered and how they were resolved, including the operational changes which were required and software fixes.
- 22 May 1997
- Published by SPIE-Intl Soc Optical Eng
- Vol. 3035, 237-247
Challenges encountered while implementing a multivendor teleradiology network using DICOM 3.0
The ISIS Center at Georgetown University was the systems integrator for a project to design, develop, and implement a commercial off-the-shelf teleradiology system to support the US troops in Bosnia-Herzegovina. Computed radiography (CR), computed tomography (CT), film digitization (FD), and ultrasound (US) were the modalities to connect to the network. Dry laser printing and multiple display workstations were also part of the network. All systems were integrated into this network using the Digital Imaging Communications (DICOM) 3.0 standard. The modalities communicate to the workstations using the DICOM 3.0 standard and the workstations send images to the printers and other vendors' workstations using DICOM 3.0. Among the seven DICOM implementations encountered for this project, none were connected without modification to configuration files, changes or patches by vendors, or operational changes by the user. Some problems encountered include missing or ignored required data elements, padding data values, unique study identifiers to differentiate studies and images, and the use of application entity titles. This paper will discuss multi- vendor connectivity and describe the DICOM 3.0 inconsistencies which were encountered. It will also detail the problems encountered and how they were resolved, including the operational changes which were required and software fixes.